Signal Conditioning Basics | PCB Piezotronics
Fixed voltage sensitivity independent of cable length or capacitance. 2.) Low output impedance (<100 Ohms) allows signals to transmitted over long cables through harsh environments with virtually no loss in signal quality. ... For this case the negative voltage range is 8 volts. In the positive direction, the voltage swing is limited by the ...
Model 352C33 | PCB Piezotronics
Model 352C33:Platinum Stock Products; High sensitivity, ceramic shear ICP® accel., 100 mV/g, 0.5 Hz to 10k Hz, 10-32 side conn. ... Output Bias Voltage: 10 to 15 VDC: Frequency Range: 6 to 10000 Hz: Frequency Range: 4.5 to 15000 Hz: Temperature Range-65 to +325 °F-54 to +163 °C: Discharge Time Constant: 0.07 to 0.15 sec:
VIBRATION FUNDAMENTALS - PCB
measurement range. ICP ® Measurement Output. Accelerometer Sensitivity (AS): 10 mV/g Peak Measurement (G. max): ± 500 g Output (VDC) = AS . x. G. max = 10 mV/g x 500 g. Output = 5,000 mV = 5.0 VDC. Charge Measurement Range. The max acceleration measurable with . this sensor & converter combination Accelerometer Sensitivity (AS): 10 pC/g ...
Troubleshooting accelerometer installations - Wilcoxon Sensing Technologies
This DC voltage needs to be blocked by a coupling capacitor in the measurement equipment, leaving the AC output signal. Most vibration data collectors, monitors, and sensor power ... power is within the specified range. For example, if the BOV is 12 VDC and the input power is specified as 18 to 30 V, then the BOV will be 12 VDC if the input ...
VIBRATION FUNDAMENTALS - PCB
measurement range. ICP ® Measurement Output. Accelerometer Sensitivity (AS): 10 mV/g Peak Measurement (G. max): ± 500 g Output (VDC) = AS . x. G. max = 10 mV/g x 500 g. Output = 5,000 mV = 5.0 VDC. Charge Measurement Range. The max acceleration measurable with . this sensor & converter combination Accelerometer Sensitivity (AS): 10 pC/g ...
IEPE Vibration Sensors - Wilcoxon Sensing Technologies
Standard amplitude range, 100 mV/g sensitivity. 712F - Integral cable, side exit, 8-32 mounting thread; ... 786V - Wide frequency range; High voltage isolation accelerometers. Electrically isolated sensors with high EMI resistance for vibration monitoring in high electromagnetic environments, such as wind turbines and railway systems ...
Model 356A16 Platinum Stock Products; Triaxial, high sensitivity ... - PCB
Transverse Sensitivity ≤ 5 % ≤ 5 % Environmental Overload Limit(Shock) ± 7000 g pk ± 68,600 m/s² pk Temperature Range(Operating) -65 to +176 °F -54 to +80 °C Temperature Response See Graph See Graph [1] Base Strain Sensitivity 0.001 g/µε 0.01 (m/s²)/µε [1] Electrical Excitation Voltage 20 to 30 VDC 20 to 30 VDC
FORCE & STRAIN FUNDAMENTALS - PCB
gain and measurement range. In-line charge converters typically have a fixed gain and measurement range. ICP ® Measurement Output. Force Sensitivity (FS): 500 mV/lb. Measurement Range (MR): 10 lb compression. Signal Output (V. out) S x MR= F = 10 mV/g x 500 g. V. out = 5,000 mV = 5.0 volts. Output = 5,000 mV = 5.0 VDC. Charge Measurement Range
Model 378B02 | PCB Piezotronics
Polarization Voltage: 0 V: 0 V [4] Excitation Voltage: 20 to 30 VDC: 20 to 30 VDC: Constant Current Excitation: 2 to 20 mA: 2 to 20 mA: Output Bias Voltage: 10 to 14 VDC: 10 to 14 VDC: Maximum Output Voltage: ±7 Vpk: ±7 Vpk: Output Impedance: 50 Ohm: 50 Ohm: Physical: Housing Material: Stainless Alloy: Stainless Alloy: Venting: Rear: Rear [5]
HIGH AMPLITUDE MEMS SHOCK ACCELEROMETER Revision: D - PCB
Sensitivity(± 50 %)(at 10 VDC excitation) 0.010 mV/g 0.001 mV/(m/s²) [2] Sensitivity 0.001 mV/V/g 0.0001 mV/V/(m/s²) [7] Measurement Range ± 0 to 20,000 g ± 0 to 196,100 m/s² pk Frequency Range(± 1 dB) 0 to 10,000 Hz 0 to 10,000 Hz ... Settling Time is the maximum time after power-up for the Offset Voltage to be within +/-2% of
Model 086D20 | PCB Piezotronics
Model 086D20:Short-sledge Impulse Hammer w/force sensor & tips, 0 to 5k lbf, 1 mV/lbf (0.23 mV/N), 2.4-lb head
Introduction to Piezoelectric Force Sensors | PCB Piezotronics
Determining the sensitivity of sensors with operating ranges from 5 000 to 100 000 lbs (22,24 to 444,8 kN) is performed by placing the force sensor in a hydraulic press stand. In series with the sensor is a Morehouse proving ring reference force standard selected for the operating range of the sensor.
