Search Results for can to digital
Mastering Bandpass Filters: A Guide for RF & Electrical Engineers
Understanding what each type offers and how they suit different project needs can help you better evaluate the pros and cons of analog versus digital bandpass filters.
Pros and Cons of an Analog Bandpass Filter vs. Digital Filter - Q Microwave
Discover the critical differences between digital and analog bandpass filters, so that you can choose the right filter for your needs.
Media Converters | Products - Amphenol Aerospace
Offered in many configurations for any rugged application, our high-speed, ruggedized media converters are built for every technological gap: enabling protocol conversions, copper-to-fiber, data concentration, and more.
CRATE | Products - Amphenol Aerospace
Independent digital step attenuators for each receive channel; Run-time configuration of sampling rates, decimation, interpolation, center frequencies, Nyquist band selectivity, etc. Real-time calibration of ADC/DACs for improved spectral performance
Rugged Media Converters & Ethernet Switches - Amphenol Aerospace
Our ruggedized media converters work across a variety of protocols and include copper-to-fiber conversion, Ethernet, data concentrators, and Video (DVI, SDI, HDMI, others). Our rugged Ethernet switches series continues to expand with higher speeds and number of channels.
Noland RS11 Analog to NMEA 2000 Converter - Gemeco
The RS11 Engine Data Converter converts tachometer signals and analog gauge voltages from virtually any engine into CANbus digital messages (NMEA 2000®). It is configurable for either single or dual engine installations and includes a USB PC interface for initial configuration, data monitoring, and software updates.
SmartBoat/SmartFlex - Airmar
A simple and cost-effective way to connect and manage a variety of analog and digital sensors and devices to the NMEA 2000® network – regardless of their protocols. Unique. Powerful.
Amphenol ICC Develops 112Gb/s Interconnect Technology with eTopus ...
At the EVB RX, analog to digital converters (ADCs) digitize the incoming bit stream, fully adaptive digital signal processing (DSP) equalizes the signal levels, and finally the clock and data recovery (CDR) realizes the data stream.
Digitalizing Traditional Sensor Technologies with IO-Link - PCB
Learn how IO-Link has changed the smart sensor industry, enabling you to adapt your current sensors to offer secure digital output, customize your system, and make smarter, data-driven decisions—all while reducing the costs of streamlining data. Why IO-Link?
Smarter Vehicles - CAN Bus to Automotive Ethernet - Amphenol CS
Automotive Ethernet delivers unmatched data transfer speeds up to 100x faster than CAN bus, and will establish the necessary standards for advancing autonomous vehicle technology. Connectors like NETBridge from Amphenol ICC are ideal for automotive Ethernet connections.
New J1939 Connect Can Sensor - CMR Group
Designed for unforgiving operating environments, the robust thermocouple sensor features embedded industry compliant J1939 technology which enables real-time diagnostics and a digitized connection to an engine ECU or any other monitoring system operating under a controller area network (CAN) bus.
NEW DESIGNS FOR J1939 CONNECT CAN - cmr-group.com
Using J-SENSE technology, analog to digital conversion electronics are embedded within the sensor design, allowing a direct CAN connection to the engine ECU. The temperature is measured with a K thermocouple and the mV signal is digitally converted to CAN bus.
What’s the Difference Between 50 Ohm and 75 Ohm Coaxial Cable?
This is why every cable TV company uses 75 Ohm coax for distributing its digital video channels as well as its broadband internet data signals. Direct broadcast satellite dishes and over-the-air HDTV antennas also require 75 Ohm Coaxial Cable to ensure that all of the digital channels transfer down the cable with the lowest loss and distortion ...
Digital Temperature Sensors vs. NTC Thermistors
From Thermometrics, Inc., learn more about the features, benefits and common applications of Digital Temperature Sensors versus NTC Thermistors. NTC Thermistors – NTC stands for Negative Temperature Coefficient, meaning they reduce in impedance as temperature increases resulting in an analog voltage which varies with temperature.
SSI Technologies - Application Note FT-AN2 Fluid-Trac® 3-Wire Level ...
The Fluid-Trac® 3-wire ultrasonic level sensor is a non-contact liquid level sensor that offers a wide variety of input and output options which enables it to interface with many different microprocessor-controlled fuel gauges or digital instrumentation.
Fluid-Trac 2-Wire Level Sensor - Amphenol Sensors
Fluid-Trac® 2-wire level sensor has a factory programmed digital filter to reduce error caused by sloshing fluids. Motion of the liquid media can impact the performance of a level sensor.
Future of High-Performance Computing and Interconnect Technologies ...
By adopting these latest interconnect trends, organizations can enhance their storage infrastructures to drive innovation and discovery in an increasingly data-driven world. Interested to know how specific technologies are impacting the future of HPC and its development?
CAST - Airmar
The CAST app displays real time, speed-through-water, depth and water temperature data in a digital or graphic format. Simple offsets can be applied to compensate for the depth below keel or depth from surface.
Fundamentals of Signal Integrity - Amphenol CS
SI is about digitally transmitting a signal and then faithfully reproducing its copy at the receiving end by controlling the physical phenomena known to affect its quality. Some of the phenomena that are so prevalent in any electronic design are related to the signal itself - its reflections, resonance, and the resulting Cross Talk.
How to Use a Protimeter Moisture Meter | User's Guide
All Protimeter moisture meters will display the readings through a digital LCD display and a simple color-coded LED display. The digital LCD display will provide the moisture reading (%WME or %REL). When undertaking readings, write down this measurement for future records.