Search Results for humidity
Amphenol Single-modeTestKit MTCK-002 Fiber Systems
Fiber Optic Solutions www.fibersystems.com Amphenol Fiber Systems International MTCK-002 Single-modeTestKit Optical Calibration Wavelengths 850, 1300, 1310 and 1550nm Power Range -3 to -60dBm
High Speed FPC Connector - Amphenol CS
Title: High Speed FPC Connector Author: Amphenol Subject: High Speed FPC (Flexible Printed Circuit) is a connector with capability to transfer data rates up to 10Gb/s.
Product Data Sheet - Temposonics
MTS Sensors R-Series Models RP and RH Temposonics® Linear-Position Sensors - Profinet Industrial Profinet Interface Product Data Sheet, Part No.: 551451, Revision A 08/13 6 Sensor mounting Model RP profile-style sensor mounting flexible installation in any position! Temposonics Model RP profile-style sensors offer two basic mounting methods; side grooves for use with mounting feet or a bottom ...
N Nitrile per AMS 3224 Yellow 135oC S Silicone per AMS ... - Amphenol Pcd
One-Handed Installation 75P Clamp The 75P Clamp is built with ease of installation and ergonomics in mind featuring interlocking legs and a snapping pre-lock.
MH-Series MH CANbus (Document Part No. 551027)
3 Temposonics® MH-Series MH CANbus Data Sheet */ Resonance frequencies excluded **/ According to calculations under use of the FKM guideline Cycles Ø 7 mm sensor rod Ø 10 mm sensor rod Dynamic pressure: < 2 × 106 pressure cycles 300 bar 350 bar Static pressure: < 2 × 104 pressure cycles 400 bar 450 bar Proof pressure: Maximum 5 minutes testing time for cylinder pressure test 525 bar 625 bar
R SeriesAnalog Temposonics
Temposonics® Sensor model RP-Profile RH-Hydraulicrod Design Profile Temposonics® RP: S-Magnetslider,jointattop V-Magnetslider,jointatfront M-U-magnet,OD33 Rod Temposonics® RH: M-FlangeM18x1.5(Standard) V-FlangeM18x1.5(Fluorelastomerhousing-seal) D-FlangeM18x1.5withbushingonrodend R-FlangeM18x1.5withthreadM4atrodend J-FlangeM22x1.5,rodØ12.7mm,800bar S-Flange¾"-16UNF-3A
FIBER OPTIC CABLE ASSEMBLY MANUFACTURABILITY AND DESIGN GUIDE
b) Character size • Character height of 0.1 inches is the default. Maximum number of characters per line is 22 to 25. • Different character heights may be used for specific applications so that information fits into the available space on the label. • All marking shall be legible or free from smears and smudges. c) Number of lines of information
SGX-7NH3-100 Datasheet - SGX Sensortech
20°C, 50% relative humidity, 101kPa. 4) Cross Sensitivity Data is for information only. Calibration is recommended with target gas as the accuracy of calibration and measurement cannot be ensured. 5) The cross sensitivities are including but not limited to the gases stated in the table. It may respond to other gases.
P1300 Low Pressure Sensor Die | NovaSensor
The NovaSensor P1300 Low Pressure Sensor Die are highly reliable, solid state pressure sensors, offered in a miniature 2.7 mm x 3.2 mm die. When excited with 1.5 mA, the P1300 produces a millivolt output that is proportional to input pressure.
Technical Papers - kayeinstruments.com
KAYE HEADQUARTERS. Amphenol Advanced Sensors Germany GmbH Sinsheimer Strasse 6 D-75179 Pforzheim. T +49 (0) 7231-14 335 0 F +49 (0) 7231-14335 29 kaye-ccpf@amphenol-sensors.com
TC-1326-A/TC-1326-AS MEMS Thermal Conductivity Sensor Elements
Humidity . . . . . . . . . . .. . . . 0 to 95%RH non-condensing NOTES 1. Because of intrinsic low thermal mass, TC elements can be heated up in less than 100 ms. This allows periodic measurement with 10% duty cycle and 1 second periodicity leading to an average power consumption < 15 mW. 2. The polarity of the supply voltage may be
Temperature Sensors - Page 2
Thermometrics, Inc., offers one of the most comprehensive ranges of temperature measurement and sensor products in the world today. From chips to value-added assemblies, with temperature ranges from -196ºC to 1150ºC, Thermometrics products play a vital role in measurement, control and protection of industrial and consumer-based applications worldwide.
Temposonics
3 Temposonics RP Powerlink V2 Data Sheet TECHNICAL DATA 1/ The number of magnets depends on the stroke length 2/ With position magnet # 252182 3/ The IP rating is not part of the UL approval 4/ Power supply must be able to provide current of 1A for power up process Output Interface Ethernet POWERLINK Data protocol POWERLINK V2 according to IEEE 802.3
Kaye LabWatch IoT
Complete Cloud Solution. Integrating high quality sensors, latest wireless and wired technologies for communication and networking abilities into an easy-to-use browser Information Management Solution, LabWatch IoT combines precise facility monitoring with effective alarming, hassle-free reporting, and secure data Cloud archiving and performance.
Events - KAYE
I agree that my data from the contact form will be collected and processed to answer my request. You can request the deletion of your data at any time by e-mail kayedataprotection@amphenol-sensors.com.You can find detailed information on the handling of user data in our data protection declaration
ARMORIPX Family - Amphenol Sine
Sealed Enclosures Amphenol Sine Systems’ Armor IPX™ Family of Sealed Enclosures provides superior protection for printed circuit boards and electronic control modules in harsh environments and off-road applications. Available in two (2) sizes, as well as three (3) different material types: Ultem® (Amber), Thermoplastic (Black) or Polycarbonate
Temperature Sensing for Medical Devices | Amphenol Advanced Sensors
Medical applications demand the ultimate in accurate and reliable monitoring of critical temperature measurement. From the Amphenol Advanced Sensors family of brands, Thermometrics, Inc., designs and manufactures an extensive line of NTC thermistors and non-contact infrared (IR) based temperature sensors for this vital market.
HDAS Series Connectors - Amphenol Aerospace
Amphenol reduces the pitch and increases the density of contacts with the HDAS range. With its robust and simple design, high density and high performance in harsh environments, HDAS rectangular connectors are the right high-density PCB connector when installation, cost and reliability must be considered.
ACOUSTIC MEASUREMENT SENSORS & INSTRUMENTATION - PCB
5. PRESSURE RESPONSE. Pressure microphones are specifically designed to be flush-mounted to a surface at the boundary of the sound field. This . allows accurate measurement of sound pressure in ducts,
Amphenol Amphenol Taiwan Corporation Sheet 1
Amphenol ® Amphenol Taiwan Corporation. Sheet 3 of 14. PRODUCT SPECIFICATION. PS-7428. Rev. E. This document is the property of Amphenol Corporation and is delivered on the express condition that it is not to be disclosed