Search Results for uses of non-magnetic materials
UHF Connectors - RF Connectors - Amphenol RF
Originally intended for use as a video connector in radar applications, UHF coaxial connectors are general purpose units developed for use in low frequency systems from 0.6 - 300 MHz. Invented for use in the radio industry in the 1930’s, UHF is an acronym for Ultra High Frequency because at the time 300 MHz was considered high frequency.
12T KVA IsoTransformer INSTALLATION INSTRUCTIONS & OWNER’S MANUAL
120-Volt branch circuit breakers are permitted to use single-pole breakers in the ungrounded current-carrying conductors. The shore grounded (green) conductor is connected from the shore power cable and the boat’s power inlet directly to all non-current-carrying parts of the AC electrical system including the transformer case and to the
MD035 accelerometer magnetic mounting base for rounded surfaces
Two-footed accelerometer magnetic mounting base for use on rounded surfaces, two-pole magnet, 35 lb force, 1/4-28 tapped hole, non-isolated, 1" diameter. Magnetic bases are a quick and convenient option for walkaround applications, and are often used on large machinery. They can be quickly attached and removed on both flat and curved surfaces.
Kaye ValProbe Standard Logger
Logger Material. Stainless Steel 316L and Peek. Battery Field replaceable – 3.6V Lithium. Sampling Rate. 1 sec to 12 hours. Data Storage 10,000 Samples retained in non-volatile memory. Real-Time Clock Accuracy < 15sec / day. Calibration NVLAP/DAkkS Calibration. Verification. Automated User
Data Sheet HIGH PRESSURE HOUSING (HPH) - Temposonics
application, generates a magnetic field at its location on the waveguide. A short current pulse is applied to the waveguide. This creates a momentary radial magnetic field and torsional strain on the waveguide. The momentary interaction of the magnetic fields releases a torsional strain pulse that propagates the length of the waveguide. When the
MD050 accelerometer magnetic mounting base for rounded surfaces
Two-footed accelerometer magnetic mounting base for use on rounded surfaces, two-pole magnet, 55 lb force, 1/4-28 tapped hole, non-isolated, 1.25" diameter. Magnetic bases are a quick and convenient option for walkaround applications, and are often used on large machinery. They can be quickly attached and removed on both flat and curved surfaces.
2M Series Performance Specifications - amphenol-aerospace.com
Magnetic Permeability 2 μ maximum. EIA-364-54 ENVIRONMENTAL Operating temperature -65° to +175°C Water immersion, mated No evidence of water penetration into mated connectors. ≥100W insulation resistance. MIL-STD-810F Method 512.4 1 meter immersion 1 hour Water immersion, open face panel mount receptacles with non-removable printed
Model 8180-CU00A single-channel TELEMETRY Control unit ... - PCB
The inductive head should be fastened to a non-metallic plate or bracket. If a metallic bracket is used the stator should be isolated from the metal by more than 5 mm of a non metallic material such as rubber or plastic. Mounting the stator near or on metal could produce unnecessary warming of the stator head and cause damage to the system.
MMCX Plug to MMCX Jack Adapter 50 Ohm Straight | 262136
Contact Material: Beryllium Copper: Export Control Classification Number: EAR99: Frequency (Max GHz) 6: IP Rating: Not Rated: Impedance (Ohms) 50: Insulator Material: PTFE: Isolated: No: Low PIM: No: Mil Qualified: Not Mil Qualified: Non Magnetic: No: Orientation: Straight: Panel Mounting Feature: Not Applicable: Temp (Max Degrees Celsius) 165 ...
Vibration monitoring considerations in high EMI environments
High voltage, high electric and magnetic fields can cause strong EMI, vibration sensors mounted in industrial environments should be able to operate without damage or risk of degradation. ... Arcing can occur when high potential is separated by a non-conductive material, like in a capacitor, and the breakdown voltage is exceeded. HV sensors are ...
What Torque Specification do I apply? - Amphenol RF
Please note the differences in thread types and the Hex Nut materials that are used. Different thread types can have the same material but yield a different torque spec. For torque specs not included, Contact Technical Support .
TNC Straight Clamp Jack RG-174 RG-188 RG-316 Times LMR-100A Bulkhead ...
Body Material: Brass: Cable Type (Terminates to) RG-174, RG-188, RG-316, Times LMR-100A, Belden 7805A, Belden 8216, Belden 83269, Belden 83284, Belden 84316, Times RG-174LL, Shikoku 1.5DS-QFB-TA, Sumitomo 1.5DS-GXC-SP, Leoni DACAR 462, Leoni DACAR 462-2 ... Non Magnetic: No: Orientation: Straight: Panel Mounting Feature: Bulkhead - Rear Mount ...
Mounting hardware and accessories - Wilcoxon Sensing Technologies
Anodized aluminum, non-conductive coating prevents ground loops Anodized aluminum, non-conductive coating prevents ground loops Anodized aluminum, non-conductive coating prevents ground loops. Use with 731A sensor QB-1 sensor adaptor QP-1 mounting pad QP-2 cementing pad Diameter 1.0 in Mount 1/4-28 1/4-28 tapped hole base flat base Mounting torque
Microsoft Word - LT93-ISOBOO-2 PR2 11-3-14.docx
use the Iso-Boost™’s isolation transformer. Power is transferred from the shoreside electrical system to the boat’s electrical system by magnetic coupling. This means there is no direct electrical connection between the earth-grounded shore AC power and boat AC power. The shore grounding conductor is connected to a shield that is
Cable Assemblies | Products - Amphenol
These cable assemblies are used for data transfer and power charging. Amphenol's Charger Cable Solutions provide highly flexible customized connection solutions from standard USB 2.0/3.0 to the device side with Pogo pins or Spring. The connection mechanisms include magnetic, buckling, clamping, cradle, etc.
RP-BNC Connectors - Amphenol RF
The Bayonet Neill Concelman (BNC) connector was developed by Paul Neill of Bell Labs and Amphenol's own, Carl Concelman, and was named after both inventors and the innovative bayonet locking mechanism that the connector utilizes. The BNC connector was originally designed for military applications but is mostly used in the broadcast market today.
780FM-2-J88C Integral cable accelerometer for walkaround vibration ...
Integral cable accelerometer, compact, for walkaround vibration monitoring, 100 mV/g sensitivity, ±15% sensitivity tolerance, top exit 6' coiled integral cable with BNC connector for use with portable vibration data collectors, magnetic mounting base
Miniature Rugged Connector Series - amphenol.com.au
Non-magnetic Yes Environmental Operating Temperature Range -55°C to +125°C Temperature Endurance 250 hours +125°C Sealing (mated and unmated) IP68, 1 hour at 2 metres* ... material and finished in the latest RoHS compliant, Cadmium Free, Black Zinc Nickel plating finish. Typical weight savings are as much as 50% compared to standard Terrapin
Absolute, Non-Contact Position Sensors Operating Manual MH Series ...
1. Product description and technology Temposonics® sensors can be used in versatile mobile machines without any restriction and replace contact-based linear sensors like poten- tiometers. Highly dynamic systems are controlled safely by means of Temposonics® sensors, thus enhancing the productivity, availability and quality of the working process of the machine.
Absolute, Non-Contact Position Sensors Data Sheet G-Series Analog or ...
magnetic and elastic transport properties of the materials crystal lattice. This affect is typically on the scale of a few parts per million. It is quasi linear with the material‘s magnetization, may be positive or negative, and reaches a maximum at magnetic saturation. It is reversible, but exhibits a hysteretic affect if the magnetization ...