Position removal tool (part number M81969/8-10 or M81969/14-04) around cable and slide tool down wire until tool tips enter rear grommet and come to a positive stop. Hold tool tip firmly against positive stop on contact, grip wire and simultaneously remove tool, contact and cable.
AT Assembly Instruction - Receptacle - Amphenol Australia
Prize up removal tool until wedge out of connector. Use the other end side of extraction tool to expand the slot and extract contacts from connector.
L-1107-v - Amphenol Aerospace
Amphenol removal tool part number 11-9170 or Daniels DRK-264-8 around cable and slide tool toward connector until tool tips enter rear grommet and come to a positive stop on contact.
10114829-10105LF | 1.25mm Wire to board | Amphenol
Amphenol is one of the leading manufacturers of MINITEK® WTB 1.25MM. Contact us today for more details of MINITEK®, part number 10114829-10105LF.
Amphenol
Contact Removal from Connector Slide integrated removal tool toward connector until tool comes to a positive stop on the contact. Grip cable and simultaneously remove contact and cable.
Amphenol Australia
AT SeriesTM connectors are a high-performance, cost-effective solution able to be used in a variety of interconnect applications: Heavy Duty, Transportation, Marine, Diagnostic, Military, Alternative Energy and Agricultural. They contain superior environmental seals and seal retention capabilities.
amphe-power-radsok-technology-catalog-amphenol-industrial
Durable, field proven cylindrical connector derived from MIL-5015 family. Threaded coupling connector with resilient Neoprene inserts, single key/keyway polarization.
NL ESOTH RW IP C F D Amphenol 22 Industry Blvd, Carrum Downs, VIC 3201 ...
and remove all burrs nl esoth rw ip c f d tolerance to be finish: material: cads file:. ' x.x'x " dimensions in do not scale x` angular amphenol australia pty.ltd, 22 industry blvd, carrum downs, vic 3201 date: date: date: part no: app'd: cale: ckd: drn: title: drawing no. size: amphenol / 1 30' 15' milimetres 5 0 14 2 refer to component mh 28 ...
Excel|Mate Mono - Amphenol Australia
6 HOW TO ORDER: PLUG HVBI 9 02R6 A F C ARD FG 25 LXXXX Shell type: 7: straight plug 9: Right angle plug Insert size: 02R6: 6mm Radsok (Rated current 120A) 03R8: 8mm Radsok (Rated current 180A) 05R10: 10mm Radsok (Rated current 250A) HVIL: A: With HVIL B: Without HVIL Insert type: F: Female contact Contact type:
Perma-Tap ® Power Cable Assembly - Amphenol CS
Perma-Tap ® power cable assembly saves space and reduces cost. The wires can be cut, stripped and terminated to customer specific lengths. The connector is press-fit to a PCB to provide a compact and secure power delivery solution. Have any questions? Talk with us directly using LiveChat.
Shield termination guide for LUTZE VFD cables
Strip the jacket with a jacket stripper. LUTZE VFD cables are designed for easy jacket removal. Strip the jacket back as short as possible. remaining jacket and cut the foil shield back. The remaining foil shield stays in contact with the braid and drain wire underneath the jacket. Cut the drain wire and braid shield back to desired length.
UNLESS OTHERWISE SPECIFIED Amphenol THIRD ANGLE PROJECTION
and remove all burrs unless otherwise specified tolerance to be finish: x.x' ± material: x.x'x " ± dimensions in do not scale x ± angular amphenol australia pty.ltd, 22 industry blvd, carrum downs vic 3201 date: date: date: part no: app'd: scale: ckd: drn: title: drawing no. size: amphenol / 1 30' 15' milimetres t.n 17/07/17 1:1 ax series ...
ATRT-100 - Amphenol Australia
Thank you! Your subscription has been confirmed. You'll hear from us soon.
Amphenol
Use tape sparingly to avoid build-up. (one complete wrap with small overlap). 1. Carefuly trim each wire pair foil shield to front edge of foil tape, to expose cable inner wires (8) as shown. 1. Carefully untwist, spread & straigten pair wires (Do not disturb foil tape wrap). 2.
Installation Instructions (General Insertion and Removal) for Size 20 ...
Installation Instructions (General Insertion and Removal) for Size 20, 22, 22D & 22M. Power terminated cables. Contacts are inserted by hand. Insert the contact assem-bly into the proper rear grommet hole. Contact must be aligned with hole and not inserted at an angle.
10168630-001HT | Minitek® 1.25mm | Amphenol
10169235-001. The FCI Basics Semi-automatic Crimping machine is designed for applications in the prototyping phase, small production quantities and can be used with the FCI Basics range of hand tools.The FCI Basics Semi-automatic Crimping machine provide and high quality thanks to the linear crimping action, portable with only 10 Kg weight and user-friendly, operation by hand.
BMA Male Flange Mount Termination, 4 Hole - SV Microwave
These products comply with the substance restrictions of the Restriction on Hazardous Substances Directive 2011/65/EU (RoHS2). The RoHS2 Directive requires that certain electrical and electronic equipment products do not contain mercury, cadmium, hexavalent chromium, PBB, PBDE, lead, DEHP, BBP, DBP and DIBP above defined thresholds.
Broadband Directional Couplers BDC1100H/V Series
Directional Couplers 1-Output BDC1100H/V Series Page 2 amphenolbroadband.com | ABS: 800-677-2288 | LATAM: 805-339-9060 | Toll Free: 800-628-4511
D38999 Series III Bulkhead Feedthrough Connectors - Amphenol Aerospace
Bulkhead Feed-Through Connectors remove the need for discrete wire termination when assembling the connector.
Amphenol
www.amphenol-industrial.com Amphenol 4 What is SurLok PlusTM? Markets The SurLok PlusTM compression lug is a field installable, high reliable alternative to common compression lugs. Using industry standard crimp, screw, and busbar termination options, thus eliminating the need to purchase special torque tools.