3082-619X-dB - XMA
Adapters. Maintaining input power with high signal integrity; Power Dividers. Splitting power input to identical outputs; ... CURRENT STOCK Out of Stock. View Distributor Website. East Coast Microwave Sales and Distribution, LLC 800-786-2576 sales@ecmstockroom.com www.ecmstockroom.com.
Telaire T6723-8K5 NDIR CO2 Module - amphenol-sensors.com
Power Input • 4.3VDC – 7.0VDC Average Current @ 6.0 VDC with 100k pull up resistors • 2 minute sampling rate < 2.0mA per hour average, typical • 15 second sample rate < 8.0mA per hour average, typical Peak Current • < 100mA ± 10% Low Voltage Shut-down • 4.3 VDC ± 5% Connector (5-pin) • Pin 1 → Ventilate Warning • Pin 2 → ...
PERFORMANCE SPECIFICATION SENSOR 6, DEGREES OF FREEDOM 7360A -XXX YYY ZZZ
4.1.6 INPUT VOLTAGE PROTECTION REVERSE POLARITY PROTECTED . 4.1.8 INSULATION RESISTANCE 100 Meg Ohms minimum at 50 Vdc . ... 4.2.2 CURRENT DRAIN 6 mA max each rate sensor axis, 18mA max total. 4.2.3 OUTPUT IMPEDANCE 200 ohms max . 4.2.4 MAXIMUM EXCITATION 20 Vdc . VOLTAGE WITHOUT DAMAGE . 4.2.5 COMMON MODE VOLTAGE (±5%) 2.5 Vdc .
Temposonics
Input voltage - Polarity protection - Overvoltage protection Current drain Ripple Electric strength 5 pin DeviceNet connector M12x1 24 VDC (-15 / +20 %); UL Recognition requires an approved power supply with energy limitation (UL 61010-1), or Class 2 rating according to the National Electrical Code (USA) / Canadian Electrical Code. up to -30 VDC
Pwrblade ULTRA Connector System | Power Solutions | Amphenol
PwrBlade® ULTRA's design offers an overall height reduction of 24% to reduce airflow impedance in high-density power supplies. Three contact choices are available; High Power, Low Power, and Signal.
power blade | Amphenol Global Search | Amphenol
High current carrying capacity with miniaturized shape. Up to 25A per power blade. 2 to 10 power blades on 2.0mm pitch. 20 to 120 signal pins on 0.5mm pitch. ... Amphenol Global Search | Amphenol power: 2 watt (power input derated linearly from 25c to 0.5 watts at 125c) peak power: 500 watts (peak power for a duty cycle of 5x10-4 maximum pulse ...
Power Distribution Units (PDU) - Amphenol Socapex
Our Power Distribution Units (PDU) provide advanced load balancing, surge protection and spike protection per MIL-STD-1275C-E or MIL-STD-704A-F, and are expertly constructed to Control and diagnostic via CAN bus and/or RS-485 and/or Ethernet. Integrate crucial systems seamlessly, maximize energy use, and provide operations a strong foundation with 28V to 600V PDU Technologies.
M7028 SERIES | Products | Amphenol Aerospace
The M7028 military power supply is a rugged DC to DC converter which accepts an 18 - 48VDC input voltage range and provides a single DC output from 3.3 to 50V at up to 200W. Custom outputs available upon request and the unit is Designed to meet military standards, MIL-STD-704, MIL-STD-1275, MIL-STD-810, MIL-STD-461.
vietnam | Amphenol Global Search | Amphenol
Types of Power Cables at Amphenol OCP ORv3 AC Input Connector and Cable Assemblies. Created in accordance with the OCP's (Open Compute Project) V3 Universal Input power distribution architecture standards, Amphenol’s AC input cable assemblies are a convenient solution to channel power from the grid to the power shelf inside of a V3 rack.
3082-6502-dB - XMA
Adapters. Maintaining input power with high signal integrity; Power Dividers. Splitting power input to identical outputs; ... CURRENT STOCK Out of Stock. View Distributor Website. East Coast Microwave Sales and Distribution, LLC 800-786-2576 sales@ecmstockroom.com www.ecmstockroom.com.
