Search Results for netcomm ac1600 sensitive to voltage range
Model 356A33 | PCB Piezotronics
Model 356A33:Platinum Stock Products; Triaxial, ceramic shear ICP® accel., 10 mV/g, 2 to 7k Hz, titanium hsg, 1/4-28 4-pin conn.
Model 288D01 Mechanical Impedance Sensor Installation and ... - PCB
Sensitivity(± 10 %)(Acceleration) 100 mV/g 10.2 mV/(m/s²) Sensitivity(± 10 %)(Force) 100 mV/lb 22.4 mV/N Measurement Range(Acceleration) ± 50 g pk ± 490.5 m/s² pk Measurement Range(Force) ± 50 lbf pk ± 222.4 N pk Frequency Range(± 5 %)(Acceleration) 1 to 5000 Hz 1 to 5000 Hz Frequency Range(± 10 %)(Acceleration) 0.7 to 7000 Hz 0.7 to ...
TRIAXIAL ICP® ACCELEROMETER - PCB
Transverse Sensitivity ≤ 5 % ≤ 5 % Environmental Overload Limit(Shock) ± 5,000 g pk ± 49,050 m/s² pk Temperature Range(Operating) -65 to +250 °F -54 to +121 °C Temperature Response See Graph See Graph [1] Electrical Excitation Voltage 22 to 30 VDC 22 to 30 VDC Constant Current Excitation 2 to 20 mA 2 to 20 mA
Model 109C11 High pressure ICP® ballistic pressure sensor, 80k ... - PCB
specialized tests, including: sensitivity at elevated or cryogenic temperatures, phase response, extended high or low frequency response, extended range, leak testing, hydrostatic pressure testing, and others. For more information, contact your local PCB Piezotronics distributor, sales representative, or factory customer
Choosing an accelerometer - Wilcoxon Sensing Technologies
Answering these questions will help you figure out the sensitivity and acceleration range best suited to your application. For most rotating machinery, with overall vibration levels up to 10 g rms, a standard 100 mV/g accelerometer will capture the data you need. For these sensors, an 80 g range is typical and adequate for most applications.
Understanding Cold Temp, Bend, & Impact Ratings for Industrial Cables
Standard cold temperature ratings in industrial cables typically range from -25°C to -70°C (-13°F to -94°F), depending on the environment and application needs. For most outdoor installations and general industrial applications, cables rated for temperatures down to -40°C (-40°F) are commonly used, providing reliability for installations ...
Precision Industrial Accelerometers | PCB Piezotronics
The portion of the voltage used to power the accelerometer's amplifier is called the bias voltage and is usually in the range of 8-12 VDC. The voltmeter monitors this bias voltage and is useful for checking sensor operation. ... Sensitivity: (±5%) 100 mV/g; Sensitivity: (±5%)10.2 mV/(m/s²) Frequency Range: (±3dB)48 to 600000 cpm; Frequency ...
Model 137B29B | PCB Piezotronics
Measurement Range: 25 psi (173 kPa) ... (173 kPa) Sensitivity: (±15%)200 mV/psi (29 mV/kPa) Resonant Frequency: >=300 kHz ; Electrical Connector: BNC Jack ... For +10 volt output, minimum 26 VDC supply voltage required. Negative 10 volt output may be limited by output bias. [2] Typical. [4] See PCB Declaration of Conformance PS023 for details. ...
TEDS low-frequency accelerometer - Wilcoxon Sensing Technologies
Sensitivity, ± 5%, 25°C 500 mV/g Acceleration range 10 g peak Amplitude nonlinearity 1% Frequency response: –5% –10% –3 dB 0.6 - 850 Hz 0.4 - 1,500 Hz 0.2 - 3,700 Hz Resonance frequency 18 kHz Transverse sensitivity, max 7% of axial Temperature response: –50°C +120°C –8% +5% Power requirement: Voltage source
TEDS Sensors and technology - Introduction - PCB
The sensor will function as a normal measurement device and output an analog measurement signal when forward biased with a conventional positive voltage. The TEDS memory becomes accessible when the sensor is reversed biased and exposed to a negative voltage. The TEDS signal conditioner generates the reverse bias, or negative voltage pulses.
