Search Results for pt02c-20-41px003
Model 2301-01A | PCB Piezotronics
Model 2301-01A:PCB L&T Reaction Torque Transducer, 2,000 in-lb/167 ft-lb (226 N-m) rated capacity, 50% static overload protection, 4-in (101.6 mm) Ste
Model 356A32/NC Platinum Stock Products; Triaxial, mini (5 gm ... - PCB
Model 356A32/NC Platinum Stock Products; Triaxial, mini (5 gm) high sensitivity, ICP® accel., 100 mV/g, 1 Hz to 4k Hz, titanium hsg, no mating cable supplied, mini 4-pin conn
ICP® FORCE SENSOR - PCB
Model Number 208C03 ICP® FORCE SENSOR Revision: K ECN #: 51420 Performance ENGLISH SI Sensitivity(± 15 %) 10 mV/lb 2,248 mV/kN Measurement Range(Compression) 500 lb 2.224 kN Measurement Range(Tension) 500 lb 2.224 kN
Model J356A43 | PCB Piezotronics
Model J356A43:Triaxial ICP® accelerometer, 10 mV/g, 500 g, 1/4-28 4-pin connector, Adhesive mount, TEDS 1.0, Ground isolated
Temposonics II
5 DIGITAL SYSTEM ADJUSTMENTS 20 6 ELECTRONIC CONNECTIONS 21 6.1 General 21 6.2 Transducer Connections 22 6.3 Digital Counter Card Connections 24 6.3.1 Latch Pulse 25 6.3.2 Protocol 25 6.3.3 Latch Inhibit Input 25 6.4 Counter Cards - Natural Binary Output 26 6.5 Counter Cards - BCD Output 29 6.6 System Calibration 32
Model J320C33 ESS high sensitivity, quartz shear ICP® accel, 100 ... - PCB
Model J320C33 ESS high sensitivity, quartz shear ICP® accel, 100 mV/g, 1 to 4k Hz, 10-32 side conn. (to +325 F) ground isolated Installation and Operating Manual
Model 356B20 Triaxial, miniature (4 gm), ceramic shear ICP ... - PCB
Constant Current Excitation 2 to 20 mA 2 to 20 mA Output Impedance ≤ 200 Ohm ≤ 200 Ohm Output Bias Voltage 7 to 12 VDC 7 to 12 VDC Discharge Time Constant 1.5 to 3.0 sec 1.5 to 3.0 sec Settling Time(within 10% of bias) <10 sec <10 sec Spectral Noise(1 Hz) 9000 µg/ √Hz 88,290 (µm/sec 2)/ √Hz [1]
Model HT356B21 | PCB Piezotronics
Model HT356B21:Platinum Stock Products; Triaxial ICP® accel, 10 mV/g, 500 g, mini 4-pin conn, to +325 F (+163 C), 10 ft cable included
ICP® PRESSURE SENSOR - pcb.com
Model Number 102B03 ICP® PRESSURE SENSOR Revision: B ECN #: 53357 Performance ENGLISH SI Measurement Range(for ±5V output) 10,000 psi 69,000 kPa Sensitivity(± 0.03 mV/psi) 0.5 mV/psi 0.07 mV/kPa
Model 393A03/ACS-23 Seismic, ceramic shear ICP® accel., 1 V/g, 0 ... - PCB
Model 393A03/ACS-23 Seismic, ceramic shear ICP® accel., 1 V/g, 0.5 to 2k Hz, 2-pin top conn with low frequency calibration Installation and Operating Manual
PSMDU48P200-X SERIES
10 OUTPUT 20 INHIBIT 30 SENSE RTN 15 1 30 16. www.amphenol-socapex.com Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex PSMDU48P200-X SERIES 4 Functions and Signals INHIBIT signal The INHIBIT signal is used to turn the power supply ON and OFF. ...
HY-TREX - TPC Wire
hy-trex® motor power cable – unshielded part no. legacy part no. cond size number of conductors cond stranding nom o.d. (in.) weight (lbs/1000') bend radius (in) gland* awg equiv p/n
Absolute, Non-Contact Position Sensors Data Sheet G ... - Temposonics
24 VDC (-15 / +20 %); UL Recognition requires an approved power supply with energy limitation (UL 61010-1), or Class 2 rating according to the National Electrical Code (USA) / Canadian Electrical Code. up to -30 VDC up to 36 VDC 100 mA typical < 0.28 Vpp 500 VDC (DC ground to machine ground)-JOFBSJUZ QSPUPDPM FYBNQMF Sensor Temposonics® (1 ()
HDMI connection system for harsh environment - Amphenol Socapex
www.amphenol-socapex.com Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex
Model 103B01 Acoustic ICP® pressure sensor, 3 psi, 1500 mV/psi ... - PCB
will show a reading of approximately 20% of F.S. on these meters. This puts it at the lower limit of the green (or normal) area of the meters. This is normal and in no way indicates faulty operation. 4.0 OUTPUT SIGNAL The output signal from the 103A Series is a voltage proportional to input pressure. The polarity is
APPLICATION NOTE - Amphenol Ardent Concepts
APPLICATION NOTE Ardent Concepts, Inc. 4 Merrill Industrial Drive Hampton, NH 03842 (603) 474-1760 Sales: [email protected] Technical: [email protected]
AE-AN-TR-016 - TR MULTICOAX SERIES - ANATOMY OF TR
o SMA M/F up to 20 GHz (TR20) o SMK (2.92 mm) M/F up to 40 GHz (TR40) o SMV (1.85 mm) M/F up to 70 GHz (TR70) o Consult factory for custom applications • PEM Nuts- o Press into the back of the stiffener block if the PCB thickness is greater than 93 mils, we recommend just the PEM nuts and no stiffener block. This helps
Absolute, Non-Contact Position Sensors Data Sheet G-Series Analog or ...
24 VDC (-15 / +20 %); UL Recognition requires an approved power supply with energy limitation (UL 61010-1), or Class 2 rating according to the National Electrical Code (USA) / Canadian Electrical Code. up to -30 VDC up to 36 VDC 100 mA typical < 0.28 Vpp 500 VDC (DC ground to machine ground)-JOFBSJUZ QSPUPDPM FYBNQMF Sensor Temposonics® (1 ()
Model 201B03 ICP® quartz force ring, 500 lb comp., 10 mV/lb ... - PCB
cost, 2427 VDC, 2- -20 mA constant current supply. Figure 1 schematically illustrates a typical ICP sensor system. PCB offers a number of AC or battery-powered, single or multi-channel power/signal conditioners, with or without gain capabilities for use with force sensors. In addition, many data
Model J356A44 Triaxial ICP® accelerometer, 50 mV/g, 100 g, 1/4 ... - PCB
Excitation Voltage 20 to 30 VDC 20 to 30 VDC Constant Current Excitation 2 to 20 mA 2 to 20 mA Output Impedance ≤ 200 Ohm ≤ 200 Ohm Output Bias Voltage 8 to 12 VDC 8 to 12 VDC Discharge Time Constant 0.8 to 2.4 sec 0.8 to 2.4 sec Settling Time(within 10% of bias) ≤ 5 sec ≤ 5 sec Spectral Noise(1 Hz) 200 µg/√Hz 1,962 (µm/sec2)/√Hz [1]