CUSTOMER OUTLINE DRAWING - amphenolrf.com
(p/n per table below). with dies firmly affixed in tool on the die mounting surfaces, close the tool fully (until the ratchet releases) with 25-35 lbs,hand force the dies must be 'butted' (touching both front & rear surfaces). the ratchet adjuster wheel should be positioned in the center indent (+/- one indent position) date code 2.
B A1 - Amphenol Sine
values: 1.9-2.2 n.m main polarizing keyway 110°ref 110°ref 63.0 78.2±0.5 size 16 contacts 7 (23 places) 7 size 12 contacts (4 places) weight:63.5g notes: unless otherwise specified 1. material: housing: thermoplastic; black seal: silicone rubber threaded insert: stainless steel 2. modifications: backshell ring adapter (bra); reduced dia ...
FAQ - Amphenol Socapex
The « IP » defines the resistance of the product against solids (first number) and liquids (second number).
When mated, the Powersafe is defined as IP68.
CUSTOMER OUTLINE DRAWING - Amphenol RF
(p/n per table below). with dies firmly affixed in tool on the die mounting surfaces, close the tool fully (until the ratchet releases) with 25-35 lbs,hand force the dies must be 'butted' (touching both front & rear surfaces). the ratchet adjuster wheel should be positioned in the center indent (+/- one indent position) date code 2.
Amphenol Advanced Sensors NTC Thermistor Resistance - Temperature Data
Amphenol Advanced Sensors NTC Thermistor Resistance - Temperature Data Amphenol Thermometrics (UK) Ltd +44 (0) 1823 335200 Customer: Amphenol Generic Pipeclip Amphenol Ref: JS9218 Thermistor resistance calculated from R / R25 = exp ( A0 + A1/T + A2/T^2 + A3/T^3 )
00551669200 - Amphenol Air LB
Faston type relay socket 6RT bistable 10A with directional posts Without fixation set Marking P/N + Date code Standard polarizers
Psyclone™ Protimeter Thermo-Hygrometer Operating Manual
Protimeter Psyclone Page 1 Table 1: Psyclone Measurement Parameters Parameter Symbol % Relative Humidity % RH 1Grains per pound GPP 2Grams per kilo Gram g/kg Dewpoint Temperature DEW POINT
PROTIMETER - amphenol-sensors.com
relationship between the relative humidity (r.h) of air and the moisture content of typical softwoods. The horizontal lines show the typical range of hu-midities met in various circumstances. Wood kept in these environments will gradually come into equilibrium at the moisture content levels indicat-
NovaSensor P111 Medium Silicon Pressure Sensor Die
Parameter Value Units Notes General Pressure Range 100 KPa -15 psi (-1 bar) 200 KPa -30 psi (-2 bar) 700 KPa -100 psi (-7 bar) Maximum Overpressure 2X rated pressure Electrical @ 72°F (25°C) unless noted Excitation 1.0 mA 10 VDC Maximum Input Impedance 5000 ±20% Ω Output Impedance 5000 ±20% Ω Environmental Temperature Range
NovaSensor P111 Medium Silicon Pressure Sensor Die
Parameter Value Units Notes General Pressure Range 100 KPa -15 psi (-1 bar) 200 KPa -30 psi (-2 bar) 700 KPa -100 psi (-7 bar) Maximum Overpressure 2X rated pressure Electrical @ 72°F (25°C) unless noted Excitation 1.0 mA 10 VDC Maximum Input Impedance 5000 ±20% Ω Output Impedance 5000 ±20% Ω Environmental Temperature Range
Telaire T7000 Series - amphenol-sensors.com
0 – 2000 ppm: ±0.1% of reading per °C or ±2 ppm per °C, whichever is greater, referenced at 25°C. 2000 – 10000 ppm: ±0.2% of reading per °C referenced at 25°C Pressure Dependence 0.13% of reading per mmHg (corrected via user input for elevation) Response Time <60 seconds for 90% of step change Warm-Up Time <60 seconds at 72°F (22°C)
Type S/AS/ES Thermometrics Precision, Ultrastable NTC Temperature Standards
The nominal resistance values are shown below: Type Resistance In Ohms 0°C 25°C 60°C 100°C “AS” & “S” 14250 5000 1458 – “AS” & “S” 11400 4000 1166 – “ES” 28500 10000 2915 925 Read-Out Devices Thermometrics’ Temperature Standards are designed for use with any suitable resistance measuring instrument.
Battery pack temperature sensor - amphenol-sensors.com
R @ 25°C 10,000 ohms ±1% B (25/85) 3435 Operating Temperature Range-40°C to 150°C Storage Temperature Range: -40°C to 150°C Response Time < 15 seconds Temperature Accuracy ± 0.2°C from 0 to 70°C Housing Material Tyco Ring Terminal # 322447, #4 stud ring tongue terminal Wire #22 (7x30) 600 V Belden 83005 wire, PTFE Length: 1000mm
Amphenol
Page 2 of 11 Protimeter Speedy March 2014 Moisture Test Procedure for Standard Size Speedy A standard size speedy is shown in the photograph to the left.
Amphenol
Page 2 of 11 Protimeter Speedy March 2014 Moisture Test Procedure for Standard Size Speedy A standard size speedy is shown in the photograph to the left.
Amphenol
Page 2 of 11 Protimeter Speedy March 2014 Moisture Test Procedure for Standard Size Speedy A standard size speedy is shown in the photograph to the left.
Type S/AS/ES Thermometrics Precision, Ultrastable NTC Temperature Standards
The nominal resistance values are shown below: Type Resistance In Ohms 0°C 25°C 60°C 100°C “AS” & “S” 14250 5000 1458 – “AS” & “S” 11400 4000 1166 – “ES” 28500 10000 2915 925 Read-Out Devices Thermometrics’ Temperature Standards are designed for use with any suitable resistance measuring instrument.
Amphenol
Page 2 of 11 Protimeter Speedy March 2014 Moisture Test Procedure for Standard Size Speedy A standard size speedy is shown in the photograph to the left.
HumiTrac XR General Eastern Dew Point, Enthalpy, Wet Bulb, and ...
HumiTrac™ XR Telaire® Dew Point, Enthalpy, Wet Bulb, and Temperature Transmitters Features • Microprocessor-based signal processing • Excellent accuracy • Weather resistant duct and outside air
TV-CTV - D38999 Series III - 38999 Series | Amphenol Socapex
The TV-CTV D38999 Series III is a MIL-DTL-38999 series III qualified connector designed for use in harsh military and industrial environments. This series offers a wide range of contact arrangements and shell types, making it an ideal choice for applications that require maximum weight and space savings.