Model 480C02 Platinum Stock Products; 1-channel, battery-powered ... - PCB
area). Immediately after connecting readout instrument, (oscilloscope, meter, recorder, etc.) to the output jack, the 47 µF coupling capacitor will begin charging through the internal resistor and input resistance of the readout instrument. This charging will cause an apparent “drifting” of the output signal until the capacitor is fully ...
Amphenol Network Solutions > 1RU 125A DUAL-FEED GMT FUSE PANEL
The Amphenol Network Solutions 125GMT10/nrg125GMT10 and 125GMT15/nrg125GMT15 fuse panels are 125A dual-feed and provide 10/10 and 15/15 GMT fuse positions. Our 125GMT/nrg125GMT panels feature ±12/±24/±48V operating voltages to serve both legacy and “next-gen” network applications. Engineered into a standard 1RU footprint that support up to 20A GMT fuses in each position, providing ample ...
Amphenol Network Solutions > 100A DUAL-FEED GMT FUSE PANEL
Front-panel features include fuse access and LED status, with input, output, ground and alarm terminals on the rear. FEATURES. Universal voltage (± 24/-48 VDC) enables standardization on a single part number for multiple network applications ... Staggered output terminal blocks facilitate “waterfall” cable management ;
250TPA08 Fuse Panel - amphenol-ns.com
Clear, flame-retardant polycarbonate cover (94V-0) protects input and output power connections and wiring from damage; Either vertical feed inputs and staggered output terminal blocks facilitate waterfall cable management, horizontal feed inputs and output connectors that speed-up installation and allow cables to exit straight back from the ...
Connectors and Cages - High Speed Input Output - Amphenol CS
High Speed Input Output - Our Businesses ; Connectors and Cages; Connectors and Cages. Filter. Filter. Apply Filters Reset All. View as List Grid. 16 Items . Show. per page. Sort By. Set Descending Direction. ExtremePort™ OSFP 112G Connectors ...
OCTIS™ - RJ45 Connectors and Cable Assemblies | FCI Basics | Input ...
FCI Basics OCTIS™ I/O connectors and cable assemblies using the RJ45 standard interface promote Ethernet-friendly signal transmission in outdoor and harsh environments like Remote Radio Units and small/macro cells.
Fluid-Trac™ - ssi-sensors.com
The Fluid-Trac™ 3-Wire ultrasonic level sensor is a non-contact liquid level sensor that offers a wide variety of input and output options which enables it to interface with many different microprocessor-controlled fuel gauges or digital instrumentation. Focus Tube Application. The Fluid-Trac™ Focus Tube Adaptor (FTA) is designed to be ...
125GMT Family - 125A Dual-Feed GMT Fuse Panel
Output fuse 20A GMT Fuse Output load 14A continuous GMT fuse Minimum short circuit interrupt rating 5000A Optional: Terminal blocks, single-hole compression lugs 20 or 30, #6-32 screws [max. lug width of .31" (7.9)]. Torque screw to 8 in/lb. (.9 N•m), max. Optional: Output wire size, single-hole compression lug #22 AWG to #6 AWG
Piezoresistive accelerometer - PCB
input Ω 6500 ±2000 6500 ±2500 6500 ±2500 output Ω 6500 ±2000 6500 ±2500 6500 ±2500 Isolation resistance 100 MΩ min at 50 VDC between leads (shorted together) and cable ... Data for sensitivity, ZMO, input and output resistance are supplied on the calibration certificate. Unless specified by the customer at time of order,
Dual-Feed 10/10-Position GMT Fuse Panel - Amphenol Broadband Solutions
Input terminals Dual stud, 1/4" on 5/8" centers Output terminals Screw terminal, #6 Chassis Ground Dual stud, #10 on 5/8" centers Alarms Alarm indicators Power, fuse alarms Alarm Type Form C Alarm connector 0.045" square pin Relay contact ratings 0.6A at 48VDC; 1A at 120 VAC Compliance Agency compliance UL, cUL, NEBS 3, CE