ICP® PRESSURE SENSOR - PCB
Measurement Range 8.0 psi 55.1 kPa Sensitivity(± 15 %) 300 mV/psi 43.5 mV/kPa Maximum Pressure(step) 200 psi 1,379 kPa Maximum Pressure 2,000 psi 13,790 kPa [1] ... Output Bias Voltage 3 to 8 VDC 3 to 8 VDC Physical Sensing Geometry Compression Compression
TRIAXIAL ICP® ACCELEROMETER - pcb.com
Model Number 356A43 TRIAXIAL ICP® ACCELEROMETER Revision: G ECN #: 55022 Performance ENGLISH SI Sensitivity(± 10 %) 10 mV/g 1.02 mV/(m/s²) Measurement Range ± 500 g pk ± 4,905 m/s² pk
Model TLD356A16 | PCB Piezotronics
Model TLD356A16:Triaxial, high sensitivity, ceramic shear ICP® accel., 100 mV/g, 0.5 to 5k Hz, aluminum hsg, 4-pin conn., TEDS 1.0
Model 121A44 | PCB Piezotronics
Temperature Range (Operating)-65 to +250 °F-54 to +121 °C: Electrical: Output Polarity (Positive Pressure) Positive: Positive: Discharge Time Constant (at room temp) ≥1.0 sec: ≥1.0 sec: Excitation Voltage: 22 to 28 VDC: 22 to 28 VDC: Constant Current Excitation: 2 to 20 mA: 2 to 20 mA: Output Impedance: 100 Ohm: 100 Ohm: Output Bias ...
Model 8161-111A STRAIN GAGE SENSOR SIGNAL CONDITIONER ... - PCB
The 8161 series is designed to operate on a customer supplied DC power source with a voltage range of 10 to 28 volts. Screw terminals 1 and 2 are provided for power connections. Reference Figure 3. ... input, allowing the instrument sensitivity to be adjusted correctly.
UNIAXIAL STRAIN SENSOR - pcb.com
Sensitivity(± 20 %) 50 mV/µε 50 mV/µε ... Environmental Temperature Range(Operating) -65 to +250 °F -54 to +121 °C [3] Electrical Excitation Voltage 20 to 30 VDC 20 to 30 VDC Constant Current Excitation 2 to 20 mA 2 to 20 mA Output Bias Voltage 8 to 14 VDC 8 to 14 VDC Discharge Time Constant ≥ 150 sec ≥ 150 sec
PERFORMANCE SPECIFICATION TRIAXIAL ACCELEROMETER 65HT-XX - pcb.com
2.2 VOLTAGE SENSITIVITY . 2.2.1 Typical mV/g 0.5 1 10 . 2.2.2 Tolerance % ±10 ±10 ±10 . 2.3 FREQUENCY RESPONSE . 2.3.1 Amplitude, ±5% (Z axis) Hz 1 to 6000 ... divided by the unit's sensitivity. The negative range is limited to approximately 2 volts less than the bias voltage divided by the unit's sensitivity. Cable
Model TLD356A16 Triaxial, high sensitivity, ceramic shear ICP ... - PCB
Transverse Sensitivity ≤ 5 % ≤ 5 % Environmental Overload Limit(Shock) ± 7000 g pk ± 68,600 m/s² pk Temperature Range(Operating) -65 to +176 °F -54 to +80 °C Temperature Response See Graph See Graph [1] Base Strain Sensitivity 0.001 g/µε 0.01 (m/s²)/µε [1] Electrical Excitation Voltage 20 to 30 VDC 20 to 30 VDC