Search Results for burst oc spray instructions
00611421006 - Amphenol Air LB
Accessory for EN4165 / SIM. EN4165 / SIM is a modular, multifunctional rectangular connector. It consists of shells and modules, which together create an integrated solution, supporting advanced signal and power requirements at a fraction of the space.
1900ND02S1X00C - Amphenol Air LB
The 1900 / EN3545 is a composite rectangular connector available with various contact arrangements. It includes sizes 22 to 8 crimp removable contacts for Copper and Aluminum cable, common with Mil-DTL-38999 Series connectors such as coax, twinax, triax and Quadrax.Standard and Overmoulded rear grommet and interfacial seal.Configurable keying and locking posts providing 36 options.
21-33382-61 (PIN) 21-33383-61 (SOCKET) Contact, Pin and Socket, Quadrax ...
Installation Instructions See table on reverse side for quadrax cable recommended, tool selector settings, crimping tool, positioner and insertion/removal tool information. A 1. Cut cable for assembly of quadrax contacts. Note: Contact assemblies of opposite gender should be assembled at cable
Model 113A24 **OBSOLETE** See 113B24 High frequency ICP ... - PCB
Return Policies and Instructions . Materials Authorization (RMA) Number. This RMA number should be clearly marked on the outside of all package(s) and on the packing list(s) accompanying the shipment. A detailed account of the nature of the problem(s) being experienced with the equipment
PS1-HCHO-1-MOD FormaldehydeModule Datasheet
Features •Highaccuracyandlonglife •Fastresponsespeed,fastreturntozero,plugandplay •Goodanti-toxicity •Easytouse,UARTdigitalsignaloutput ...
ZTP-115 Thermopile IR Sensor - amphenol-sensors.com
Parameter Limits Units Condition Min Typ Max Chip Size 1.8 x 1.8 mm2 Diaphragm Size 1.4 x 1.4 mm2 Active Area 0.7 x 0.7 mm2 Internal Resistance 42 60 78 kW 25°C
ZTP-115 Thermopile IR Sensor - amphenol-sensors.com
Parameter Limits Units Condition Min Typ Max Chip Size 1.8 x 1.8 mm2 Diaphragm Size 1.4 x 1.4 mm2 Active Area 0.7 x 0.7 mm2 Internal Resistance 42 60 78 kW 25°C
Data Sheet R-Series V RH5 POWERLINK - Temposonics
4 Temposonics® R-Series V RH5 POWERLINK Data Sheet TECHNICAL DRAWING Fig. 3: Temposonics® RH5 with ring magnet Controlling design dimensions are in millimeters and measurements in ( ) are in inches RH5-M/S-A/-V – RH5 with threaded fl ange M18×1.5-6g or ¾"-16 UNF-3A, example: Connection type D56 (connector output) 17
www.charlesindustries.com
%PDF-1.5 %âãÏÓ 613 0 obj > endobj xref 613 39 0000000016 00000 n 0000001487 00000 n 0000001601 00000 n 0000002737 00000 n 0000002877 00000 n 0000003377 00000 n 0000003883 00000 n 0000003920 00000 n 0000004034 00000 n 0000004146 00000 n 0000004173 00000 n 0000004751 00000 n 0000005021 00000 n 0000005489 00000 n 0000005746 00000 n 0000006230 00000 n 0000007125 00000 n 0000008207 00000 n ...
Centaur High Bandwidth 38999 PCB Connectors - Amphenol Aerospace ...
175°C, 500 hour salt spray, EMI Shielding -50 db @10GHz specification min. Durmalon: Nickel-PTFE alternative to Cadmium, 175°C, 500 hour salt spray, EMI -50dB: Black Zinc: Zinc-Nickel alternative to Cadmium, 175°C, 500 hour salt spray, EMI Shielding: Stainless Steel: Nickel: Corrosion resistant steel, 200°C, firewall capability, 500 hour ...
3657–01 4-Wire Foreign Exchange Subscriber (4W FXS) Channel Unit
Section 365–701–205 1. GENERAL 1.1 Document Purpose This document provides information on the Issue 5 version of the Charles Industries 3657–01 4-Wire Foreign Ex-
EMI Filters - Markets | Amphenol Aerospace
Termination Instructions AS9100/ISO9001 Certification Terms and Conditions Facility Approval Product Stewardship. RoHS Documents ... EMP is a short, intense burst of electromagnetic energy that can severely damage or disable electrical devices and electronic systems. EMPs can be caused naturally by lightning strikes or solar flares or can ...
Data Sheet - temposonics.com
4 Temposonics® GT2/GT3 Analog Redundant Data Sheet TECHNICAL DRAWING CONNECTOR WIRING D60 Signal + power supply M16 male connector Pin 1 2 3 6 5 4 View on sensor 1 V/mA 2 DC Ground 3 Only PC Programmer tool
SMPM Female R/A to SMPM Female R/A 24" Cable Assembly for .047 Cable ...
SMPM Female R/A to SMPM Female R/A 24" Cable Assembly for .047 Cable" 7032-6356
SIME0412SN - Amphenol Air LB
Module for EN4165 / SIM connectors. EN4165 / SIM connector is modular, multifunctional and rectangular. It consists of shells and modules, which together create an integrated solution, supporting advanced signal and power requirements at a fraction of the space.
00175520702 - Amphenol Air LB
1750 series consists of Quick junction modules for signal and low current distribution, where sealing (IP66 / IP68 and IP69K), space and weight-saving are prime requirements.
Thermometrics ZTP-115 Thermopile IR Sensor
Unit: mm Pin arrangement: 1. GND Thermistor 2. Thermopile 3. GND Thermopile 4 . Thermistor Outline of Sensor Packaging and Pin Arrangement (unit: mm)
00111510202 - Amphenol Air LB
Module 1100 21 contacts #22 Marking AALBF
32420021025BMT - Amphenol Air LB
32420021025BMT - Amphenol Air LB ... Pillar bolt
Temposonics LLC
Temposonics LLC 3001 Sheldon Drive Cary, NC 27513 Phone 919-677-0100, Fax 919-677-0200\ TEMPOSONICS, LLC GENERAL TERMS & CONDITIONS OF PURCHASE