Search Results for npc-1220-030-a-1-s
1RU Power Panel Platform | Amphenol Network Solutions
We’re building something exciting! We’re building a new family with something for everyone. Our new 1RU DC Power product family has just the features that meet your needs, for your facilities, for both today and tomorrow.We’ve been delivering industry certified quality power products for decades and our customers say we’re really good at it.
Amphenol Industrial Operations
Amphenol Industrial Operations
Model 121A21 Industrial ICP® pressure sensor, 100 psi, 50 mV/psi, 1/4 ...
Industrial ICP® pressure sensor, 100 psi, 50 mV/psi, 1/4-18 NPT mtg thd, 2-pin MIL conn., case isolated Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com
IPC-620 Class III & ISO Compliant Cable Assembly for Industrial Markets
ISO 13485:2016 & ISO 9001:2008 Compliant Cable Assembly for Industrial Markets. Due to our extensive experience supplying wire harness solutions for industrial robots for factory automation, Amphenol DC Electronics has become an important partner for manufacturers of industrial equipment.
10167520-121211 | Amphenol Global Search | Amphenol
10167520-121211clf | Amphenol Global Search | Amphenol Relative accuracy ± 0.1 mbar • I2C interface • Operating range 1.7 ~ 3.6V • Small size package (2.0 x 2.5 x 1.0mm) • 8-HCLGA package • No External Components Required • Fully Calibrated and Compensated Applications • Pressure sensor for mobile devices (smart phones, smart ...
Soldier Worn Archives - Amphenol PCDAmphenol PCD
AN/PRC 117G & 152 Military Radio Data Connectors . Ideal for use with rugged laptops, intercom systems & FBCB2.
Overview - amphenol-ns.com
Network Solutions WaveTrax® and CommScope’s FiberGuide® Fiber Management System, CableLinks are articulating, snap-together links that create a flexible pathway for cabling while protectively maintaining bend radius. Ideal for vertical cable management on a frame or for negotiating tight areas, CableLinks fit in a variety of network ...
124019372112A | USB3.2 GEN1 | Amphenol
Amphenol is one of the leading manufacturers of USB3.2 GEN1. Contact us today for more details of Partnumber,124019372112A
Model 208A15 ICP® Force Sensor Installation and Operating Manual
1 1.0 INTRODUCTION . ICP force sensors incorporate a built-in MOSFET microelectronic amplifier. This serves to convert the high impedance charge output into a low impedance voltage signal for analysis or recording. ICP sensors, are powered from a separate constant current source, operate over long ordinary
AC-CP0020 | Amphenol Global Search | Amphenol
The NPA 201 is an absolute pressure sensor with digital output for low cost applications. A miniature 2.0 x 2.5 x 1.0mm HCLGA package ideally suits it for portable electronics and space constrained applications. Low current consumption of 250nA during Shutdown (Sleep) mode is ideal for battery and other low-power applications. ...
AC 6321-09 Apparatus Case - charlesindustries.com
Remove any locking device(s) located on the two locking latches. Rotate the two locking latch handles down towards the base of the apparatus case. Lift the cover up and over the apparatus case inner plug-in module. 2. Place the cover in a location where it will not be damaged. 3. Using the base mounting assembly as a template, mark the four ...
Part Number and Document Search - amphenol-ns.com
If you do not see what your are looking for please contact us and we will be happy to assist. For additional support please contact: support@amphenol-ns.com
ATCSeries - アンフェノールジャパン株式会社
electrical discontinuities longer than 1 microsecond Physical Shock: No unlocking, unmating or other unsatisfactory result during or after 50 g’s in each of three mutually perpen-dicular planes. No electrical discontinuities longer than 1 microsecond. MIL STD 202, Method 213, Condition “C”
00122520102 - Amphenol Air LB
The 1200 modules differ from the 1100 series by the inversion of the contact gender : they are fitted with socket crimp contacts. Complying with the ABS1569 standard, the 1200 modules are perfectly suited for signal or low current distribution, where sealing (IP66 / IP68 and IP69K), space and weight-saving are prime requirements.
Model 119C12 - PCB
%PDF-1.4 %âãÏÓ 11 0 obj > endobj 165 0 obj >/Font >/ProcSet[/PDF/Text]>> endobj 157 0 obj >stream H‰ìWË®å¶ ÜÏWè ¨ðMê È"ð2È* ‚ ñ"È"¿Ÿj’Õ ut¯Æ3ž‰ \ Öí£iñÑ ªj»ýðÉm¿ßÜö m÷.oÿÙœÝþ°ýéÏ›Ýþúéw?ü趿ý . ß>ý ^ ÿ¹-¤´g¿•rìqûËOííOŸLÙCÝððÛ??ý¨Îv3ÎïÅŸ ½ÝmÜúóƵž\ ~ç Ïú¸jL{Š[ ž]MÜÓfêîÏÎ ...
Model ABS1200H/VF Horizontal & TrueFlex Broadband Digital Splitter ...
dB Max Peak to Peak 5-1218 1.0 Isolation dB Min 5-10 22 11-85 32 86-870 25 871-1002 22 1003-1218 20 Return Loss dB Min (In and Out) 5-1002 20 1003-1218 18 Shielding dB Min 5-1002 120 1003-1218 110 Surge Withstand Input 6kV B3 Combination Wave (IEEE C62.41) Output 6kV A3 Ring Wave (IEEE C62.41) ...
Interconnect Solutions for Naval & Marine - amphenol-socapex.com
- Display 1.4 protocol - Transmission bandwidth : 32.4 Gbit/s with 8.1 Gbit/s per lane - Can support 8K UHD (7680 × 4320) at 60 Hz or 4K UHD (3840 × 2160) at 120 Hz HDMI FTV Tri Start Thread coupling mechanism decoupling device. Shell size 17. tools required. Data Transmission: HDMI 2.0 protocol : - Transmission bandwidth : 18 Gbit/s
Catalog - amphenol-antennas.com
VSWR 1.5:1 maximum Maximum power 300 W Connector N plug + 3.5 m RG214u downlead Operating temperature -30° to +55° C -22° to +131° F Lightning protection All conductive components bonded to ground. Ma e a Dipole Full half wave dipole made from 19.05 mm diameter, 2.03 mm thick aluminium tube. ...
Max-M12 - Amphenol Industrial Operations
Part 1: Tools Part 2: Cable Installation Instructions Contact Crimping Tool: DMC AF8 M22520/1-01 Install Tool: TOOL-754720-020 for size 20 contact TOOL-754721-024 for size 24 contact Contact Removal Tool: TOOL-754593-020 for pin and socket contacts Step 1: Strip the cable insulation, length is about 15mm. 3
CABLE ASSEMBLY INSTRUCTIONS - amphenolrf.com
STEP 1. All parts of the connector are shown. A crimp tool is necessary to complete the connection. STEP 2. Strip the cable inner conductor, dielectric, braid, and jacket as per “RECOMMENDED CABLE STRIPPING DIM’S” in catalog. STEP 3. Insert inner conductor into the CONTACT PIN, crimp it with the crimp tool as shown. Then slide the FERRULE ...