Search Results for section cables
evh6-l2zk-ha-06 | Amphenol Global Search | Amphenol
FAKRA to SMA Cable Assemblies - Amphenol RF 095Z820-159-YYY; FAKRA Straight Jack to SMA Straight Jack, Z Code. 095Z820-160-YYY: FAKRA Straight Plug to SMA Straight Jack, Z Code. 095Z820-161-YYY
All Products - Amphenol
Our value-added cable assemblies include cable assemblies and harnesses, cable management products and backplane interconnect systems. Our cable solutions include coaxial cable, power cable and specialty cable. We also provide combiner/splitter products, flexible and rigid printed circuit boards, hinges and molded parts.
Issue 1 Print 5 LT93‐INCHGR‐1 InCharger INSTALLATION INSTRUCTION ...
Locate the InCharger as far away from the battery as DC cables will permit. 2. Never place the InCharger directly above the battery being charged; gases from the battery will ... See the section in this manual on Warranty and Customer Service for repair and replacement informa-tion. Disassembly Precaution Do not disassemble the InCharger .
HVC 3.6mm 2+2 pole connector - アンフェノールジャパン ...
cable type shielded, jacketed cable possible wire cross-section 6 mm² / (4mm²) ca. 45x70x35mm IP 6K9K IP 2X mating throw [mm] approx. 18 mm mechanical coding yes (neutral + coding 1-5) unmating connector by hand / locking latch development status tooled * depends on time of over current HVC 3.6mm 2+2 pole connector Rev.01_2009_07_21 voltage range
Part Search Results
OCP-Compliant Connectors & Cables Revision: NC. Featured from the Scorpion family for use as AC input connectors in OCP applications. Scorpion™ Catalog Revision: B5 24/08. The most versatile modular power/signal connector on the market offering design flexibility . SP8 End Module Update .
Tracer Rapid Connector Prototype Tool - Amphenol Aerospace
Fiber Optic Cable Assemblies ... Tracer Pattern Design Tool is available in the Documents section below. * Patent number US 11,894,649 B2. Features & Benefits: FOR NEW DESIGN PROTOTYPING: PC boards with cramped layouts that have difficulty routing traces out of traditionally
PCB Load & Torque, Inc. Model 920
Check the packing list to be sure that all equipment, transducers, cables, and other accessories were shipped with your meter. If you have any questions about this unit, its setup and operation do not hesitate to contact PCB Load & ... Section 4.0, covers taking data with the Model 920 Special Applications, Section 5.0, provides information ...
LTE 4G/5G Antennas 424x.95-780-Tx - amphenolprocom.com
The 424x Series colinear antennas are designed for LTE/GSM applications where a durable and high performance antenna is required. The centre fed dipole design and feed network gives a stable radiation pattern across a wide bandwidth, and allows tilted beam designs to be effectively employed without large pattern distortions.
Model 209C01 Miniature ICP® force sensor, 1 sec DTC, 2.2 lb comp ... - PCB
coaxial or ribbon cable without signal degradation. The low impedance voltage signal is not affected by triboelectric cable noise or environmental contaminants. Figure 1 - ICP Sensor System Schematic . Power to operate ICP sensors is generally in the form of a low cost, 2427 VDC, 2- -20 mA constant current supply. Figure 1
FOJBF-ON01S-xxM Series - HYBRIF - RFS Technologies an Amphenol Company
RFS Technologies designs and manufactures premium-quality cable and antenna solutions for wireless, public safety, distributed antenna system (DAS) and other telecom markets in North America. As an Amphenol company, we’re part of a global powerhouse in high-technology, interconnect, sensor and antenna solutions that’s enabling the electronics revolution across almost every industry.
Omni Antennas CXL 2-5SL/... - amphenolprocom.com
Consequently, the antenna shows a DC-short across the coaxial cable. CXL 2-5SL/… is a vibration-proof, lightweight, slim-line, corrosion-resistant, modern style base station antenna. ... the antenna must be mounted on the side of the mast and the top section of the glass fibre tube stabilized with a bracket.
3U VPX 56 CHANNEL 25G ETHERNET SWITCH - amphenol-aerospace.com
fiber optic cable to top of switch ctc-25g cf-901201-016 internal fiber cable cf-901200-917 external test cable 24x 25gbase-sr 24x 25gbase-sr ... section cc-cc (rotated) cavity id.094 hex drive 2 places cavity location fiber optic ribbon cables strain relief spring mt pin clamp mt front insert
Model 113B28 Platinum Stock Products; High frequency ICP ... - PCB
cable connections with shrink tubing. It is not necessary to use low-noise cable with this sensor series. In fact, an optional Model 070B09 Solder Connector Adaptor allows the use of ordinary two-wire cable if desired. 4.0 OPERATION. It is only necessary to supply the sensor with a 2 to 20 mA constant current at +20 to +30 VDC through a
g87mp | Amphenol Global Search | Amphenol
mps02-bsfa032s | Amphenol Global Search | Amphenol Search Results for n 20 252 4175 c - Amphenol N02 252 4124C - amphenol.com Part no. 252 185 Material: AIMg4.5Mn, black anodised; magnets compound-fi lled Weight: Approx. 125 g Surface pressure: Max. 20 N/mm2 Fastening torque for M4 screws: 4 Nm Operating temperature: −40…+75 °C (−40 ...
Model SYS015 | PCB Piezotronics
Model SYS015:Audiometric calibration system including 831C, 831C-AUD, AMC493B, AEC100, 377A15 1 in. microphone, ADP008A, CAL250, CCS055 case and related ac
Model 484B02 Line Powered ICP Sensor Signal Conditioner ... - PCB
other shielded cable. In some cases, it is desirable to use twisted pair and other types of 2-wire cable. 2. Connect readout device to the OUTPUT jack located on the back of the conditioner. 3. Set the MODE switch to AC. 4. Plug the supplied 3-wire line cord (PCB Model 017) into the 120V 60Hz receptacle, then press the red POWER button on.
Medical Connectors - Positronic The Science of Certainty
Some applications mandate certain connector requirements. For example, respiratory monitoring devices in patient rooms may require screw-in connectors as opposed to push-pull to ensure a secure connection. Dental applications may require connectors with outstanding moisture resistance, ergonomic performance, and cable management.
Part Search Results
Welcome to PosiBlog - the blog of Positronic. Check back often for industry news you can use and product knowledge.
97 series | Amphenol Global Search | Amphenol
97-FIBR24TRAY 4”x9” Charles Fiber Splice Tray, with dust cover, identification label and 6 cable ties 97-FIBR24HTRAY 4”x9” Charles Fiber Splice Tray, hinged, with dust cover, identification label and 6 cable ties 97-FELT1W30FT Felt for Buffer Tube Strain Relief at attachment point, 1” width, 30 ft. roll with adhesive back
Datasheet_Transmission_8mm
Wire cross-section 35 mm² Cable outlet 90° Electrical interlock (HVIL) None Secondary lock (CPA) None Shielding Yes mechanical coding None Development status B-samples available . Title: Datasheet_Transmission_8mm Created Date: 12/8/2009 5:18:20 PM ...