Search Results for axr-5
ACCESSORIES - PCB
Used with: 602-Series (081B97, M081B97) 604/605-Series (081A68, M081A68) 624-Series (081A67, M081A67) 629-Series (081A56, M081A59)
1100 grounding modules | Products Amphenol Air LB
Oils 5 items; Cleaning products 5 items; De-icing fluids 5 items; Show More. Fire / Smoke compliance. ABD 0031 5 items; EN 2591-317 5 items; Show More. Reach status. Compliant 2 items; Not compliant ...
BergStak® 0.8mm Mezzanine Connector - Amphenol CS
High Temperature Life: 105°C ± 5°C for 1000 hours §Humidity: 90-95% relative humidity for 96 hours §Mixed Flowing Gas Class 2a (30 GXT ®) APPROVALS AND CERTIFICATIONS § UL E66906 § File no. LR46923: SPECIFICATIONS § Product Specification: GS-12-547 § Test Report: DGS-29-010: PACKAGING § Tape & Reel §Tubes: TARGET MARKETS ...
Model 378A08 MICROPHONE AND PREAMPLIFIER, LOW NOISE, 1/4 FREE ... - PCB
8.0 Warranty and Service..... 5 1.0 Introduction Thank you for your purchase of a PCB high quality microphone. These microphones offer highly accurate and reliable acoustic measurements and are typically used in research and design applications. They are accurate enough for laboratory usage, yet rugged enough for field-testing. ...
Highly Configurable Electronic Vibration Switch - PCB
Choice of Measurement Range: In order to provide a measurement range that corresponds to the application's requirements, the electronic switch can be factory-set to one of the following five options: 0 to 1.5 ips peak velocity, 0 to 3.0 ips peak velocity, 0 to 5 g peak acceleration, 0 to 15 mils peak to peak displacement or 0 to 50 mils peak to ...
Businesses - Amphenol
Each of our Amphenol businesses partners with its customers across different market segments and regions to connect our world through leading-edge innovation.
TRIAXIAL CHARGE OUTPUT ACCELEROMETER Revision: B OPTIONAL ... - PCB
Frequency Range(+/- 5 %) 4 kHz [1] Resonant Frequency ≥ 25 kHz Non-Linearity ≤ 1 % FS [2] Transverse Sensitivity ≤ 5 % Environmental Overload Limit(Shock) 3,000 g pk Temperature Range -67 to 900 °F Temperature Response See Graph [3] Base Strain Sensitivity .003 g/µε [3] Radiation Exposure Limit(Integrated Neutron Flux)
ASeries Contacts - Amphenol Sine
AT60-12-0222 ATP, DuraMate, PanelMate Pin Stamped & Formed 12 25A 10-12AWG 3.56 - 5.18mm Nickel AT60-12-0222-LP ATP, DuraMate, PanelMate Pin Stamped & Formed 12 25A 10-12AWG 3.56 - 5.18mm Nickel AT60-12-0244 ATP, DuraMate, PanelMate Pin Stamped & Formed 12 25A 10-12AWG 3.56 - 5.18mm Gold
Model 355A44 ICP® Accelerometer Installation and Operating Manual - PCB
Spectral Noise(10 kHz) 5 µg/√Hz 47 (µm/sec2)/√Hz [1] Electrical Isolation(Case) ≥ 108 Ohm Physical Size (Height x Length x Width) .32 in x 0.94 in x 0.46 in 8.1 x 23.8 mm x 11.7 mm Weight(without cable) .13 oz 3.6 gm [1] Sensing Element Ceramic Ceramic Sensing Geometry Shear Shear
Model M601A02 Low-cost Industrial ICP® Accelerometer Installation and ...
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 605B91 Biaxial ICP® Accelerometer Installation and ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 137B22A ICP® Pressure Sensor Installation and Operating Manual - PCB
5.0 CALIBRATION Do not try to calibrate the Series 137B2XX statically. The Series 137B2XX is calibrated dynamically by PCB using a hydraulic pulse technique. For best accuracy, use the calibration certificate supplied. Factory recalibration is available for a nominal charge. 6.0 MAINTENANCE
Amphenol
AMPHENOL CORPORATION Amphenol Industrial Phone: 888-364-9011 191 Delaware Avenue Sidney, NY 13838-1395 www.amphenol-industrial.com Amphenol®. 97 Series Connectors are UL recognized and CSA recognized.
Model 109C12 High pressure ICP® ballistic pressure sensor, 100k ... - PCB
Model 109C12 High pressure ICP® ballistic pressure sensor, 100k psi, 0.07 mV/psi, accel. comp. (ceramic coated integral diaphragm) Installation and Operating Manual
Model 378A04 MICROPHONE AND PREAMPLIFIER, LOW NOISE, 1/2 FREE ... - PCB
8.0 Warranty and Service..... 5 1.0 Introduction Thank you for your purchase of a PCB high quality microphone. These microphones offer highly accurate and reliable acoustic measurements and are typically used in research and design applications. They are accurate enough for laboratory usage, yet rugged enough for field-testing. ...
Model 354B04 Triaxial, Thru-hole mtg, Ceramic shear ICP® accel ... - PCB
Model 354B04 Triaxial, Thru-hole mtg, Ceramic shear ICP® accel, 10 mV/g, 0.4 to 10 kHz, Case isolated, TEDS Ver 1.0, 4-pin connector, incl. both 6-32 & M3 fasteners
Model 102A05 High resolution ICP® pressure sensor, 100 psi, 50 ... - PCB
The output bias voltage of the Model 112A23 is 5.0 volts, half the bias voltage of most PCB pressure sensors. This will cause the bias monitor meter on PCB power supplies to read at the low end of the green band. 5.0 POLARITY This sensor series produces a positive-going output voltage for increasing pressure input.
Model 086C02 Modally Tuned® Impulse Hammer w/force sensor and ... - PCB
5 Hammer model selection involves determining the size and mass of the hammer structure which will provide the force amplitude and frequency content required for proper excitation of the structure under test. Large, heavy structures like locomotive frames, tanks and bridges require an instrumented