8502-7100-02 - XMA
Adapters. Maintaining input power with high signal integrity; Power Dividers. Splitting power input to identical outputs; ... CURRENT STOCK Out of Stock. View Distributor Website. East Coast Microwave Sales and Distribution, LLC 800-786-2576 sales@ecmstockroom.com www.ecmstockroom.com.
Model 672A01 | PCB Piezotronics
Current Consumption: 150 mA: 150 mA: Sensor Power Supplied: 24 VDC @ 2.2 mA: 24 VDC @ 2.2 mA: Physical: Size - Height: 8.00 in: 203 mm: ... Buffered Sensor Analog Output: BNC : BNC : Sensor Select timeout: 15 min: 15 min: Channels per Board: 8 : 8 : Input Connector: Terminal Strip: Terminal Strip * All specifications are at room temperature ...
Temposonics II
Input Voltage: ± 12 to ± 15 Vdc Current Draw: Transducer Only: ± 15 Vdc at 100 mA maximum, 25 mA minimum (current draw varies with magnet position, maximum draw occurs when magnet is at 2 in. (50.6 mm) from the flange and minimum update time is being utilized) Transducer with: • RS-422 Personality Module (RPM): ± 12 to ±15 Vdc at 140 mA ...
Model 426A07 | PCB Piezotronics
Constant Current Excitation: 2 to 20 mA: 2 to 20 mA: Impedance (Input) 20000000000 Ohm: 20000000000 Ohm [1] Capacitance (Input) 0.15 pF: 0.15 pF [1] Output Bias Voltage: 10 to 14 VDC: 10 to 14 VDC: Impedance (Output) 50 Ohm: 50 Ohm: Output Voltage: ±8 V: ±8 V [1] Physical: Housing Material: Stainless Steel: Stainless Steel
Omni Antennas 422x.09-405-Txx - AMPHENOL PROCOM
Input Power: 300 W: Omni Deviation: ± 1 dB: Polarisation: Vertical: ... (3rd Order, 2 x Tx @ 43 dBm) (PIM value not guaranteed for N connector version) Lightning Protection: Lightning current handling capability : 200 kA According to EN 62305-1 (Test pulse 10/350 μs) Antistatic Protection: All metal parts DC-grounded (Connector shows a DC ...
482C54 4-CHANNEL ICP® SENSOR SIGNAL CONDITIONER - PCB
Constant Current Excitation(To Sensor) 0 to 20 mA 0 to 20 mA [1] Output Impedance ≤ 50 Ohm ≤ 50 Ohm Overload Threshold(± 0.2 Vpk) +10 Vpk +10 Vpk ... Calibration Input(± 1 %) ± 1000 pC/V ± 1000 pC/V Physical Electrical Connector(ICP® Sensor Input) BNC Jack BNC Jack
Model 603C01/ICS-14 Industrial ICP® Accelerometer Installation ... - PCB
current circuit), and a capacitor for decoupling (removing the bias voltage) the signal. The current-regulating device is used in place of a resistor for several reasons. The very high dynamic resistance of the diode yields a source follower gain which is extremely close to unity and independent of input voltage.
Data Sheet E-Series ER Analog - Temposonics
I 2 I Temposonics® E-Series ER Analog Data Sheet 4 5 3 1 Measurement Cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter 5 Time-of-fl ight converted into position Sensing element (Waveguide) Position magnet (Magnetic fi eld)
Accelerometer simulator - PCB
Input/Output Characteristics Outputs Frequency Range Signal Ouputs Tachometer Output Amplitude Single-ended Charge (pC) Differential Charge (pC) Single ended Voltage (mV) Tachometer (TTL) IEPE - current sinking, 2-20mA, at a compliance voltage of 24VDC 1Hz to 20kHz, resolution 0.5Hz 1 Hz to 25kHz Up to 10,000 pC or mV pk Acceleration and ...
8502-7102-02 - XMA
Adapters. Maintaining input power with high signal integrity; Power Dividers. Splitting power input to identical outputs; ... CURRENT STOCK Out of Stock. View Distributor Website. East Coast Microwave Sales and Distribution, LLC 800-786-2576 sales@ecmstockroom.com www.ecmstockroom.com.