Product Data Sheet - All Sensors
The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage up to +16 V is acceptable. Equivalent Circuit Input Resittance 4.5 k ohm
PERFORMANCE SPECIFICATION ACCELEROMETER (MODEL 771-XXX-Y) RoHS COMPLIANT
VOLTAGE WITHOUT DAMAGE . For option ”R” supply voltage 7 Vdc . For option “U” supply voltage 45 Vdc . 4.7 INPUT VOLTAGE PROTECTION REVERSE POLARITY PROTECTED (For “U” option only) 4.8 INSULATION RESISTANCE 100 Meg Ohms minimum at 50 Vdc
UNDERSTANDING SOUND POWER AND MICROPHONE RESPONSE - PCB
The output voltage range of some preamplifiers may cause the . system to clip, reducing the usable high amplitude range of the microphone. Clipping occurs abruptly when the maximum voltage output of the preamplifier is exceeded. The upper limit of dynamic range is typically defined by either
ICP® PRESSURE SENSOR - pcb.com
Measurement Range(for ±5V output) 100 psi 690 kPa Sensitivity(-40 to +20 %) 50 mV/psi 7.3 mV/kPa Maximum Pressure(Total) 7,500 psi 51,713 kPa [1] Resolution 0.005 psi 0.035 kPa [2] Resonant Frequency ≥ 250 kHz ≥ 250 kHz ... Excitation Voltage 22 to 30 VDC 22 to 30 VDC
Model 8162-055A Strain Gage Sensor Signal Conditioner Installation and ...
Signal Conditioner. The first is a voltage output that is jumper selectable to either ±5 or ±10 volts. The desired voltage output is set by the position of the P2 Jumper. Jumping pins 1 and 2 will set the conditioner to ±10 V OUT. Jumping pins 2 and 3 will set the conditioner to ±5 V OUT. Adjust Zero Balance
Model 350B42 | PCB Piezotronics
Model 350B42:ICP® Triaxial shock accelerometer, 0.1 mV/g, 50k g range, mechanically isolated and electrically filtered, 5-ft integral cable
Model 209C11 | PCB Piezotronics
Temperature Range-65 to +250 °F-54 to +121 °C: Temperature Coefficient of Sensitivity: ≤0.05 %/°F: ≤0.09 %/°C: Electrical: Discharge Time Constant (at room temp) ≥1 sec: ≥1 sec: Excitation Voltage: 18 to 30 VDC: 18 to 30 VDC: Constant Current Excitation: 2 to 20 mA: 2 to 20 mA: Output Impedance: ≤100 Ohm: ≤100 Ohm: Output Bias ...
ICP® FORCE SENSOR - PCB
Temperature Range -65 to +250 °F -54 to +121 °C Temperature Coefficient of Sensitivity ≤ 0.03 %/°F ≤ 0.054 %/°C Electrical Discharge Time Constant ≥ 2,000 sec ≥ 2,000 sec Excitation Voltage 20 to 30 VDC 20 to 30 VDC Constant Current Excitation 2 to 20 mA 2 to 20 mA Output Impedance ≤ 100 Ohm ≤ 100 Ohm
PCB LOAD & TORQUE: A PCB GROUP COMPANY Load Cell Handbook
LOAD CELL HANDBOOK 4 PCB Load & Torque Division Toll-Free in USA 866-684-7107 716-684-0001 www.pcb.com A load cell is a device that converts a force or load into a measureable output. Load cells can come in multiple styles including hydraulic, pneumatic, strain gage, piezoelectric, and capacitance, but the
nrgSMART CONTROLLER - Amphenol Broadband Solutions
Voltage Range (nominal)-20V to -57V (nominal -48 VDC) Input Power Wire Size #18-12 AWG: Max. Operating Current: 3A (80% of 4A fuse rating) SD Card Capacity: 4 Gigabytes: SD Card Type: Micro SD: Grounding: Earth GND terminal bolts (with washers) for dual-hole compression lugs: Two pair of 1/4-20 threaded holes on 5/8-in. centers. Torque bolts ...