Search Results for tc-400-tm-x
TRIAXIAL ICP® ACCELEROMETER - PCB
Size (Height x Length x Width) 1.02 in x 1.02 in x 1.02 in 26.0 mm x 26.0 mm x 26.0 mm Weight(without cable) 0.95 oz 27 g [1] Electrical Connection Position Side Side Cable Termination 1/4-28 4-Pin Jack 1/4-28 4-Pin Jack Cable Length 5.0 ft 1.52 m Cable Type 034 4-cond Shielded 034 4-cond Shielded Mounting Through Hole Through Hole [5]
Model 350B44 ICP® Triaxial shock accelerometer, 1.0 mV/g, 5k g ... - PCB
Size (Height x Length x Width) 1.02 in x 1.02 in x 1.02 in 26.0 mm x 26.0 mm x 26.0 mm Weight(without cable) 0.95 oz 27 g [2] Electrical Connector Integral Cable Integral Cable Electrical Connection Position Side Side Cable Termination 1/4-28 4-Pin Jack 1/4-28 4-Pin Jack Cable Length 5.0 ft 1.52 m Cable Type 034 4-cond Shielded 034 4-cond Shielded
Electromagnetic/piezoelectric shaker system - Wilcoxon Sensing Technologies
Effective stiffness 3 x 810 6 lb/in (5.2 x 10 N/m) Diameter of mounting surface 0.63 in. (1.66 cm) Mounting stud, stainless steel 3/8-16 UNC Recommended screw down torque 100 lb/in (11 N/m) Temperature range 0° to +80°C Base material titanium Weight: Parts rigidly attached to structure (incl. F7) Suspended weight
Thermostatically Controlled Heat Trace Assembly - TPC Wire
Thermostatically Controlled Heat Trace Assembly is specifically designed for the de-icing of frozen pipes and valves. The 120VAC adjustable thermostat makes it easy to dial in the temperature you need up to 220°C.
Powersafe - VG96944 - 38999 Series - Amphenol Socapex
The PowerSafe connector from Amphenol Socapex is a high-performance solution designed for transmitting high power with voltages over 500V, meeting the most stringent requirements of the market regarding user safety. It is certified according to EN61984 and EN60664, ensuring that it is safe for use in even the most demanding applications. The PowerSafe connector is ideal for use in I/O power ...
Temposonics® R-Series RH Position Sensors
Temposonics® RH is a robust, high-performance rod-style sensor for installation into a hydraulic cylinder. The sensor is suitable for long-term operation under harsh industrial environments such as steel industry and metalworking plants.
Field Installable AC & DC Micro Connectors - TPC Wire
COUPLING THREAD – AC 1/2" UNF – DC M12 X 1 1. SELECTION — AC and DC, straight and 90º connectors, both male and female. 2. SEALING GROMMET — Provides a liquid tight seal to protect the connection from contamination. 3. CABLE SELECTION — Designed to fit a wide range of cord sizes from 0.158" – 0.315". 4. SCREW LOCK SYSTEM — Provides
Model 356A03 Platinum Stock Products; Triaxial, lightweight ... - PCB
Size (Height x Length x Width) 0.25 in x 0.25 in x 0.25 in 6.35 mm x 6.35 mm x 6.35 mm Weight(without cable) 0.04 oz 1.0 gm [1] Electrical Connector Integral Cable Integral Cable Electrical Connection Position Side Side Cable Termination 1/4-28 4-Pin Jack 1/4-28 4-Pin Jack Cable Length 5 ft 1.5 m Cable Type 034 4-cond Shielded 034 4-cond Shielded
TNC Straight Solder Jack 0.141-inch Conformable RG-402 Times Tflex 402 ...
RF Connector TNC Straight Solder Jack 0.141-inch Conformable RG-402 Times Tflex 402 Bulkhead Rear Mount 50 Ohm
Absolute, Non-Contact Position Sensors Operating Manual MH Series ...
