Search Results for section cables
2M805 2M804 2M803 2M801 - Amphenol Aerospace
56 Contact Us: 800-678-0141 • www.amphenol-aerospace.comContact Us: 800-678-0141 • www.amphenol-aerospace.com 2M805 Series of Hermetic Receptacles provide superior sealing of 1x10-8 cc/second helium leak rate and are 100% tested prior to shipping. This superior sealing is
Model 629A11 Triaxial, industrial, ceramic shear ICP® accel., 100 mV/g ...
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
terminal lug | Amphenol Global Search | Amphenol
Whether your need is for a highly customized terminal lug for a unique installation, or a standard terminal for rapid entry into service, CarlisleIT provides the solution. (1) One- and two-hole terminal lugs, (2) crimped terminal lug, (3) integral oxide breaker location and (4) typical cross-section example.
Sensor Design Parameters for Underwater Applications
Another and often a more important reason to waterblock or void fill a cable cross section, is to provide the crush resistance required to operate as specified at depth. Figure 11: South Bay Waterblock Cable Cross Section View [7] The cable material must also be compatible with thermoset materials used for attachment to the sensor housing.
Amphenol Network Solutions > Easily add a new section onto your ...
The two-inch WaveTrax Intersection provides a perpendicular transition on a fiber cable raceway. Product #: 027-2000-4230. Trough Width . Exit Width . Qty: Non-cancelable and non-returnable. Login for price. Downloads - CommScope's FiberGuide® to WaveTrax® Cross Reference ...
Electromagnetic shakers operating guide - Wilcoxon Sensing Technologies
6. All cables must be connected between the power amplifier, matching network and shaker before electrical power is connected. Inspect for frayed or cut cables prior to operation. 7. Wear hearing protection when driving piezoelectric shakers at high levels and high frequencies. 8. Do not expose this equipment to rain or moisture. 9.
II - Temposonics
10.1 Preparing Cable for Connection to the AOM 25 10.2 J1 Installation Wiring 26 10.3 J1 Connections for AOM 27 10.4 J1 Connection to AOM with MSConnectors 29 ... Using the principle of magnetostriction (see Section 1.1, below), the Temposonics II LDT measures the time interval between the initiation of an interrogation pulse and the detection
Model 602D01 Platinum Stock Products; Low profile, industrial ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model TO608A11 Platinum Low-cost Industrial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Part Search Results
Scorpion™ Catalog Revision: B6 25/01. The most versatile modular power/signal connector on the market offering design flexibility . SP8 End Module Update
27-pin | Amphenol Global Search | Amphenol
Buy 10ft Amphenol CS-DSLSZH25MM-010 Cables Direct from the Factory at Cables on Demand. Amphenol 25-pin (DB25) Low Smoke Zero Halogen D-Sub cables protect your personnel and equipment from the harmful environmental effects of wire combustion, such as toxic and corrosive PVC based fumes.
Omni Antennas CXL 2-5HD/... - AMPHENOL PROCOM
Please Note. When using the CXL 2-5HD/… at windy locations where wind speeds of more than 150 km/h can be expected, the antenna must be mounted on the side of the mast and the top section of the glass fibre tube stabilized with a bracket.
Omni Antennas 422x.03-405-Txx - amphenolprocom.com
Mounting Section: Al. tube 63.5 mm dia. x 350 mm long: Dimensions: 1600 (l) x 53 (dia.) mm / 62.99 x 2.09 (dia.) in. Wind Load: 142 N (160 km/h) Weight: Approx. 4 kg / 8.82 lb. ... Amphenol Procom offers several Corrugated Cables like Super Flexible- and Cobber Cables. All are of the highest quality on the market. See our collection. Explore ...
MicroSpace™ High Voltage selective loaded Crimp-to-Wire Connector ...
MicroSpace™ High Voltage Crimp-to-Wire connectors meet LV214 Severity-2 and operate at 3.81mm, 6.35mm, and 8.89mm pitch, supporting 400V, 800V, and 1200V.
BarKlip BK100 I/O | Power Solutions | Amphenol
Amphenol's BarKlip BK100 I/O provides a convenient method of distributing up to 100A between busbars, cables and circuit boards. It features 12 fully independent cantilevered beams, providing a true compliant spring to adjust for variations in busbar
backshell | Amphenol Global Search | Amphenol
When your cable assembly includes circular connectors from Amp, Conxall, or Molex, we can overmold a protective backshell. This protective backshell application will provide superior strain relief, improved environmental protection, and enhanced appearance. By utilizing the right angle, version wire and cable clearance can be improved in tight ...
MS27488-20-2 | Amphenol Global Search | Amphenol
Search Results for ms27488-22-2 CHARGE AMPLIFIERS Convert high impedance output from charge-mode sensors to low-impedance voltage or current output Can be paired with charge-mode accelerometers and ... up 11% compared to prior year GAAP and Adjusted Operating Margin of 20.6% and 20.9% Record Operating and Free Cash Flow of $705 million and $613
Amphenol Network Solutions > Products | Amphenol Network Solutions ...
22425 East Appleway Ave #11 Liberty Lake, WA 99019 Phone: 509.926.6000 Email: getinfo@amphenol-ns.com
Model M603M170 General purpose industrial ceramic shear ICP accel ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
NX-A11YAR- P16XCD0-0000 - Amphenol NEXUS Technologies
Images Type of Connector Straight Plug Size 1 Number of Contacts 16 Keying Brown Contact Type Pins Contact Diameter 0.5 mm Cable Diameter 3.2 – 6.5 mm Insulator Material PEEK Wire Cross Section 26 AWG Termination Type Solder Termination Diameter 0.65 mm Data Transmission NA Degree of Protection IP6K8 / IP6K9K Operating Temperature -51°C – […]