Search Results for srx application esp protocol policy
Smart-485 Messaging - Amphenol Sensors
Used in instrumentation for barometric pressure/weather monitoring. Detects the presence of certain gases that indicate fuel leakage. Provides liquid level feedback within the fuel system. Monitors wheel speed, engine speed and position of the engine.
Application Note AT-AN14 Acu-Trac™ Smart 485 Messaging - Amphenol Sensors
SSI’s Acu-TracTM Smart 485 ultrasonic level transducers broadcast and receive commands over a standard TIA/EIA RS-485 serial data bus enabling the transducers to communicate and share data with other modules located on the data link.
Liquid Cooling Leakage Detection Sensor Cable - amphenol-cs.com
FCI Basics offers reliable, cost-effective sensor cable solutions to detect cooling liquid leakage for applications using liquid cooling plates for thermal management. These tailor-made sensor cables uses conductive cooling liquid as a medium to form an electrical path between its electrodes, which lowers resistance and indicates liquid leakage.
Application Guide - Amphenol
NPI pressure sensor provides digital output data using the industry standard I2C protocol. Bit rates up to Bit rates up to 400 kHz are supported, compatible with the Standard-mode (Sm) and Fast-mode (Fm) standards.
Integrated IR Application Note 1 - SGX Sensortech
application. Please see paragraphs below for settings and more details on how to communicate with the INIR via the UART and the format used for the digital output string. Whether it is required to communicate with another microprocessor or a computer via the serial communication protocol both devices must have the – 2
Infrared Sensor Application Note 2 Signal Processing for Infrared Gas ...
External circuit/software will be required to perform the signal processing and to store calibration information (in non-volatile memory). See Infrared Sensor Application Notes 3 and 4. An example of each calculation is shown using typical values. Sinusoidal output at the same frequency as the lamp pulses. The amplitude of this signal decreases.
Telaire T6613/T6615 Series Development Kit - Amphenol
Take appropriate precautions to prevent damage from electrostatic discharge, mechanical stresses, and thermal abuse during installation. Please refer to ANSI/ESD S20.20-1999 for more information on preventing ESD damage, and to IPC-610 Rev D for more information on proper electronic assembly practices.
Application Note - temposonics.com
APPLICATION OVERVIEW Automatic tank gauging of propane and/or butane bullet tanks for inventory monitoring at LPG distribution terminal. Tanks are operated at approximately 21 bar (300 psi) to keep the product in a liquid state. KEY REQUIREMENTS • All electronics serviceable without blowing down the tank
1 OBJECTIVE2 2 SCOPE2 3 DRAWINGS AND APPLICABLE DOCUMENTS2 APPLICATION ...
This specification provides information and requirements for customer application of the Power TwinBlade™ I/O cable connector kits. It is intended to provide general guidance for application.
Complete End-to-End Solution - amphenolrf.com
External antennas can use either the monopole or dipole design and are typically used for higher power transmission and reception. They are ideal for applications such as Bluetooth, wireless protocols, WLAN/WWAN and IoT.
Amphenol RF Smart Grid Solutions Overview
As Electric Vehicles (EVs) and IoT applications become standard there is a growing need to modernize aging power grid infrastructure. A smart grid is a next-generation electrical grid with advanced sensor networks and automated control systems that improves the eficiency, reliability and sustainability of electricity distribution.
Quality Standards - Amphenol Aerospace
Amphenol Aerospace Quality Policy: "To satisfy the expectations and requirements of our customers by utilizing industry-leading practices in continuous improvement, automation and compliance to statutory and regulatory requirements." Have any questions? Talk with us directly using LiveChat.
Applications | Connector Solutions | Amphenol
Energy Storage Systems (ESS) store energy and stabilize electrical performance in large grid installations as well as medium commercial to residential establishments. Amphenol offers high density power connectors with small footprint that perform consistently even in rugged and harsh conditions.
6U VPX 144 CHANNEL 25G ETHERNET SWITCH - Amphenol Aerospace
embedded market to meet and exceed the demanding requirements of today’s protocols including 25G Ethernet (100GBASE-KR4) and PCIE Gen 5 (32G).
3U VPX 10G 48-Channel Rugged Ethernet Switch - Amphenol Aerospace
Precision time protocol (IEEE 1588v1/v2) support; VITA 46 3U VPX available in conduction-cooled -40- +85C environments as well as harsh vibration profiles
RFMFREP202 | Amphenol Global Search | Amphenol
Our connector and connector system solutions include fiber optic interconnect, harsh environment interconnect, high-speed interconnect, power interconnect, power distribution and busbars and radio frequency (RF) interconnect products.
Standards & Emerging Technologies - Amphenol Broadband Solutions
As stated earlier, the proliferations of new technologies and protocols has dramatically increased within the industry. The SCTE is focused on addressing topics from a standards basis, with the creation of new emphasis groups as follows: • IPS 1218-1794MHz Task Force / DOCSIS 3.1 • DDS Internet of Things [IoT], Working Group 1
AE-AN-SK-006 - SK SERIES - CARE AND MAINTENANCE - Amphenol Ardent Concepts
Amphenol Ardent Concepts makes customizable sockets that can be adjusted to fit a variety of applications. Those sockets are broken down into three main categories based on the applicable contact making the electrical connection, with those three contacts being the RC SpringprobeTM, the RC Connect-RTM and the Scrub-RTM.
FAQ - Amphenol Socapex
CAD Files Now Available for Our Rack & Panel RNJ Connectors
常见问题 | 安费诺 Socapex
IP" 表示产品对固体(第一位数字)和液体(第二位数字)的防护等级。 在安装时,Powersafe 的防护等级为 IP68。 数字 6 表示防尘和防沙。 数字 8 代表防水压力:产品可在 2 米深的水中保持 48 小时。 未接合时,我们对插座的插入/接触部分进行手指测试。 插座对应的防护等级为 IP2X。 如需了解更多信息,请联系我们的 技术支持团队 他们可以帮助您选择最适合您的电源连接器。 VG96944 标准列出了哪些材料和镀层? VG96944 标准中列出的材料和电镀层有. 海洋青铜具有出色的耐海水腐蚀和耐盐雾暴露(1000 小时)性能,是海军应用的理想选择。 如需了解更多信息,请联系我们的 技术支持团队 他们可以帮助您选择最适合您的电源连接器。 什么是 VG96944 资格认证?