Search Results for vibro pipe
cmm composi | Amphenol Global Search | Amphenol
75P Clamp was designed as a one-for-one replacement to outperform industry-standard metal clamps (i.e. AS21919). Featuring benefits such as a locking feature, butterfly stacking, weight savings, durable PEEK polymer band material, and multiple cushion material options that are non-conductive and non-corrosive, a versatile solution for anyone looking to reduce weight and installation time.
Handheld vibration meter - wilcoxon.com
Handheld vibration meter Accessories supplied: MAC002 protective boot with magnets; MAC003 carrying case with insert; extended stinger Key features • Versatile meter for walkaround monitoring programs • Built-in ISO alarms • 100 and 800 line FFT spectrum • BDU reading • High performance accelerometer with stinger
Marine Antennas CXL 1800-8C - amphenolprocom.com
Vertically polarized, omnidirectional base station and marine antenna. Approximately 8 dBd gain. Provided with the “C” mounting bracket – a universal fixation bracket made of epoxy-coated seawater resistant aluminium.
PCB Piezotronics | Measure vibration, pressure, force, and more
Created Date: 10/24/2005 2:24:05 PM
Indoor Air Quality - Amphenol Sensors
Indoor Air Quality - Amphenol Sensors
Helicopters Archives - Page 7 of 7 - Amphenol PCDAmphenol PCD
Customizable solution ensuring pipes and tubes are properly secured throughout their entire length. Design Services Customize any solution using PCD’s in-house FEA and additive manufactured prototyping to accelerate iterative design cycles and concept validation.
micro usb | Amphenol Global Search | Amphenol
Features & Benefits: Available in 10 sizes for cable or pipes diameters from 5 to 25.4 mm. Weight from 1.4g to 4.9g. Weight saving up to 24% compared to legacy CC5516A composite clamps, and up to 73% compared to metallic NSA5516 clamps ... 2 HVM200 HUMAN VIBRATION METER FEATURES Control and view data from a mobile app (Android™ or Apple iOS ...
APXVBB4L26H2_43-C-I20, -A-I20, -C-I20S, -A-I20S
12-Ports, X-Pol, Panel Antenna, 2.7m, 2x 690-960/4x 1695-2690MHz, 65deg, Integrated RET, Site Sharing Optional
Marine Antennas CXL 1800-8C - amphenolprocom.com
Vertically polarized, omnidirectional base station and marine antenna. Approximately 8 dBd gain. Provided with the “C” mounting bracket – a universal fixation bracket made of epoxy-coated seawater resistant aluminium.
Marine Antennas CXL 1800-6LW - amphenolprocom.com
Vertically polarized, omnidirectional base station and marine antenna. Approximately 5.4 dBd gain. Provided with the sturdy “LW” mast mount – a lightweight, multipurpose, epoxy-coated mounting bracket made of non-corrosive aluminium.
BroadbandMT Showcase - Charles Industries, LLC • An Amphenol Company
Riser Pipes & Wire Guards. Riser Pipes & Wire Guards; Fiber Optic Solutions. Fiber Optic Solutions; Fiber Splice Closures – Outdoor. Fiber Aerial Solutions (CFAS) Fiber Sealed Drop Closures - Miniature (FSDCM) Fiber Sealed Drop Closures (FSDC) Fiber Optic Dome Closures (FODC) Fiber Drop Repair Closures (FDRC) Fiber Optic Round Closures (FORC)
INNOVATIONS IN AUDIO • AUDIO ELECTRONICS • THE BEST IN DIY AUDIO
Kjær Sound & Vibration (B&K) 4133 lab micr ophone (NIST-traceable), and a B&K 4231 SPL calibrator. Frequency response and polar measurements are taken using a quasi-anechoic method, a Farina chirp test signal that yields an impulse response, which can be gated to remove room reflections. This provides
TRIAXIAL ICP® ACCELEROMETER - PCB
Model Number 356A44 TRIAXIAL ICP® ACCELEROMETER Revision: E ECN #: 53976 Performance ENGLISH SI Sensitivity(± 10 %) 50 mV/g 5.1 mV/(m/s²) Measurement Range ± 100 g pk ± 981 m/s² pk Frequency Range(+/- 5 %) 0.7 to 7,000 Hz 0.7 to 7,000 Hz
M81714/67 Series II Socket Junction Modules Socket Junction Module ...
Socket Junction Modules www.amphenolpcd.com Milaero@amphenolpcd.com 1-978-624-3400 72 Cherry Hill Drive Beverly, MA 01915 Military P/N APCD Mounting Pos.*
Military Avionics Archives - Page 3 of 6 - Amphenol PCD
Provide strain relief, support weight saving initiatives and withstands high vibration and corrosive environments. Crimp Ring Adapter Cable terminations where heat shrink boots are used may require provision for terminating the screens.
TRIAXIAL ICP® ACCELEROMETER - PCB
Model Number 356A44 TRIAXIAL ICP® ACCELEROMETER Revision: E ECN #: 53976 Performance ENGLISH SI Sensitivity(± 10 %) 50 mV/g 5.1 mV/(m/s²) Measurement Range ± 100 g pk ± 981 m/s² pk Frequency Range(+/- 5 %) 0.7 to 7,000 Hz 0.7 to 7,000 Hz
CHARGE OUTPUT PRESSURE SENSOR - PCB
Maximum Vibration 2,000 g pk 19,614 m/s² pk Maximum Shock 50,000 g pk 490,330 m/s² pk Electrical Output Polarity Negative Negative Capacitance 20 pF 20 pF [2] Insulation Resistance(at room temp) ≥ 1E12 Ohm ≥ 1E12 Ohm Physical Sensing Element Quartz Quartz Housing Material C-300 C-300 Diaphragm C-300 C-300 Sealing Epoxy Epoxy
Model 3741B1230G DC Response Accelerometer Installation and ... - PCB
Whole-Body Vibration Studies Lower range, higher sensitivity DC accelerometers, allow for simple 2 g turn-over testing as a means of determining the health of the unit prior to use. By simply placing the unit in a +1g position and noting the output, then turning the unit on its side to the null position and noting the 0g
Marine Antennas CXL 1800-1LW - AMPHENOL PROCOM
CXL 1800-1LW is a 0 dBd, vertically polarized, omnidirectional base station and marine antenna for the 1800 MHz band. The carefully designed, broad-banded antenna element is sealed in a high-quality, glass fibre tube with low wind-load, which will ensure performance undisturbed by corrosive environments.
antenna | Amphenol Global Search | Amphenol
CRO1-VU0, In-Building Antenna, 1-Port, Ceiling Mount Omni, Transparent, Rectangular, HPOL, 360°, 617-5925 MHz, 3.6-5.4 dBi, SISO, Thru-mount