Dual-Feed 10/10-Position GMT Fuse Panel - Amphenol Broadband Solutions
Input rating 50A per bus Max. input interrupt device 60A Max. output protection device 15A Power dissipation (full load) 10W per bus Mechanical Dimensions 17" W x 1.75" H x 12" D (432 mm x 45 mm x 305 mm) Weight 7 lbs. (3.18 kg) Color Black Finish Powder coat Mounting 19" or 23" Environmental Temperature range -5° to 55° C
Low Noise Amplifier / Preamplifier for the 1575 MHz GPS band LNAGPline amp
Also exists with a DC block on the input. Also available with DC-path from output to input to DC-feed an active GPS antenna or to DC feed more amplifiers in series on the same line. SPECIFICATIONS Electrical Model LNA-GPS line amp-... Frequency 1575 ±10 MHz Amp. Gain 24 dB ± 1 dB @ 1575 MHz Noise Figure < 3.0 dB, Typ 2.5 dB Output IP3 >+14 dBm
Input Output | Cable Assembly | D-sub connectors | Amphenol
Amphenol's Input Output Cables are designed for high-speed data transmission in various applications, including industrial automation, telecommunications, and networking. JavaScript seems to be disabled in your browser.
109322-07 | Amphenol Global Search | Amphenol
Search Results for 109322-07 Fluid-Trac 3-Wire Level Sensor ltage Output)Product OverviewThe Fluid-Trac® 3-wire ultrasonic level sensor is a non-contact liquid level sensor that ofers a wide variety of input and output options which enables it to interface with many diferent microprocessor-controlled fuel gau. es or digital instrumentation.The ...
Amphenol Network Solutions > 300CB08 1RU Circuit Breaker Panel ...
Clear, flame-retardant polycarbonate cover (94V-0) protects input and output power connections and wiring from damage; Either vertical feed inputs and staggered output terminal blocks to facilitate waterfall cable management, horizontal feed inputs and output connectors that speed-up installation and allow cables to exit straight back from the ...
Amphenol Network Solutions > 1RU 250A DUAL-FEED, 8/8 TPA FUSE PANEL
Clear, flame-retardant polycarbonate cover (94V-0) protects input and output power connections and wiring from damage; Either vertical feed inputs and staggered output terminal blocks to facilitate waterfall cable management, horizontal feed inputs and output connectors that speed-up installation and allow cables to exit straight back from the ...
MediaGauge™ Digital Gauge - ssi-sensors.com
The MediaGauge™ models differ in accuracy, media isolation, user functions, and output capabilities. A MediaGauge™ digital pressure gauge is ideal for use in many applications such as Refrigeration, Process Control, Fuel Cells, Pumps, Hydraulics, Pneumatics, Compressors, and Agriculture. Exclusively distributed by Kodiak Controls.
Amphenol Network Solutions > 1RU 240A DUAL-FEED, 9/9 TPA/GMT FUSE PANEL
Clear, flame-retardant polycarbonate cover (94V-0) protects input and output power connections and wiring from damage; Either vertical feed inputs and staggered output terminal blocks to facilitate waterfall cable management, horizontal feed inputs and output connectors that speed-up installation and allow cables to exit straight back from the ...
Model 480B21 | PCB Piezotronics
3-channel, battery-powered, ICP® sensor signal cond., gain x1, x10, x100, BNC input/output conn. 3-channel, Battery-powered, ICP® Sensor Signal Conditioner with Gain x1, x10 and x100 for each channel. BNC input and output connectors. Uses three 9-volt alkaline batteries (included). Channels: 3
Power :: 8/8 Position Circuit Breaker Panel
• Either vertical feed inputs and staggered output terminal blocks to facilitate waterfall cable management, horizontal feed inputs and output connectors that speed-up installation and allow cables to exit straight back from the panel, or vertical feed inputs and output connectors that allow input