Search Results for www.espv.return system
Pressure/Temperature Real-Time Data Logger - KAYE
Il registratore di pressione / temperatura ValProbe RT offre un'ampia gamma di temperature da 0 ° C a 140 ° C ed è una soluzione unica per la misurazione di pressione e temperatura per pressioni fino a 5 bar assolute. La tecnologia RTD offre precisione di misurazione e il nuovo design elettronico del logger garantisce una lunga durata della batteria.
NEW - BoardLock™ Family - Amphenol Australia
Amphenol Sine Systems’ BoardLock™ Family combines flanged or flangeless, 180° straight or 90° right angle pin-oriented, wire-to-board versatility with the proven reliability of the A Series™ environmentally-sealed thermoplastic connection system with a maximum current rating up to 100A.
FS1K3820ZA40|EXTREMEPORT QSFP+|Amphenol
Amphenol is one of the leading manufacturers of ExpressPort QSFP. Contact us today for more details of ExpressPort QSFP, part number FS1K3820ZA40
150WXS WeatherStation® Instrument - Airmar
Certs And Standards: CE, IPX4, RoHS, IEC61000-4-2, IEC60945, IEC60950_1C, IEC60950_22A, EN55022, EN55024, EN14982
Charles Universal Broadband Enclosure CUBE-PM63912 and CUBE-PM63915 ...
opened. Figure 4 shows the dimensions of the thermal system (if equipped). See Table 2 for a list of all models. The supplemental documents that ship with each model include component views. 29.00 27.50 32.00 32.00 74.00 (8) Ø2.50 KNOCKOUTS (6 ON OPPOSITE SIDE) (5) Ø2.50 KNOCKOUTS (4) Ø2.50 KNOCKOUTS (2) Ø1.37 KNOCKOUTS DOOR OPEN 90º DOOR ...
Amphenol CS-DSPMHD15MF-002.5 15-Pin (HD15) Premium HD D-Sub Cable ...
Buy 2.5ft Amphenol CS-DSPMHD15MF-002.5 Cables Direct from the Factory at Cables on Demand. 15-pin (HD15) Premium Male/Female Double Shielded High Density D-Sub Cables by Amphenol offer extreme resilience in installations subjected to high EMI/RFI interference such as medical, industrial, military, avionics, and broadcast facilities. Each fully assembled Premium HD D-Sub Cable integrates ...
Standards Enabling the Automotive Industry - Amphenol CS
Standards and specifications from various organizations provide a guideline to manufacturers in measuring the quality of their product. This helps to ensure end customers are purchasing a trustworthy and high performance product. Standards are increasingly important in the Automotive Industry.
Machined, Stamped & Formed and RADSOK® Precision Connector Contacts
www.amphenol-sine.com www.amphenol-sine.com Machined, Stamped & Formed and RADSOK® Precision Connector Contacts Amphenol Sine Systems is your trusted component source for precision connector contacts designed for increased reliability and reduced cost.
Application guide for PC420V series - Wilcoxon Sensing Technologies
If either system used a meter or digital system with a full-scale input voltage of 5.0 Volts DC, we would have to convert the current to a voltage of 5.0 Volts. Applying Ohms law results in a resistor of 250 Ohms for a 20 mA loop and one of 100 Ohms for a 50 mA loop. However, the
Amphenol All Sensors Products | All Sensors
Pressure Max: 60 Units: IN H2O Operating Temperature:-25 to 85 C Supply Voltage: 3.3 VS Honeywell PN: Supply Voltage: 3.3 VS
111 | Amphenol Global Search | Amphenol
Amphenol LTW NMEA 2000 Connector System is specifically designed to meet NMEA 2000 protocols and standards. The IP68-rated family of multi-port, standard and metric circular connectors, sensor and actuator cables, and elbow joints are ideal for connecting marine electronic equipment and display units within ships and boats.
HD-BNC Connectors - Amphenol RF
The HD-BNC product line delivers both true 50 and 75 ohm performance in a footprint 4 times smaller than traditional BNC connectors. Using the same cable prep and termination specifications of legacy broadcast connectors makes adopting HD-BNC seamless.
MIL-DTL-83723, Series III, Pyle B - Amphenol Aerospace
83723 III 20 Contact Amphenol Aerospace for more information at 800-678-0141 • www .amphenol-aerospace .com Pyle B MIL-DTL-83723, Series III, Pyle ® Sq. Flange Receptacle, Threaded - Quick Reference SQUARE FLANGE RECEPTACLE THREADED Military: M83723/82 with Sockets, Classes G, K
Pump Sensors | PCB Piezotronics
Hermetic sensors used for protection against pump cavitation, recirculation, and resonance. There are dozens of different types of pumps and a seemingly endless list of applications but industrial accelerometers can often help the maintenance professional to diagnose sometimes tricky issues with pump operation.
PS SERIES PSD28V16CBPC-X - Amphenol Socapex
Protection is active, preventing from the short to spread through system. See short circuit curve. Capacitive Load Charge 3mF @ Vin = 33V, I LIM = 125A Option to charge much greater capacitance, consult factory. Paralleling Outputs Outputs can be paralleled to achieve one common channel with large current limit Control & Indication Ethernet
SSI Technologies - Application Note FT-AN6
(OBD) system. The OBD system usually suports p warning actions (low urea level light and de-rating of engine performance) and emissionlimit enforcement actions (engine shutdown or blocking engne riestart after shutdown). The Fluid-Trac® level sensor is an optimal choice for urea tak anpplications. Fluid-Trac® is a noncont-act
Careers - Casco Automotive Group
Creativity and Innovation. Casco encourages employees to come up with creative solutions to resolve customer issues. Through these unique challenges, Casco employees are able to deliver exceptional customer service by presenting creative and innovative ideas or solutions to meet the customer’s needs.
4-20 mA vs. IEPE vibration sensors for control systems
The most common option in plants with PLC/DCS/SCADA systems is using a 4-20 mA sensor which outputs directly to the control system, just like any of the temperature, pressure, or flow sensors already in place in these plants. 4-20 mA sensors provide continuous trend data, making it easy to track changes in overall vibration levels.
Apex Galley Connector - Amphenol PCDAmphenol PCD
Crimp termination connection system with 3 Power (10 AWG) & 3 Control (16 AWG) Blind-Mate Connection: Designed with a key feature to enable quick and simple mating. Tested to MIL-STD 1344 and EN 2591 standards; high frequency mating. Configurable to PCB contacts, plating options available. Smooth, low insertion force to mate connector
Endevco Signal Conditioners | PCB Piezotronics
The new family of signal conditioners are intended for two types of dependable piezoelectric charge output accelerometers; single ended and differential.