Search Results for miv valuation
Search Results for mls neteris customer service number - amphenol.com
b) Increment the number in configuration. 3. DOWN / Decrement : a) Navigate down through menu. b) Decrement the number in configuration. 4. Ref/ Right/ Record/ Hold : a. Press to hold and release reading while in measurement. b. Press to record value while in measurement. c. Press and hold to get in to reference
Model 3501B1220KG Piezoresistive Accelerometer Installation and ... - PCB
sensors were designed with relatively high value resistors (approximately 10 times that of other devices) to maximize battery life. 4.0 Common Applications The 3500/3600 Series PR Shock Accelerometers achieve true DC response for measuring long duration shock. For this reason, they are preferred for applications in which integration ...
VQ500 Series Datasheet - SGX Sensortech
to ensure that it will withstand an impact energy in excess of 7 J low risk of impact value specified in EN 60079 -0 clause 26.4. 5. The VQ500 Series Gas Sensing Heads have not been assessed as a safety device (EHSR 1.5). 6. There are no user-serviceable parts in the component. 7.
Model 3503C202KG Surface Mount Piezoresistive Triaxial Shock ... - PCB
sensors were designed with relatively high value resistors (approximately 10 times that of other devices) to maximize battery life. 4.0 Common Applications The 3500/3600 Series PR Shock Accelerometers achieve true DC response for measuring long duration shock. For this reason, they are preferred for applications in which integration ...
Model 3501B1260KG Piezoresistive Accelerometer Installation and ... - PCB
sensors were designed with relatively high value resistors (approximately 10 times that of other devices) to maximize battery life. 4.0 Common Applications The 3500/3600 Series PR Shock Accelerometers achieve true DC response for measuring long duration shock. For this reason, they are preferred for applications in which integration ...
SGX Infrared Gas Sensor Evaluation Kit IR-EK2 User Guide
The values in the axis can then be changed. To do this, double-click on the value you wish to edit and adjust using the keypad. The ‘Readings’ tab provides measurement and control of the bulb and measurement of channel peak-to-peaks and ratios, described in section 7 and 8
M916 Series - amphenol-aerospace.com
output voltage exceeds nominal value by 10% ± 5%. Passive Overvoltage Protection A transorb is placed across the output, selected 20% ± 10% above nominal voltage. Overload / Short-circuit If the load exceeds maximum current by 20% ± 10%, the protection mechanism causes the output to hiccup (turn off
PCB Piezotronics | Measure vibration, pressure, force, and more
PCB Piezotronics | Measure vibration, pressure, force, and more
Temposonics
Measured value Position Measurement parameters Resolution 1 μm, 2 μm, 5 μm, 10 μm, 20 μm, 50 μm, 100 μm Cycle times Stroke length 300 750 1000 2000 mm Measurement rate 3.7 3.0 2.3 1.2 kHz Linearity1 < ±0.02 % F.S. (minimum ±50 µm) Repeatability 0.001 % F.S. (minimum ±2.5 µm) Operating conditions
Model 3711E1150G - PCB
%PDF-1.4 %âãÏÓ 9 0 obj >/Parent 12 0 R/Rotate 90/MediaBox[0 0 612 792]>> endobj 132 0 obj >stream xœå]ï“ ·q-‘ wdiIš")’¢VâQº•¼ÃÁ`0?BËV ÉL +ŠbV僙ONœTʧ”ø%ÿ~ ˜ úaçíÎÞ eË IUê›Á4 Ý ÆC£gö‡eY˜jYú #ñ‡Ó£ ŽªÆ.ë¦\ž ª1®\þéÈÖ5’þþŸŽþëè_—ß 5Ëÿ= ]ÛwÝòÅ‘-íÒ•þqO5ÆtÒòwGß Îå²); X—‘Ÿ«MFú ¼+ ûG*ÿ ...
Model 3743G112G Accelerometer, VC, 2g, triaxial, differential, screw ...
increase in value while the characteristics of the portion other decrease when exposed to acceleration. This approach mini-mizes common mode errors and improves non-linearity. A selection of full scale measurement ranges attained by is modifying the stiffness of the suspension system of the proof
E-Series Model EP2 Digital-Pulse (Start/Stop) Output Sensor - Temposonics
value and the sensor’s unique gradient value (inverse of the speed for the sonic pulse travel-ing in the sensor’s waveguide). (see 'Figure 1’). Communication and programmability SENSOR PaRaMETER uPLOaD FEaTuRE For applications using smart sensor interfaces, the E-Series Model EP2 with digital-pulse output comes with the ability to perform
Thermometrics NTC Diode Thermistors - amphenol-sensors.com
Thermometrics NTC Diode Thermistors - amphenol-sensors.com
Model 8120-110A POWER SUPPLY Installation and Operating Manual - PCB
Equivalent Input value is accurately known, it can be used as a reference point for shunt calibration of the system. Upon completion of installation of the transducer and its associated cabling, the user can: 1. Perform an overall deadweight calibration using a precisely known value of mechanical input. The calibration can then be transferred
Data Sheet R-Series V RH5 EtherNet/IP 551954 - Temposonics
Measured value Position, velocity/option: Simultaneous multi-position and multi-velocity measurements up to 20 magnets Measurement parameters Resolution: Position 1…500 µm (selectable) Cycle time 1 Stroke length ≤ 2000 mm ≤ 4800 mm ≤ 7620 mm Cycle time 1.0 ms 2.0 ms 3.0 ms Linearity deviation2 Stroke length ≤ 500 mm > 500 mm
www.connectpositronic.com
www.connectpositronic.com
M4268 SERIES - Amphenol Aerospace
Peak value of 5 x IIN for initial inrush currents lasting more than 50 µSec. Active over voltage protection on VS# outputs 20% ± 5% above nominal voltage. Automatic recovery when output voltage drops below threshold. Under Voltage Unit shuts down when input voltage drops below 16.5± 0.5VDC. Automatic restart when input voltage returns to ...
Industrial | Markets - Amphenol
Amphenol-CTI manufactures value-added solutions for a broad range of industries and applications. We integrate cables and harnesses into more complex solutions. Certifications: UL, CSA, ISO9001, CE, IPC 620, WHMA, C-TPAT, IATF16949 (and others) Capabilities: Customized panels and cabinets / Distribution boxes / Fiber optics / Protos to volume ...
High Power 38999 Connectors with High Current Contacts
The Amphenol Tri-Power connector series incorporates your choice of RadSok contacts, Temper-Grip High Current contacts, or standard high power contacts. Paired with the proven performance of the MIL-DTL-38999 connector series, the Tri-Power series offers a variety of tooled arrangements specifically designed to carry high current (70 to 250 amps per contact, 240 to 1000 amps per connector).
Bearing Fault Detector - pcb.com
Green Line: Captured Peak Value Orange Line: Overall RMS Value Blue Line: Analog Vibration g‘s g‘s Time Normal operation Onset of fault IMISensors Toll-Fre einUSA800-959-4464 716-684-0 003 www.imi-sensors.com 3 Model 682A05. POWER LED ANALOG OUTPUT 3.9 (99) 0.9 (22.5) 4.5 (114.5) 0.5 (12.7)