Search Results for cl-60
L-1293-B - Amphenol Aerospace
40-60 Delaware Ave. Sidney, NY 13838-1395 Website: www.amphenol-aerospace.com. Title: L-1293-B.fm Author: jogden Created Date: 4/29/2003 9:07:27 AM ...
Amphenol
AMPHENOL CORPORATION Amphenol Industrial Phone: 888-364-9011 191 Delaware Avenue Sidney, NY 13838-1395 www.amphenol-industrial.com Amphenol®. 97 Series Connectors are UL recognized and CSA recognized.
ValProbe® RT Humidity/Temperature Logger
ValProbe® RT Humidity/Temperature Logger
Aquant - protimeter.com
100% 80% 60% kk tasten for at afslutte kalibreringen. Protimeter Aquant Page 13 40% 20% Protimeter Aquant Holde/fryse avlesningen: Under måling, hvis avlesningen må fryses en observasjon, trykk under måling. Teksten "HOLD" vil vises på skjermen. Page 14 5 Utskifting av batteri ...
Board-to-Board Connectors | BTB Connector | PCB Connector | Fine Pitch ...
Amphenol's Basics offer board-to-board connectors in various categories including backplane, mezzanine, signal, power, card edge, and floating. These connectors feature design flexibility, reliability, and high performance.
FIBERQUAD - Amphenol Aerospace
o 60 minutes per axis, in each of three mutually perpendicular axes. • 40 G Peak Shock Cycle o Three hits in each axis, both directions, ½ sine and terminal-peak saw tooth, Total 36 hits. FLUIDS SUSEPTABILITY: • MIL-DTL-38999 receptacle interface per EIA -364-10E . ALTITUDE: • -1,500 to 60,000 ft Altitude Testing w/ Rapid Depressurization
2M801 Dual-Start Acme Thread Connectors - Amphenol Aerospace
2M801 is generally considered a legacy series. Its successor, the 2M805 series, has a number of important improvements, including a triple-start thread (which reduces the number of turns it takes to fully mate the connectors) and an EMI band (which increases shell-to-shell conductivity and greatly improves signal shielding).
CONEC connectors by CONEC
CONEC connectors: Technology in connectors - Designed to perform. Branches and Applications in which CONEC connectors are used:
Cross Reference - Airmar
AIRMAR provides information in this cross-reference as a guideline for choosing the correct transducer for your specific fishfinder. Our OEM customers frequently change their models, software versions and plug configuration, which may not be reflected in this cross-reference guide.
Home - Lutze Inc.
A tradition in automation for over 60 years - With countless pioneering achievements, LÜTZE is today one of the leading firms in the industry worldwide. Mr. Friedrich Lütze founded Friedrich Lütze GmbH in Weinstadt near Stuttgart, Germany, in 1958. Since then, electronic and electrotechnical components and system solutions for automation and ...
AT Connector Evaluation Test Report - Amphenol Sine
Management No. ED-ER-11007 AT Connector Evaluation Test Report Amphenol Sine Systems. Clinton Township, MI USA 09/01/11 471-1, Deba, Ritto-City Shiga, 〒520-3041 TEL: 077-553-8502 Approved Created
D38999 Series I - LJT Filter Connectors - Amphenol Aerospace
Environmental. Temperature Range:-55°C to 125°C Physical Shock: Typical to EIA-364-27 test condition C Vibration: Typical to EIA-364-28 Fluid Immersion: Typically tested to EIA-364-10 Salt Spray: Typically based on EIA/ECA-364-26 Humidity: Typically EIA-364-31 test method IV Durability: 1500 couplings minimum (in reference to connector couplings, not contacts)
PRODUCT DATA DRAWING - SV Microwave
.49612.60.60615.39.71618.19.3425±.00508.70±0.13 set screw alignment pin outer shell inner shell mt backplate captive screws rf backplate material: outer shell, inner shell, rf backplate, & mt ferrule: aluminum per astm b211 alloy 6061-t6 or ams-qq-a-200/8 alloy 6061-t6 set screw: 18-8 stainless steel captive screws
amphenol-ns.com
We would like to show you a description here but the site won’t allow us.
Datenblatt ER CANopen - Temposonics
Linearität ≤ ±0,02 % F.S. (Minimum ±60 µm) Messwiederholgenauigkeit ≤ ±0,005 % F.S. (Minimum ±20 µm) Betriebsbedingungen Betriebstemperatur −40…+75 °C Feuchte 90 % relative Feuchte, keine Betauung Schutzart 1,2 IP67 (Stecker fachgerecht montiert) Schockprüfung 100 g (Einzelschock) IEC-Standard 60068-2-27
Accelerometers / Vibration Sensors | PCB Piezotronics
Wide Frequency Response from 0 to 60 kHz; Temperatures from -400° to 1400° F (-240° to 760° C) Consistent, repeatable results; Our calibration centers are accredited to ISO 17025, and each sensor shipped includes a calibration certificate traceable to NIST. Platinum Stock Sensors ship fast and are backed by a lifetime warranty — if you ...
P66 Multisensor/CW Transom Mount - Airmar
600 W. The P66 Multisensor combines depth, and temperature functions in one housing. And it features our 50/200 kHz, dual-frequency, ceramic element.
APXVL20B 43-C-I20 - Single Band, 2-port Antenna, 2.0m, 1710-2690 MHz ...
Temperature Range °C (°F) -40 to 60 (-40 to 140 ) Lightning protection Direct Ground Survival/Rated Wind Velocity km/h 200 (150 ) Wind Load @Rated Wind Front N 410 Wind Load @Rated Wind Side N 200 Wind Load @Rated Wind Rear N 680 ORDERING INFORMATION Order No. Configuration Mounting Hardware Mounting pipe Diameter Shipping Weight
Thermometrics NTC SP Series - amphenol-sensors.com
Still Air at 77°F (25°C) .60 mW/°C .65 mW/°C .85 mW/°C 1.00 mW/°C Still Water at 77°F (25°C) 3.00 mW/°C 3.30 mW/°C 4.00 mW/°C 5.00 mW/°C Power Rating (in air) 100% Maximum Power Rating @ 77°F (25°C) .048 Watts .052 Watts .068 Watts .080 Watts Derated to 0% @ Maximum Temperature See Class See Class See Class See Class