Search Results for axr-5
Amphenol
AMPHENOL CORPORATION Amphenol Industrial Phone: 888-364-9011 191 Delaware Avenue Sidney, NY 13838-1395 www.amphenol-industrial.com Amphenol® 97 Series Connectors are UL recognized and CSA recognized.
Model 352A59 ICP® Accelerometer Installation and Operating Manual - PCB
Spectral Noise(10 kHz) 5 µg/√Hz 49 (µm/sec2)/√Hz [1] Physical Size (Height x Length x Width) .22 in x 0.48 in x 0.25 in 5.6 mm x 12.2 mm x 6.4 mm Weight .03 oz .9 gm [1] Sensing Element Ceramic Ceramic Sensing Geometry Shear Shear Housing Material Titanium Titanium
Products for vibration monitoring - Wilcoxon Sensing Technologies
Warranty. Look for the Lifetime Warranty icon online and in our catalog. Lifetime Warranty products include many top and side exit vibration sensors with 2-pin MIL-C-5015 and 4-pin M12 output connectors, hazardous area sensors, radiation resistant sensors, dual output and triaxial sensors, seismic sensors, integral cable sensors and more.
ATHDSeries - Amphenol Sine
020 Amphenol Sine Systems orporation 427 Morley Drive linton Twp MI 803 SA 1 00 39 73 www.amphenol-sine.com [email protected] Every effort has been made to ensure that the information contained in this document is accurate at the time of publication.
Model 137B27 ICP® Pressure Sensor Installation and Operating Manual - PCB
5.0 CALIBRATION Do not try to calibrate the Series 137B2XX statically. The Series 137B2XX is calibrated dynamically by PCB using a hydraulic pulse technique. For best accuracy, use the calibration certificate supplied. Factory recalibration is available for a nominal charge. 6.0 MAINTENANCE
Model M119C12 High pressure ballistic pressure sensor, 100k psi ... - PCB
.200 16.5 20 .50 6.6 50 1.0 3.3 100 Passage Resonance vs. Passage Length Actual resonant frequencies measured in practice may differ slightly from the chart values. These differences are due to variations in the velocity of propagation of sound in air caused by changes in temperature and pressure of the air in the passage. ...
TEDS Sensors and technology - Introduction - PCB
Learn about TEDS Sensors and theory behind the Transducer Electronic Data Sheets. View TEDS equipped Impact Hammers, Impedance Heads, Single Axis & Triaxial Accelerometers and Microphones from PCB Piezotronics.
Model 106B ICP® Acoustic Pressure Sensor, 300 mV/psi, resolution ... - PCB
Sensitivity(± 15 %) 300 mV/psi 43.5 mV/kPa Maximum Pressure(step) 200 psi 1,379 kPa Maximum Pressure 2,000 psi 13,790 kPa [1] Resolution 0.0001 psi 0.00069 kPa [1] Resonant Frequency ≥ 60 kHz ≥ 60 kHz Rise Time ≤ 9 µ sec ≤ 9 µ sec Low Frequency Response(- 5 %) 0.5 Hz 0.5 Hz
Model 4115K-11A Rotary Transformer Torque Sensor Installation and ... - PCB
angles `.5 degrees 24350 indoplex circle, farmington hills,mi 48335 (248) 888-8260 e-mail: [email protected] dimensions in inches.5 degrees fillets and radii .015 max fillets and radii 0.38 max outline drawing 22675 5 / 8 1 of 1 model 4115k series rotary transformer pte 5/27/22 decimals xx ±.01 xxx ±.005 decimals x ± 0.3 xx ± 0.13 a a 2 2 6 7 5
Model 039037-50022 PCB L&T Rotary Torque Only Transducer, w/Auto-ID ...
Power Required … 5 VDC @ 120 mA max. Recommended Max RPM ¼-in Drive … 5000 3/8-in Drive … 2500 ½-inch Drive … 2500 ¾-in Drive … 2000 1-in Drive … 1000 1 ½-in Drive … 750 2 ½-in Drive … 500 . RS Technologies Division of PCB Load & Torque, Inc. Toll-Free in USA 888-684-2894 716-684-0001 www.pcbloadtorque.com ...
Model 426E01 Microphone Preamplifier Installation and Operating ... - PCB
8.0 Warranty and Service..... 5 1.0 Introduction Thank you for your purchase of a PCB high quality microphone. These microphones offer highly accurate and reliable acoustic measurements and are typically used in research and design applications. They are accurate enough for laboratory usage, yet rugged enough for field-testing. ...
Model 604B11 Low-cost Triaxial Industrial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model M624B01 Precision Quartz Industrial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
DWG NO - Amphenol Sine
18.5 MM 10.0-16.0 MM 12.0-18.0 MM " A MASTER KEYWAY " 35.3 " 35.3 90.5 Max RTS6BS18*23Sxx XXXX A2 -- UPDATE NOTES Jul-06-2017 Nick Tommy A3 -- UPDATE CABLE OD RANGE Aug-24-2017 Nick Tommy A4 -- UPDATE DRAWING Mar-21-2018 White Tommy. Amphenol Sine Systems 44724 Morle Drive, Clinton Tonship, M 48036 USA amphenolsinecom 092021
KEYED (3) PLACES - Amphenol Sine
4.1 current rating: 7.5 amps 4.2 operating temperature: -55°c to +125°c 4.3 dielectric withstanding voltage: less than 2 milliamps current leakage @ 1500 volts ac. 4.4 insulation resistance: 1000 megohms min @ 25°c. 4.5 moisture resistance: ip67 ( mated condition ) 4.6 mating cycle durability: 100 cycles 4.7 rohs compliant 5.
Model 119C12 High pressure ballistic pressure sensor, 120k psi, 0 ... - PCB
.200 16.5 20 .50 6.6 50 1.0 3.3 100 Passage Resonance vs. Passage Length Actual resonant frequencies measured in practice may differ slightly from the chart values. These differences are due to variations in the velocity of propagation of sound in air caused by changes in temperature and pressure of the air in the passage. ...
Model M119B11 Charge Output Pressure Sensor Installation and ... - PCB
.200 16.5 20 .50 6.6 50 1.0 3.3 100 Passage Resonance vs. Passage Length Actual resonant frequencies measured in practice may differ slightly from the chart values. These differences are due to variations in the velocity of propagation of sound in air caused by changes in temperature and pressure of the air in the passage. ...
Model HT378B02 ICP Microphone System Installation and Operating ... - PCB
8.0 Warranty and Service..... 5 1.0 Introduction Thank you for your purchase of a PCB high quality microphone. These microphones offer highly accurate and reliable acoustic measurements and are typically used in research and design applications. They are accurate enough for laboratory usage, yet rugged enough for field-testing. ...