Search Results for aquatic tanks
Fluid-Trac 3-Wire Level Sensor
Epqshiu & . %% Ufdiopmphft. NNE 4 Fpd0 HU/CP Tfw0 & i-rcom Note: The Fluid-Trac® 3-wire level sensor comes with an integral gasket that must be used when mounting. Mating connector parts and bolts are not included. A mating connector kit P/N is available. Note: Gasoline range is different due to the density of gasoline vapors.Gasoline vapors are denser as
Self-Adhering Surface Temperature Sensors
the water tank and an insulating jacket as shown. The sensors should NOT be used externally where they can be subjected to wind, rain and direct sun. Residual oil on the surface of a metallic tank, resulting from a drawing process, can cause a loss of adhesion. Oil residuals should be cleaned away before the application of the sensor.
Industrial Applications | Chiller Control
Thermometrics Self-Adhering Surface Temperature Sensors are designed for industrial HVACR applications, typically for placement on the external wall of a water tank or boiler reservoirs. They are also suitable for reservoir tanks working in conjunction with solar panel water heating systems.
Industrial Applications | Boiler Control
Thermometrics Self-Adhering Surface Temperature Sensors are designed for industrial HVACR applications, typically for placement on the external wall of a water tank or boiler reservoirs. They are also suitable for reservoir tanks working in conjunction with solar panel water heating systems.
Liquid Level Applications - Temposonics
The Level Plus® liquid level transmitters feature up to 5-in-1 measurement of level, interface, volume, HI level switch, and temperatures of a vessel from one opening. The Temposonics ® technology provides wear-free, continuous level measurement that does not require maintenance or recalibration. The absolute level is detected directly with one or more floats, which operate reliably even in ...
Sensors for Monitoring Water & Waste Water EQUIPMENT - PCB
Municipal water authorities oversee a vast range of infrastructure, including wastewater treatment plants, water treatment plants, lift stations, pump stations, storage tanks and miles of sewer/water pipelines. The efficient and uninterrupted operation of the system is essential in order for water authorities to stay in compliance with local ...
Temperature Sensors - Page 2
Thermometrics Self-Adhering Surface Temperature Sensors are designed for industrial HVACR applications, typically for placement on the external wall of a water tank or boiler reservoirs. They are also suitable for reservoir tanks working in conjunction with solar panel water heating systems.
Level Measurement Through Foam - Temposonics
Watercraft Tank Level Light Industrial Applications Toggle Sub Menu. Automotive Medical Equipment & Mobility Liquid Level Applications Toggle Sub Menu. AST Tank Gauging Level Monitoring of Liquid Gas Chemical Blending Tanks Inventory Monitoring of Spirits Level Measurement Through Foam
4.1" High Bright Color Display, Black - Gemeco
Maretron’s DSM410 is a 4.1” high-resolution sunlight viewable color display that interprets and displays NMEA 2000® instrument, navigation, and vessel monitoring data.
Water Detection Sensor - Amphenol Sensors
De-ionized Water Injection Vehicle Electrification ... Programmable for custom and irregular shape tanks; Dismiss ad Dismiss ad. This will close in 0 seconds. modal-check. Comm Aerospace - In-Cabin & Galley. In-Cabin & Galley Applications
Digital Fluid-Trac™
The Digital Fluid-Trac™ drum liquid level gauge is a cost competitive non-contact, continuous drum liquid level gauge. It is designed for use on vertical drums (≤ 32-inch depths) storing a wide variety of media such as water, wastewater, motor oil, hydraulic fluid, and diesel fuel.
TULC Combination Sensor - ssi-sensors.com
• Tank Profiling: Factory programmable strapping tables for volumetric tank profiling. Chemical Compatibility Gasoline, Diesel Fuel, Motor Oil, Water, Ethanol, Hydraulic Fluid, Engine Coolant. Copriht 19 SSI Technoloies LLC 3 oc TLC ev 1 ssi-sensorscom Concentration Sensor Specifications Level Sensor Specifications Temperature Sensor ...
TULC Sensor
Starting in January 2010, UREA tanks became standard equipment for most new diesel trucks, buses, sport utility vehicles and automobiles in the U.S. Tractors, bulldozers, and other non-road vehicles will follow to meet the new EPA standards. ... Detection of water dilution; Detection of contaminants such as diesel, gasoline, and oil; Immediate ...
M260 Traditional/CW In-hull - Airmar
The 50 kHz is excellent at deep-water detection, and its wide 19° beam yields broad coverage under the boat. ... When the transducer is placed inside the tank, it is properly oriented for optimal performance. The M260 is a popular choice for customers not wanting to drill a hole in their hull and for trailered or multi-hulled boats.
Model 086D20 | PCB Piezotronics
Model 086D20:Short-sledge Impulse Hammer w/force sensor & tips, 0 to 5k lbf, 1 mV/lbf (0.23 mV/N), 2.4-lb head
Military - Amphenol Sensors
Amphenol Sensors is a leading innovator in sensor technologies and measurement solutions. Offering the most diverse sensor portfolio of standard and customized products for the world’s most demanding regulatory and industry-driven applications, Amphenol creates value by providing critical information for real-time decisions.
Operation Manual Level Plus - Temposonics
in the tank (GOVT – GOVP). GOVP (Gross Observed Volume of the Product) The total volume of the tank occupied by the product liquid. When measuring only one liquid, it is also the total volume of liquid in the tank (GOVT). When measuring two liquids it is the total volume of liquid in the tank minus the volume of the interface liquid
Fluid-Trac 3-Wire Level Sensor - ssi-sensors.com
The liquid level sender measures the level of fuel in the tank. The liquid level sender sends the information to microprocessor which then sends the data to the fuel gauge or digital instrumentation to display the signal generated level. One common liquid level sender is a 33-240 Ohm resistive float sender. It consists of a float attached to
Level Plus - temposonics.com
in the tank (GOVT – GOVP). GOVP (Gross Observed Volume of the Product) The total volume of the tank occupied by the product liquid. When measuring only one liquid, it is also the total volume of liquid in the tank (GOVT). When measuring two liquids it is the total volume of liquid in the tank minus the volume of the interface liquid
SSI Technologies - Application Note FT-AN6
have parts that protrude intothe urea tank and may contaminate the urea. FluidTrac is mounted to the top of the urea tank with no parts in direct contact withthe urea. tech. Urea is slightly alkaline with a PH of ~ 9.0. Since its composition is 67.5% water it should not be kept in contact with aluminum, brass or mild steel. Urea