Search Results for input and output
Electromagnetic/piezoelectric shaker system - Wilcoxon Sensing Technologies
Notes: 1 Blocked force output refers to the force output against a mass of infinite mechanical impedance. 2 Refers to connector at shaker end of cable. 3 Refers to condition at the end of the 6 ft. low noise cable (180 pF). Accessories supplied: All input and output cables; mounting stud; spanner wrench F4 electromagnetic shaker:
1RU 240A DUAL-FEED, 9/9 TPA/GMT FUSE PANEL
Clear, flame-retardant polycarbonate cover (94V-0) protects input and output power connections and wiring from damage; Either vertical feed inputs and staggered output terminal blocks to facilitate waterfall cable management, horizontal feed inputs and output connectors that speed-up installation and allow cables to exit straight back from the ...
Micro SD and SD Card Sockets | Input Output Connectors | Amphenol
Amphenol's 2.70mm ultra-thin Micro SD and SD card sockets saves on space and has a shielded design for superior signal integrity (SI) performance.
D-Sub Cable Connectors | FCI Basics | Input Output Connectors ...
Amphenol D-Subminiature (D-Sub) connectors are part of an industry standard for applications requiring robust and reliable connectors. These proven D-Sub connectors are one of the most popular Input/Output interconnects, addressing a wide variety of appli
Input Output | Connectors - Amphenol
Input Output; Input Output. Filter. Filter. Apply Filters Reset All. View as List Grid. Results 1-24 of 110. Page. You're currently reading page 1; Page 2; Page 3; Page 4; Page 5; Page Next; Show. per page. Sort By. Set Descending Direction. Dsub Custom Specials ...
WTB BMI Fan Connectors | Input Output | Amphenol
Amphenol wire-to-board fan connectors come with Blind-Mate Interface. The 1.25mm pitch wire-to-board connectors meet a maximum of 2.8A/pin current carrying capacity
SSI Technologies - Application Note FT-AN2 Fluid-Trac® 3-Wire Level ...
variety of input and output options whh enabic les it to interface with many different microprocessor-controlled fuel gauges or digital instrumentation. The Fluid-Trac ® 3-wire level sensor can be factory programmed tohave a ratio-metric output to drive 12V fuel electronic gauges (automotive applications).
19 Rack-Mountable High-Performance HF Receiver Multicoupler series with ...
Input VSWR < 2.5:1 typ. < 1.5:1 Output VSWR Max. 1.5:1 typ. < 1.3:1 Isolation between outputs > 20 dB Input-Output Isolation > 35 dB Power Supply 198 to 264 V AC, max. 160 mA DC Supply 10.8 to 14.4 V DC, max. 2A No. of channels 4, 8, 12 or 16 Mechanical Power Connector 3-terminal IEC60320-1 C14 (male)
Engineering Assets - All Sensors
For amplified output sensors the range can be extended only ten percent before the output is "railed" to the output voltage limit. Output Span: Is the output voltage for the specified operating pressure range. For sensors without internal voltage reference the span is ratiometric to the supply voltage of the sensor.
Telaire T67XX CO2 Sensor Module - Amphenol
1 UART TX (output from sensor) 2 UART Rx (input to sensor) 5 Becomes a test input for Telaire and should be left unconnected by the user 6 Becomes an output pin used to control an RS485 transceiver Figure 4 - Simplified Schematic I/O Configuration #3 The condition described by (3) above is useful if the sensor is used in an RS485 dropped node ...
M362 Series - amphenol-aerospace.com
Input Current Limit Input Current is actively limited by the UPS to 30Arms (including during Overload). AC Output Output Configura-tion Two Outputs (AC1 and AC2) sharing a common Neutral. AC-2 is intended for non-essential loads and in case of a pro-long failure of the AC Input, the user may save battery power
OCP ORv3 AC Input Connector and Cable Assemblies
Amphenol OCP-compliant AC Input Connectors and Cable Assemblies are designed to meet OCPs V3 Universal Input power distribution architecture standards and provide a convenient method of routing power directly from the busway to the power shelf within the
Latch N Lok Crimp | FCI Basics | Cable to Board | Input/output connector
FCI Basics Latch-N-Lok is a shielded, latching input/output connector system with PCB receptacles and cable plug kits for signal, power, grounding and shielding applications. JavaScript seems to be disabled in your browser.
Model 691C42/691013 Switch box with switched & continuous outputs ... - PCB
Model 691C42/691013 Switch box with switched & continuous outputs, 10" x 8" x 6" NEMA 4X (IP66) fiberglass enc, 12 ch, terminal strip input, vib & temp jack and two-pin MIL connector outputs, one 1.5” conduit
240GT54/nrg240GT54 240A Dual-Feed Combination Fuse Panel
• Clear, flame-retardant polycarbonate cover (94V-0) protects input and output power connections and wiring from damage • Either vertical feed inputs and staggered output terminal blocks to facilitate waterfall cable management, horizontal feed inputs and output connectors that speed-up installation and allow cables
ACU-I20-B1 - Amphenol Antenna Solutions
According to AISG: Male is input, Female is output (Male/Female can be input and output) Hardware Interface --- RS485 A/B (5 Pin, 3 Pin), Power Supply (1 Pin, 6 Pin), DC Loop (7 Pin) Adjustment Time (Full Range) Sec 10 ~ 120 (Typical 40S, Depends different Antenna) Lightning Protection Rating --- 8/20µS Differential-Mode 5KA Common Mode 8KA
A Guide to Audio Connectors - Amphenol NEXUS Technologies
These connectors will be either male or female in design, with input or output capabilities. They are available with a variety of options for better application flexibility, including adaptors for handling compatibility issues or locking devices such as screw bolting or blade locking to prevent broken or improper connections. Learn more about ...
VPX DC/DC POWER SUPPLY - Amphenol Socapex
200V between Input and Output 200V between Input and Case 100V between Output and Case 2) Efficiency Up to 91.5 % (see Para.4) Line/Load regulation EMC Qualified to: -STD 461G1 CE101, CE102, CS101, CS114, CS115, CS116 Ripple and Noise Typically, less than 50mV p-p (max. 1% p). Measured across a 0.1μF capacitor and 10μF capacitor on
Electromagnetic shaker system - Wilcoxon Sensing Technologies
Bias output voltage, nominal 8 VDC Output impedance <100 Ω Electrical noise, equiv. g: Spectral 10 Hz 100 Hz 1,000 Hz 15 µg/√Hz 5 µg/√Hz 1 µg/√Hz Connector2 BNC Output cable R1-2-J93-10-L1 Force gage nominal values Voltage sensitivity 100 mV/lb (22.5 mV/N) Power requirements: voltage source current regulating diode 18 - 30 VDC 2 - 10 mA
Model 682A02 DIN rail mount ICP® signal conditioner, 24 VDC input ...
Electrical Connector(ICP® Sensor Input) Screw Terminals Screw Terminals Electrical Connector(Output) Screw Terminals Screw Terminals Electrical Connector(DC Power Input) Screw Terminals Screw Terminals Mounting DIN Rail DIN Rail Size (Height x Width x Depth) 3.1 in x 0.97 in x 3.3 in 78.7 mm x 24.6 mm x 83.8 mm Weight 0.194 lb 0.088 kg