Search Results for 10-70506-24
Data Sheet MH-Series MH Analog - Temposonics
3 Temposonics® MH-Series MH Analog Data Sheet */ Resonance frequencies excluded **/ According to calculations under use of the FKM guideline Cycles Ø 7 mm sensor rod Ø 10 mm sensor rod Dynamic pressure: < 2 × 106 pressure cycles 300 bar 350 bar Static pressure: < 2 × 104 pressure cycles 400 bar 450 bar Proof pressure: Maximum 5 minutes testing time for cylinder pressure test 525 bar 625 bar
LÜTZE Relays
10. Contact resistance Is indicated as total resistance from the resi-stance of the contacts and the resistance of the connections and contact springs. The contact resistance is measured using the vol-tage drop method set out below. Monostable relay Bistable relay with 1 coil Bistable relay with 2 coils
Model RHM240A03 Industrial dynamic strain sensor, ICP® quartz ... - PCB
Industrial dynamic strain sensor, ICP® quartz, 10 mV/microstrain, +/300 microstrain range, M6 x 1 thd, RoHS compliant Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: [email protected] Web: www ...
Model 113B23 | PCB Piezotronics
Model 113B23:High frequency ICP® pressure sensor, 10k psi, 0.5 mV/psi, 0.218" dia. diaphragm, accel. comp.
PT SERIES - Amphenol-Air LB
Connectors – Complete overview 10 - 11 Cross-reference table (PT-MIL-VG) 12 - 13 PT Series (solder connection) 14 - 25 PT Series (solder connection, hermetic) 26 - 29 PT-GS Series (PCB connection) 30 - 37 PT-WW Series (wire-wrap connection) 30+ 38 ... 10 10-7 – – – – 10 10-98 90 180 24 270
ICP® PRESSURE SENSOR - PCB
Sensitivity(± 10 %) 1.0 mV/psi 0.15 mV/kPa Maximum Pressure 15,000 psi 103,000 kPa Resolution 20 mpsi 0.14 kPa [2] Resonant Frequency ≥ 500 kHz ≥ 500 kHz ... For +10 volt output, minimum 24 VDC supply voltage required. Negative 10 volt output may be limited by output bias. [2]Typical.
Model 003C05 Low-noise coaxial cable, blue TFE jacket, 5-ft, 10 ... - PCB
Low-noise coaxial cable, blue TFE jacket, 5-ft, 10-32 coaxial plug to BNC plug Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: [email protected] Web: www.pcb.com. Manual 21354 Rev E ECN 50523 ...
Fiber Optic Systems for Broadcast & HDTV Broadcast
We specialize in harsh environment fiber optic connectors and cable assemblies to provide the best solution for your broadcast application.
Amphenol
Amphenol® 97 Series Connectors are UL recognized and CSA recognized. AMPHENOL CORPORATION Amphenol Industrial Phone: 888-364-9011 191 Delaware Avenue
Data Sheet R-Series V RH EtherNet/IP - Temposonics
4 Temposonics® R-Series V RH EtherNet/IP™ TECHNICAL DRAWING Fig. 3: Temposonics® RH5 with ring magnet Controlling design dimensions are in millimeters and measurements in ( ) are in inches RH5-M/S-A/-V – RH5 with threaded flange M18×1.5 or ¾"×16UNF (connection type D58)
M28840
24 22 20 26 24 22 32 30 28 Acceptable Wire Size Max. Outside Dia. of Finished Wire Min. Current Rating (Max.) Size # 20 contact 20AWG 7.5A, 22AWG 5.0A, 28AWG 1.5A, 30AWG 1.0A Test Voltage (Dielectric Withstanding Voltage) Insulation Resistance Contact Resistance Operating Temperature Fluid Immersion Shock Vibration Magnetic Permeability Per SAE ...
A3 - RELEASE NEW DRAWING FORMAT 10/23/13 DRP - Amphenol Sine
D.PARKS 10/23/13 NONE OF: SH: REV: DWG NO: TITLE: REV DESCRIPTION DATE REVISIONS ECO BY APPR 1 1 A3 AT04-08PB-PMR7G AT,8 PIN RECEPT. W/ FLANGE,GASKET & REDUCED DIA. ... Gold-plated 1622-24 Machined AT60-202-16141-22 Male Contact - Pin, Nickel-plated 16 22-24 Machined AT62-201-16141-22 Female Contact - Socket, Nickel-plated 1622-24 Machined ...
Model 356A16 | PCB Piezotronics
Model 356A16:Platinum Stock Products; Triaxial, high sensitivity, ceramic shear ICP® accel., 100 mV/g, 0.5 to 5k Hz, aluminum hsg, 4-pin conn.
Sensor Mounting Pads | PCB Piezotronics
Sensor Mounting Pads. Maximize the accuracy and repeatability of your vibration monitoring with sensor mounting pads from IMI Sensors. Designed for critical measurement consistency, these pads ensure that sensors are always positioned identically for reliable data collection.
High POWER - Amphenol Aerospace
4 #10-32-UNF 0.300 #12-28-UNF 0.320 0.332 0.225 0 1/4-28-UNF 0.450 5/16-24-UNF 0.480 0.469 0.356 *Except for PC tail and Busbar, Size 12 and 16 contacts are solder cup for backfilled connectors, crimp for non-backfilled connectors. CONTACT FACTORY FOR BUS BAR TERMINATION OPTIONS
Temposonics
10 12 9 16H8 17 24 Ø 4.4 17 24 Ø 4.4 40 mm 51 mm 58 mm Ø24 mm Null 30 mm Stroke length 50…2500 mm Dead zone 63.5 mm Ø10 mm 5 mm Cable exit option Ø37 mm Ø48 mm +5.5 mm (dead zone: 69 mm) for option: MTR. I 6I Temposonics MT Analog Redundant MTS Sensors All dimensions in mm. Mechanical Installation
Xpol | 65° Az | 16.5 dBi | 0-10° | 1910 x 253 x 147 mm Single band ...
Xpol | 65° Az | 16.5 dBi | 0-10° | 1910 x 253 x 147 mm Packaging Carton Box 2.13 x 0.35 x 0.24 m 0.180 m3 | 20 kg Several patents pending regarding this product. Quoted performance parameters are provided to offer typical, peak or range values only and may vary as a result of normal testing, manufacturing and operational conditions.
ORDERING OPTIONS - Amphenol Antenna Solutions
Manual Electrical Tilt (MET) --- 4.3-10 Female 5980600P Remote Electrical Tilt (RET) AISG v2.0 / 3GPP Multi-Device Control Unit (MDCU) 4.3-10 Female 5980600PG Multi-Device Dual Unit (MDDU) 4.3-10 Female 5980600PDx* *Pre-commissioned configuration; Contact Amphenol for further details.
ALDC_UM - Amphenol Antenna Solutions
Heading 1 ALDC_SW_UM ©2011 Amphenol Antenna Systems | www.amphenol-antennas.com Page 2 of 41 1. Introduction The Antenna Line Device Control (ALDC) system is a portable primary controller used for configuration and control of AISG v1.1 and/or
REVIEW OF THE APPLICATION OF DESIGN GUIDELINE VDI 2230 - PCB
for the dimension range M4 to M39 and for clamp length ratios lk/d < 10. Bolts with smaller and larger dimensions can be calculated according to the Guideline. The given characteristics of materials apply only at room temperature. At higher or lower temperatures allowance must be made for their temperature dependence.