Temposonics II
is damped within the “dead zone” (2.5 inches in length). At the head of the transducer, two magnetically coupled sensing coils are attached to strain sensitive tapes. The tapes translate the strain pulse through coils to an electrical “return pulse”. The coil voltage is then amplified in the head electronics before it is
Part No. 550033 Rev. E - Temposonics
2 in. (50.6 mm) from the flange and minimum update time is being utilized) Transducer with: RS-422 Personality Module (RPM): ... Dead Space: 2.5 inches (63.5 millimeters) Electronics Enclosure: Designed to NEMA 6 specifications Size: 2.13 in (54.1 mm). high x 1.75 in. (44.45 mm) dia.
II e T - temposonics.com
Introduction to the Temposonics II Linear Displacement Transducer (L. n. Using the principle of magnetostriction (see Section 1.1, below), the Temposonics II LDT measures the time interval between the initiation of an interrogation pulse and the detection of a return pul.
T EMPOSONICS® T empoGuard EXPLOSION-PROOF HOUSING
Stroke-dependent Dead Zones Stroke Length Dead Zone 25 - 5000 mm (1 - 197 in.) 63.5 mm (2.5 in.) 5005 - 7620 mm (197.1 - 300 in.) 66 mm (2.6 in) All dimensions shown are for reference only. m UNITED STATES MTS Systems Corporation Sensors Division 3001 Sheldon Drive Cary, NC 27513 Tel: 800.633.7609 Fax: 919.677.0200 Web: www.mtssensors.com Email:
Hermetic Bulkhead RF Adapters - SV Microwave
SV Microwave's newly released Hermetic Bulkhead RF Adapters for inside-of-the-box applications. Available in SMA, 2.92mm, SMP and SMPM series.
Temposonics II Ordering Guide
Temposonics II transducers have a 2.5 inch dead zone at the tip. Previous versions of the Temposonics transducer had either a 5 inch or a 7 inch dead zone; please consider the overall length requirement in your application. Build-to-order units range from 1 to 300 inches, in 1/10th inch increments.
UE62Q1626022C2 | OSFP | Amphenol
Amphenol is one of the leading manufacturers of OSFP connectors. Contact us today for more details of OSFP, part number UE62Q1626022C2
TFOCA II | Deployable Fiber Optics Connectors
In 1999, Amphenol Fiber Systems International (AFSI), in collaboration with the United States Army Communications-Electronics Command (CECOM), designed the “next generation” deployable fiber optic connector for the emerging “knowledge-centric warfare communication” requirements of the future battlefield.
Data Sheet *%ZLWKWKUHDGHG DQJH$QDORJ - Temposonics
the in-house manufactured waveguide forms the basis for precise ... Dead zone 63.5 (2.5) Magnet Magnet Magnet 2.5 (0.1) Ø 25.4 (Ø 1) A/F 55 A/F 55 A/F 55 Controlling design dimensions are in millimeters and measurements in ( ) are in inches. Temposonics® GB with threaded flange Analog 5
90312-008LF | Minitek® 2.00mm WTB | Amphenol
Amphenol is one of the leading manufacturers of minitek 2.00mm - crimp to wire. Contact us today for more details of minitek , part number 90312-008LF.
Protimeter MMS2 | 4 in 1 Moisture Meter with Infrared
Its ergonomic, 4-in-1 design allows one-handed operation to measure moisture on and below the surface as well as ambient air humidity.
551166A R Series RD4 Flex - Temposonics
in the cylinder end cap to house the head of the sensor rod. Also, a hole going through the end cap is needed to channel the interconnection cable to the electronics housing that mounts on the side of the end cap. Proper design and careful sensor installation is required to assure ... Dead Zone 63.5 mm (2.5 in) 36.5 mm (1.44 in.) Electronics
Data Sheet GB-M / GB-T Analog - Temposonics
the in-house manufactured waveguide forms the basis for precise measurements. The position magnet is mounted on the moving ma-chine part and travels non-contact over the sensor rod with the built-in ... Dead zone 63.5 (2.5) Magnet Magnet Magnet 2.5 (0.1) Ø 25.4 (Ø 1) A/F 55
Data Sheet HIGH PRESSURE HOUSING (HPH) - Temposonics
Dead zone *64 mm (*2.52 in.) Zone 1 Zone 0 * Stroke length > 5000 mm (200 in.) = 66 mm (2.61 in.) M5 Magnet M18×1,5-6g ¾" 16 UNF-3A Ø 64 mm (Ø 2.52 in.) Ø 85 mmØ 85 mm (Ø 3.45 in.) Ø 69 mm (Ø 2.72 in.) 86 mm (3.41 in.) 25 mm (1 in.) Short top 158 mm / Long top 198 mm (6.22 in / 7.81 in.) Ø 64 mm (Ø 2.52 in.)
Data Sheet R-Series V RM5 PROFINET (Doc Part No. 552118)
Shock test 100 g/6 ms, IEC standard 60068-2-27 Vibration test 10 g/10…2000 Hz, IEC 60068-2-6 (excluding resonant frequencies) EMC test Electromagnetic emission according to EN 61000-6-3 Electromagnetic immunity according to EN 61000-6-2 The RM5 sensors fulfill the requirements of the EMC directives 2014/30/EU, UKSI 2016 No. 1091 and TR CU 020 ...
Staying in time – Data acquisition and transmission with the R-Series V ...
With an asynchronous measurement, the dead time varies over a wide range. A constant dead time allows an exact assignment of the measurement to a point in time and is an essential requirement for motion control applications. The dead time is minimized in synchronous mode (Fig. 5). What is the parameter "Jitter Window"?
Data Sheet R-Series V RDV PROFINET (Doc Part No. 552139)
2 Temposonics® R-Series V RDV PROFINET Data Sheet Fig. 1: Time-of-flight based magnetostrictive position sensing principle MEASURING TECHNOLOGY The absolute, linear position sensors provided by Temposonics rely on the company’s proprietary magnetostrictive technology, which can
Data Sheet *% 6HULHVZLWKSUHVVXUH W DQJH$QDORJ - Temposonics
Temposonics® GB with pressure-fit flange Analog Data Sheet I 6 I FREQUENTLY ORDERED ACCESSORIES – Additional options available in our Accessories Guide 551444 Position magnets Ø 32.8 (Ø 1.29) Ø 23.8 (Ø 0.94) Ø 13.5 (Ø 0.53) Ø 4.3 (Ø 0.17) 60° 140°
T RSERIES - Temposonics
Temposonics R Series sensors offer modular construction and non-con-tacting magnetostrictive technology. Two application housings are avail-able: rod-style (Model RH) and pro-file-style (Model RP).
TEMPOSONICS III
SPECIFICATIONS PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) Resolution: 16 bit or 0.025 mm, whichever is greater Non-Linearity: < ± 0.02% of full stroke or ± 0.05 mm, whichever is greater Repeatability: < ± 0.001% of full scale or ± 0.0025 mm, whichever is greater Hysteresis: < 0.004 mm Outputs: Voltage: 0 to 10 Vdc or +10 to 0 Vdc *; Minimum load ...