Search Results for solidworks student edition
cad | Amphenol Global Search | Amphenol
The PC104plus connector provides 120 contacts with a 2,0 mm footprint to the PCI BUS according PC/104. The nonstack-through version is available with solder and pressfit termination, the stack-through version with pressfit termination and contact length of 12,2 mm.
SF2921-61507-XS.PDD - svmicrowave.com
%PDF-1.6 %âãÏÓ 1 0 obj > endobj 2 0 obj > stream 2020-11-10T11:20:36-05:00 2020-11-10T11:20:21-05:00 2020-11-10T11:20:36-05:00 SOLIDWORKS 2018 SP4.0 (2018211) uuid:bcc84b5b-3894-4200-8b7b-5c223259e76d uuid:b0208707-6823-482f-a7ac-fe34f74ea1a0 application/pdf SF2921-61507-XS.PDD SV_MICROWAVE\pdm (PDMH2) SOLIDWORKS PDF Publisher endstream endobj 3 0 obj > endobj 5 0 obj > endobj 6 0 obj ...
PRODUCT DATA DRAWING
%PDF-1.6 %âãÏÓ 1 0 obj > endobj 2 0 obj > stream 2017-03-08T20:08:26-05:00 2017-03-08T20:08:26-05:00 2017-03-08T20:08:26-05:00 SOLIDWORKS 2016 SP4.0 (2016195) uuid:195b6072-fbd8-47fd-bc60-17723df90b3c uuid:bdc6e0f5-6148-433c-ab35-b2130c141526 application/pdf 8821-60021.PDD P50S\vbalaji (P50S) SOLIDWORKS PDF Publisher endstream endobj 3 0 obj > endobj 5 0 obj > endobj 6 0 obj >/ProcSet[/PDF ...
Amphenol launches the SnapEDA Viewer
With this collaboration, engineers can now find readily available digital models - such as schematic symbols, PCB footprints and 3D models - for thousands of Amphenol Communications Solutions products. Over 21,000 products are supported, including cable-to-board, D-sub, power, SFP, USB, and QSFP connectors.
Understanding Different Cable Gland Thread Types: NPT, Metric, & PG
Discover the key differences between NPT, Metric, and PG threads in cable glands. As an industrial wire and cable expert, explore how each thread type impacts cable management, sealing, and environmental protection. Make informed choices for your installations with our comprehensive guide.
Product Finder - Lutze Inc.
LUTZE Inc. 13330 South Ridge Drive • Charlotte, North Carolina 28273 • USA Phone: 704-504-0222 • Fax: 704-504-0223 • E-Mail: info (at) lutze.com
PCI Express ® Gen 5 DirectAttached™ Cable Riser - Amphenol CS
Amphenol tooled Gen 5 DirectAttached™ Cable Riser, configuration, X8 and X16 are available, and the mating interface is backward compatible with Gen 4/3/2/1. FLEXIBLE CABLE RISER WITH 32GT/S NRZ DIFFERENTIAL SIGNALING FOR NEXT-GENERATION SYSTEMS.
Protocol Manual MH-Series with CANopen Safety - temposonics.com
0x1009 Manufacturer hardware version constant 7.1 0x100A Manufacturer software version constant 7.1 0x1010 Store parameters Save all parameters read / write 7.6 0x1011 Restore parameters to default values read / write 7.6 0x1014 COB-ID EMCY message read / write 7.5 0x1017 Producer Heartbeat Time read / write 7.5
C146 10A008 600 15 Pin module for turned contacts, 8. Compar
C146 10A008 600 15 Pin module for turned contacts, 8. Comparable to PN# 9140083001
00206B44A103230525104059 - PCB
2. for us class 2258 04 - process control class 2258 84 - process control certified to u.s. standards
Table of Contents Section page no. - Amphenol CS
(4-pair version shown for reference) These modules can be combined with compatible power modules, low speed signal modules, and standalone guide pins as desired for a total stacked solution. Installation of keyed polarization pins in the end modules is optional. Figure 4: Hypothetical Backplane Header Configuration Open ended signal modules
Philmore - gemeco.com
LKG Industries, Inc.dba Philmore/Datak/Carter Craft/Pfanstiehl imports, manufactures and markets thousands of electronic accessory items for use with consumer items, in categories such as Audio, Video, Television, Telephone and Personal Computers, as well as connectors and switches for use in manufacturing.
C146 10B025 000 2 25+PE Heavy duty female contact insert fo - Amphenol Sine
25+PE Heavy duty female contact insert for stamped crimp contacts. May be engaged or disengaged when live but without electrical load. If mated or unmated under load, the load shall be reduced to 10% of the rated current.
3641-80 / 3648-80 Ethernet Routers - Charles Industries
Telecommunications Group 3641-80 / 3648-80 Ethernet Routers Guide and Web Users Manual Section 364-180-N02 Equipment Issue 1 1st Printing, April, 2006
ALDC Software Installation Quick Start - Amphenol Antenna Solutions
Setting up the ALDC software involves three steps: downloading, extracting, and then installing. ALDC software v2.0 for Microsoft Windows. The best way to obtain the latest software is to download it from the Amphenol Antennas Web site.
High Water Sensor - gemeco.com
Support. Cables & Adapters. Mix and Match Cables 1kW; Mix and Match Cables 600W; Mix and Match CHIRP Cables; Transducer Identification. B744V/VL Newer Version
SIM-N2K-N0183 USB Simulator for NMEA 2000 & 0183 - Gemeco
Get reliable marine testing with the SIM-N2K-N0183 USB Simulator from Gemeco. Compatible with NMEA 2000® & 0183, IP42 waterproof, and IEC60945 certified.
FLS6BS14N7S03 7 Position Plug, Socket, Shell Size 14, with - Amphenol Sine
MS16M12E09G5 PCB Contact - Long Version, Size 16, Gold 5µ", Female REQUEST A QUOTE MS16M23F Socket Contact, Machined, Gold Flash, Wire Range .75-1.5mm², 16-18 AWG
Snap-In Yellow Smart Sensor Cap - gemeco.com
Snap-In Yellow Smart™ Sensor Cap. Fits: ST800 Speed and Temperature Sensors. Keep up-to-date on product news and the latest offers.
Precision Battery Monitor BMV-700 - gemeco.com
Victron Energy BMV 700 single bank amp hour meter and energy monitor Monitors volts, amps, amp hours and time to go for a single battery bank. 10 meter cable, connectors and fuse included.