1. Product description and technology Temposonics® sensors can be used in versatile mobile machines without any restriction and replace contact-based linear sensors like poten- tiometers. Highly dynamic systems are controlled safely by means of Temposonics® sensors, thus enhancing the productivity, availability and quality of the working process of the machine.
PLATINUM 4-20 MA VELOCITY TRANSMITTER - PCB
Model Number 640B01 PLATINUM 4-20 MA VELOCITY TRANSMITTER Revision: F ECN #: 49753 Performance ENGLISH SI Measurement Range 0.0 to 1 in/sec pk 0.0 to 25.4 mm/s pk [1] Output 4-20 mA 4-20 mA Frequency Range(± 10 %) 180 to 60 kcpm 3 to 1 kHz [2][3]
Model 356A32 Platinum Stock Products; Triaxial, mini (5 gm) high ... - PCB
X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above the limit requirement of GB/T 26572. Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU. MOUNTNG THREAD SEE DRAWING 5-40 A M3 X 0.50 B
Model 394C06 Platinum Stock Product Handheld shaker, 1g at 159.2 ... - PCB
X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above the limit requirement of GB/T 26572. Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU.
Data Sheet MH-Series MH4 Plus CANbus - Temposonics
3 Temposonics® MH-Series MH4 Plus CANbus Data Sheet */ Resonance frequencies excluded **/ According to calculations under use of the FKM guideline Cycles Ø 7 mm sensor rod Ø 10 mm sensor rod Dynamic pressure: < 2 × 106 pressure cycles 300 bar 350 bar Static pressure: < 2 × 104 pressure cycles 400 bar 450 bar Proof pressure: Maximum 5 minutes testing time for cylinder pressure test 525 bar ...
TRIAXIAL ICP® ACCELEROMETER - pcb.com
Size (Height x Length x Width) 0.4 in x 0.4 in x 0.4 in 10.2 mm x 10.2 mm x 10.2 mm Weight 0.14 oz 4 gm [1] Electrical Connector 8-36 4-Pin 8-36 4-Pin Electrical Connection Position Side Side Mounting Thread 5-40 Female 5-40 Female [4] All specifications are at room temperature unless otherwise specified. ...
Model 699B06 Calibration shaker Installation and Operating Manual - PCB
X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above the limit requirement of GB/T 26572. Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU. pcb.com | 716 684 0002
ICP® ACCELEROMETER Revision: J - PCB
Size (Length x Width) 0.68 in x 0.45 in 17.3 mm x 11.4 mm Electrical Connector 10-32 Coaxial Jack 10-32 Coaxial Jack Electrical Connection Position Side Side Mounting Thread 5-40 Female 5-40 Female Mounting Torque 4 to 5 in-lb 45 to 56 N-cm [4] All specifications are at room temperature unless otherwise specified.
TRIAXIAL ICP® ACCELEROMETER Revision: J - PCB
Size (Height x Length x Width) 0.4 in x 0.4 in x 0.4 in 10.2 mm x 10.2 mm x 10.2 mm Weight(without cable) 0.14 oz 4 gm [1] Electrical Connector Integral Cable Integral Cable [3] Electrical Connection Position Side Side Cable Termination 1/4-28 4-Pin Jack 1/4-28 4-Pin Jack Cable Length 5 ft 1.5 m Cable Type 034 4-cond Shielded 034 4-cond ...
Literature - Amphenol Aerospace
Amphenol Aerospace's Literature. Designed originally for use by the military, the heavy duty GT connector has become widely used in commercial, geophysical, aerospace, ground support and shipboard applications.
Model 350C23 ICP® Shock Accelerometer Installation and Operating ... - PCB
Model Number 350C23 ICP® SHOCK ACCELEROMETER Revision: D ECN #: 51341 Performance ENGLISH SI Sensitivity(± 30 %) 0.5 mV/g 0.05 mV/(m/s²) Measurement Range ± 10,000 g pk ± 98,000 m/s² pk