Search Results for input current
Model 137A22 ICP® Pressure Sensor Installation and Operating Manual - PCB
137A20 with a 2 to 20 mA constant current at +20 to +30 VDC through a current-regulating circuit. If using a battery-operated unit, the constant current is 2 mA. See Guide G-0001B for powering and signal utilization information pertinent to all ICP® instrumentation. Switch power on and observe reading of bias
Modular Jack With Integrated Magnetics - RJMG Series - 2xN - Amphenol CS
Current § Solderability: Per EIA-364-52, 95% Coverage after Category 2 Steam Aging TARGET MARKETS/APPLICATIONS Communications Consumer Data Industrial & Instrumentation ... RJMG, Input output Connectors, 2x1 10G RJMG3211L11D3FR RJMG, Input output Connectors, 2x2 10G RJMG322DN11E3ER RJMG, Input output Connectors, 2X6 10G RJMG3266N11G0ER
Model RH401B04 - PCB
frequency response of systems with long input cables. (The Model 401B04 simulates the circuit of an ICP ® sensor while the signal generator takes the place of the sensor’s crystals.) 2. INSTALLATION AND OPERATION CAUTION: Connect the output only to an ICP ® type, current-limited signal conditioner. WARNING: Excessive current may damage this ...
USB 2.0 Connector | FCI Basics | Input Output Connectors | Amphenol
Current rating of 2.1A to 2.9A; Caters to power application requirements; Halogen-free products; Aid efforts to minimize the use of environmentally sensitive materials in the electronics industry; Lead-Free and RoHS compliant; Meets environmental, health and safety requirements
Amphenol Connectors | Cable Assemblies | Interconnects | Mobile, RF, Optics
Amphenol Communications Solutions (ACS), a division of Amphenol Corporation, is a world leader in interconnect solutions for Communications, Mobile, RF, Optics, and Commercial electronics markets.
New UHT-12™ Miniature Accelerometer | PCB Piezotronics
Built-in ICP® microelectronics provide a low noise, low impedance output signal capable of being transmitted over cable lengths of hundreds of feet. Any ICP® signal conditioner or data acquisition system that incorporates an ICP® constant current excitation can be used to power the accelerometers. Both models are available for immediate ...
PCU-4-XX Spec Sheet - Amphenol Antenna Solutions
Input Data Connector USB series B receptacle External Power Supply - Input 90-246 VAC, 47-63 Hz External Power Supply - Output 24 VDC, 1.75 A ... manufacturers’ equipment due to differing RET current consumption and control cable resistance. SYSTEM CONFIGURATION PCU-4-xx Portable Control Unit NODE B
Minitek® Pwr 3.0 | Wire to Board Connectors - Amphenol CS
Minitek® Pwr 3.0 is a flexible and comprehensive solution designed for power application with current rating up to 8.5A per circuit. It is available in 2 to 24 circuits for dual row and 2 to 12 circuits for single row. ... Input Output. D-Subminiature. DisplayPort. HDMI. High Speed I/O. Industrial Ethernet. Lighting. Modular & Magnetic Jack ...
10169063 | Amphenol Global Search | Amphenol
Our solutions include Signal & Mid Power Wire-to-Board, Board-to-Board, Input/Output, FFC/FPC and Backplane. We offer interconnection systems from 2.54mm pitch down to 0.40mm pitch, supporting speeds up to 25Gb/s. ... The Amphenol Socapex connector USB3CFTV is a cutting-edge solution for data transmission in harsh environments. With its thread ...
3782-600X-dB - XMA
Adapters. Maintaining input power with high signal integrity; Power Dividers. Splitting power input to identical outputs; ... CURRENT STOCK Out of Stock. View Distributor Website. East Coast Microwave Sales and Distribution, LLC 800-786-2576 sales@ecmstockroom.com www.ecmstockroom.com.
10-70500-28 | Amphenol Global Search | Amphenol
Developed in the 1980’s to provide solutions to problems caused by the high mating and unmating forces of conventional pin and socket contact pairs. 4 Body styles: mother board (MB), daughter board (DB), PC connector, input/ output connector. Search Results for 10-70500-22.
Low Noise Amplifiers PRO-QLNA 380-520 - AMPHENOL PROCOM
Low input and output VSWR ensure excellent matching to other units. Low weight. Wide temperature range. Wide supply voltage range. Low power consumption. DC supply from phantom voltage on the output cable, e.g. by means of junction box PRO-JB1-1G. UV-resistant ABS box with water drip. N-female connectors on input and output.
Model EX682A40 | PCB Piezotronics
Constant Current Excitation: 3.1 to 4.1 mA: 3.1 to 4.1 mA: Output Voltage +/-2.5 Vpk +/-2.5 Vpk: Output Bias Voltage: 10 to 12 VDC: 10 to 12 VDC: Broadband Electrical Noise (1 to 10000 Hz) ... (Input) Terminal Strip: Terminal Strip: Electrical Connector (Output) Terminal Strip: Terminal Strip: Mounting: DIN Rail: DIN Rail: Case Material ...
G-Series GP/GH Analog/Digital Outputs - Temposonics
“interrogation” current pulse applied along the waveguide. The resulting strain pulse travels at sonic speed along the waveguide and is detected at the head of the sensing element. ... Standard 24 Vdc and extended input power supply options for compatibility with older controller interfaces Integral connector replacement options including ...
2082-617X-dB - XMA
Adapters. Maintaining input power with high signal integrity; Power Dividers. Splitting power input to identical outputs; ... CURRENT STOCK Out of Stock. View Distributor Website. East Coast Microwave Sales and Distribution, LLC 800-786-2576 sales@ecmstockroom.com www.ecmstockroom.com.
HPCE Board To Board Connectors | Power Solutions | Amphenol
The HPCE BTB is a board to board high power connector for demanding applications requiring high linear current density and small connector size. It is part of Amphenol's HPCE® series family together with HPCE and HPCE cable assembly.
Level Plus - Temposonics
Input Voltage: 24 to 26 Vdc Sleep Mode Current: 1.5 mA maximum Operating Current: 15 mA maximum Back Light Current: 50 mA maximum (optional) Display: Custom Liquid Crystal Display Display Precision: ±0.01” (decimal mode) ±1/16” (fractional mode) Display Contrast: User adjustable Serial Interface: EIA-485 8 - Bit ASCII MTS Protocol ...
EV/HEV Sensor Solutions | Amphenol Advanced Sensors
Input voltage options: 5V / 12V / 48V. Combined Pressure & Temperature Sensors. Measure pressure in the cooling system, while, at the same time, measure temperature of the coolant for optimum thermal management. ... Inductive eddy-current with weight and size reduction ; Stable output over extended temperature range (-40ºC/+160ºC) and radial ...
Digitalizing Traditional Sensor Technologies with IO-Link - PCB
Learn how IO-Link has changed the smart sensor industry, enabling you to adapt your current sensors to offer secure digital output, customize your system, and make smarter, data-driven decisions—all while ... The installation process with a separate gateway is likely to involve manual input of sensor specifications like operating temperature ...
ey features For Sale Product Not Legacy - pcb.com
RCC input VEL-COIL or RCC input. Internal jumper selectable Constant current supply 8.6 mA ±10% Compliance voltage 24 V maximum, 20 V minimum. Input sensitivity limited to 15 to 150 mV/g. Velocity coil input VEL-COIL or RCC input. Internal jumper selectable Input impedance 100 kΩ. Input sensitivity limted to 15 - 1500 mV/IPS