Search Results for tvp07dz-15-35p
B A2 - Amphenol Sine
49.15 8.5 recommended panel cutout type 1 17.23 34.45 28.0 14.25 2x Ø5.80 5.68 internal sealing suface finish to be or better3.2 4x r8.0 2x r1.3 recommended panel cutout type 2 49.15 17.23 34.45 28.0 internal sealing suface finish to be or better3.2 4x r8.00 14.0 14.0 7.1 0.13 0.13 2x r1.1 49.2 64.7 38.3+0.30-0.70 shown with end cap
Accelerometers / Vibration Sensors | PCB Piezotronics
PCB ® manufactures sensors used by design engineers and predictive maintenance professionals to test and measure vibration, pressure, force, acoustics, load, and shock in research and development as well as industrial applications.. Divisions of PCB
711 Series Single/Multi Way - Amphenol-Air LB
6 Terminating Contacts (for use with multi way connectors) Pin terminator 3KΩ±5% - 711-0176-3K also 77Ω±1% Socket terminator 3KΩ±5% - 711-0125-3K also 77Ω±1% Dummy Contact and Seal Plug Kit (for use with multi way connectors) Pin 711-0174-P
PM2.5 In-Cabin Particulate Dust Sensor | Telaire
15 sec @ T63.2: Signal Update: Every 1 second: Signal Averaging: Rolling 20 second average: Warm Up Time <5 sec (operational) 1 minute (maximum accuracy) Operating Conditions-40°C to 80°C: Storage Conditions-40°C to 85°C: Guaranteed Performance Range-20°C to 60°C: Output: Lin bus 2.2 Filtered PM2.5, sensor temp: Protection:
Amphenol
Amphenol is one of the world’s largest providers of high-technology interconnect, sensor and antenna solutions. Our products Enable the Electronics Revolution across virtually every end market including Automotive, Broadband Communications, Commercial Aerospace, Defense, Industrial, Information Technology and Data Communications, Mobile Devices and Mobile Networks.
ICP® PRESSURE SENSOR - PCB
Sensitivity(± 15 %) 500 mV/psi 72.5 mV/kPa Maximum Pressure(step) 100 psi 690 kPa Maximum Pressure(static) 500 psi 3,448 kPa Resolution 0.07 mpsi 0.00048 kPa [1] Resonant Frequency ≥ 40 kHz ≥ 40 kHz Rise Time ≤ 12 µ sec ≤ 12 µ sec Low Frequency Response(- 5 %) 0.5 Hz 0.5 Hz
General Purpose Piezoelectric Accelerometers - PCB
Piezoelectric accelerometers offer tremendous versatility for shock and vibration measurements. These rugged sensors can withstand adverse environmental conditions.
Vibration monitoring FAQs - Wilcoxon Sensing Technologies
1. Is a wider sensitivity tolerance bad, such as ±15%? No. If trending on vibration levels, then a wider tolerances such as ±15% provides adequate, cost-effective information for a successful monitoring program. Also, nearly all data collection boxes, analyzers and acquisition systems have the ability to enter the exact sensitivity of a sensor.
PCB Piezotronics | Measure vibration, pressure, force, and more
PCB Piezotronics | Measure vibration, pressure, force, and more
Mil-Spec Contacts | Products | Amphenol Aerospace
MIL-DTL-38999 Series III, II, I Contacts 38999 Application Tools 38999 Assembly Instructions 26482 Contact Information 26482 Assembly Tools 83723 Contact Information 83723 Assembly Tools MIL-DTL-83723 (Pyle) Contacts and Tools Class L Contact Information Class L Installation Instructions
D38999 Series III Hermetic Connectors - Amphenol Aerospace
Amphenol Tri-Start MIL-DTL-38999 Series III Hermetic Connectors offer the highest performance capabilities for both general duty and severe environment applications and meet or exceed MIL-DTL-38999 Series III requirements.
Industrial plugs and sockets Easy & Safe
3 Grey AC 216BS1 2CMA193293R1000 10 0.15 Yellow 100...130 50 and 60 216BS4 2CMA193289R1000 Blue 200...250 216BS6 2CMA193290R1000 Red 380...415 216BS9 2CMA193291R1000 Grey transf. 216BS12 2CMA193292R1000 3P+E 4 Grey AC 316BS1 2CMA193303R1000 10 0.19 Yellow 100...130 50 and 60 316BS4 2CMA193296R1000
EBY Pluggable Headers - EBY Electro
15 Amps, 300VAC Dual Level, Horizontal, Closed. HC1508M-XX-520 Pluggable Headers HC1508M-XX-520 Centerline 0.200" (5.08mm) 20 Amps, 300VAC Mounting Flanges. HC1768MN Pluggable Headers HC1768MN Centerline 0.300" (7.62mm) 32 Amps, 300VAC with Mounting Flanges. HM350 Pluggable Headers ...
PORTABLE VIBRATION CALIBRATOR - PCB
Velocity Amplitude Range (50 Hz, 10g payload) 0 to 20 ips pk. 0 to 500 mm/s pk. Displacement Amplitude Range (50 Hz, 10g payload) 0 to 150 mils pk-pk
EU-TYPE EXAMINATION CERTIFICATE - Amphenol Australia
13-2, 15-2, 17-2, 13-4, 15-4, 17-4 Ex d IIC T6 Gb Ex tb IIIC T80°C Db -40 to +40 See note A 70 90 Ex d IIC T5 Gb Ex tb IIIC T95°C Db -40 to +55 See note A 70 90 Ex d IC T4 G b Ex tb IIIC T130°C D -40 to +55 >1135-1490 A 135 13-3, 15-3, 17-3 Ex d IIC T6 Gb Ex tb IIIC T80°C Db -40 to +40 See note A 70 90
Amphenol
Amphenol® 97 Series Connectors are UL recognized and CSA recognized. AMPHENOL CORPORATION Amphenol Industrial Phone: 888-364-9011 191 Delaware Avenue
Telaire T8000-R Series
±1°C from 15-30°C (±1.8°F from 59 to 86°F) Power Supply Requirements 18-30 VAC RMS, 50/60 Hz, or 18 to 42 VDC, polarity protected *AHRAE — regulation 62 states maximum indoor CO 2 level of 1000 ppm Power Consumption Typical 0.7 W at nominal voltage of 24V AC RMS Temperature Dependence 0.2% FS per °C (±0.11% per °F) Stability
MINIATURE ACCELEROMETERS - PCB
0.15 ounces (4.2 grams). The TEDS feature self identifies these accelerometers and describes the type, operation and their attributes making them extremely easy for the operator to track. Ground isolated (J) models reduce electrical noise and potential for ground loops. High temperature (HT) models have extended
TFOCA-II 4 Channel - Amphenol Fiber Systems International (AFSI)
AFSI designed its patented TFOCA-II® connectors to survive the harshest battlefield conditions imaginable. The heart of the TFOCA-II® family of deployable fiber optic connectors centers on the TFOCA-II® sealed free-floating termini. The robust termini design enables TFOCA-II® connectors to seal against high humidity and moisture conditions while allowing full axial and orbital movement of ...