Search Results for section cables
74868 - Amphenol RF
the c04 cable group covers both standard and low-loss rg-58 cable. when using the low-loss rg-58 cable, the foil should be removed over the dielectric for ... section a-a scale 1.500 227-1522 plunger tool 227-1520 cone tool o-ring section a-a scale 2.500. author: amphenol rf created date:
EXCEL|MATE - Amphenol PCD
Part number Conductor cross section (mm2) Cable OD (mm) HVPTB 2 A 03 2.5 / 3.0 5.2 ± 0.2 PANEL MOUNTINg DIMENSIONS Excel|Mate PT (HVPT B 2A) 15 HVPC PASS-THROUgH KEY FEATURES Easy to install, reliable connection Sealing, IP67 (mated), IP6K9K Multiple coding positions 360° shielded from wire to device Economical
Whip Antennas MU 4-ZG/... - amphenolprocom.com
Choice between ZG-mount with FME-connection (supplied without cable) or ZGP4-mount with 4 m factory fitted cable (terminated with FME-connector). ... The antenna whip comprises a ¼ section, a phase shifting coil, and a ½ section. The ZG-mount is designed for mounting from the outside in a 21 mm dia. hole on horizontal surfaces as e.g. roof ...
Models 2680M1/2685M1 - PCB
04 1 1 2680 input cable 7. 04 1 1 2 Input cable length. 7 04 1 2 2685 input cable. 8 04 1 2 1 Input cable length 8 ... instructions in section 7.1 of this manual. It is recommended that an : applications engineer be contacted prior to returning the unit since many
Cable Management Vulko-Wrap Self-Vulcanizing Insulating Wrap TM - TPC Wire
Amphenol TPC Wire Cable / SA -521-5 / Canada -55-122 / Mexico 1--2-1 / tpcwirecom efiatns suet t ane Fr ete sefiatns an aaat as ur aes eresentate r a ... Triangular Cross-Section with Color Guideline Allows even thickness for uniform high dielectric strength. Specially Compounded, Synthetic Silicone Elastomer
Marport Compact System
Labels indicate to which cable correspond each connector. 1. Install the mounting plate vertically on a wall using the 5 screw holes. 2. Connect the power supply to an outlet with a voltage between 100 and 240 V. 3. Connect the hydrophone(s) cable(s) to the junction boxe(s). 4.Connect the screen(s) (up to two) to the HDMI port(s) on the computer.
GS-12-650 PRODUCT SPECIFCATION - Amphenol CS
7.4 Cable Strain Relief (Un-mated) The cable shall withstand a minimum force of 100 N when an axial load is applied directly to the cable. Force shall be applied at a rate of 25mm per minute. 7.5 Wire Flex Testing shall be performed in accordance with EIA-364-41 with the exception of section 4.2.5. The cable
Model 623C61 High-freq., industrial, ceramic shear ICP® accel, 100 mV/g ...
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model 601A02/ICS-14 ACCELEROMETER LOW FREQUENCY 500mV/G Installation ...
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
pld-14 | Amphenol Global Search | Amphenol
Search Results for pld-14-3-20241103-021 132203 | Amphenol Global Search | Amphenol In early 2018, a partnership and project collaboration between Amphenol RF and Amphenol Custom Cable began with one goal: to merge the specialties from both business units and introduce to the market an easy-to-use online RF cable assembly builder that would ...
HDB3/HSB3 Connectors | Products | Amphenol Aerospace
Fiber Optic Cable Assemblies Rugged Active Optical Cables High-Speed Digital Data Cables ... HDB3/HSB3 Catalog Section Incorporates a higher density contact pattern and lower mated height than Amphenol’s standard low mating force rectangular connectors. ...
Radio Frequency Connectors | Products - Amphenol
RF connectors are typically used with coaxial cables and are designed to maintain the shielding that the coaxial design offers. Available in SMA, N-Type, with various termination choices. ... SV Microwave’s VITA product line is the latest addition to the RF / coaxial section of the VPX platform.
spectrum | Amphenol Global Search | Amphenol
The radio spectrum refers to the section of the electromagnetic spectrum that holds all possible radio frequencies ranging from 3 kHz to 300 GHz. ... with a variety of cable and connector options. All G, GM, and G-AS series mounts feature standard 1-1/8″-18 thread.
fc connectors | Amphenol Global Search | Amphenol
Amphenol FO-DUALFC9125-005 FC-FC - Duplex Single-Mode 9 / 125 Fiber Optic Patch Cable (OFNR Riser) - 2 x FC Male to 2 x FC Male 5m; Code: FO-DUALFC9125-005 Buy 5m Amphenol FO-DUALFC9125-005 Cables Direct from the Factory at Cables on Demand. 100% optically tested duplex single-mode 9/125 fiber optic patch cables by Amphenol meet and exceed industry standard specifications for insertion loss ...
NEXUS
with cables approx .275 outside dia. 3) the solder terminals ech will accept two stranded conductors of 404 circular mils (24 gage, 41 strands of 40 awg) 4) each conductor is of one piece construction. ... section w-w tj-105-1 contact #1 tj-105-4 contact #4 tj-105-3 contact #3 tj-105-2
Model M604B31 Low-cost Triaxial Industrial ICP® Accelerometer ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
Model M607A11/030BZ Platinum Swiveler® Industrial ICP ... - PCB
when driving long signal cables (see Section 5). Decoupling of the data signal occurs at the output stage of the signal conditioner. A 10 to 30 µF capacitor coupled with a resistor shifts the signal level to essentially eliminate the sensor bias voltage. The result is a drift-free AC mode of operation. 3.0 OPTIONAL FEATURES
T ERIES LS - Temposonics
W IRING 5 EXTENSION CABLE WITH CONNECTOR(S) FOR D6 CONNECTION STYLE: SENSOR CONNECTION TYPE D6 = Female connector for sensors with D6 connector (straight exit) DA = Female connector for sensors with D6 connector (90º exit) CABLE LENGTHS For standard length cables up to 100 ft. 005= 5 ft. 015= 15 ft. 025= 25 ft. 050= 50 ft. 100 = 100 ft. For custom length cables over 100 ft.
cad | Amphenol Global Search | Amphenol
E E Y Y SECTION Y-Y - Amphenol Sine section y-y iso view cable clamp (scale 2 : 1 ) y y 4 50440055-300 thermoplastic backshell - black 1 3 50260024-500 thermoplastic cable clamp - black 1
M333 Series - amphenol-aerospace.com
Cable Injection), RE101, RE102, RS101, RS103. (Sur-face-Ships and Submarine-Internal application). DC Magnetic Field Tolerates 1600 A/m (per MIL-STD-1399 Section 70) WEIGHT AND SIZE In accordance with DWG M333004 (19” Rack-mount, 2U high, 22” deep, weighs 100 Lbs) CONNECTORS AND PIN OUT: