Search Results for 420 : 60
Unity-Gain, Omnidirectional Base Station and Marine Antenna for the 450 ...
CXL 70-1LW/h: 420 - 470 MHz CXL 70-1LW/hs: 460 - 510 MHz Antenna Type Coaxial dipole, broad-banded Max. Input Power 200 W Polarisation Vertical Pattern Type Omnidirectional 3 dB Beamwidth, E-Plane 80 ° 3 dB Beamwidth, H-Plane Omnidirectional Impedance 50 Ω Gain 0 dBd (2.2 dBi) VSWR < 1.5:1 Bandwidth 50 - 60 MHz dep. of model Antistatic Protection
HYBRIFLEX Optical Fiber & Power Cables - Hybrid
HB012-05U1S1-100F HYBRIFLEX® Hybrid Feeder Cabling Solution, 1x1, 1/2”, 1 pair 10AWG, 1 pair Single-Mode Fiber with DLC-DLC Connectors, 100 ft . Length,m (ft): 30.4 (100) F/O Cable Type: G657-A2 Single Mode, Bend Tolerant; Number of F/O Pairs: 1; Fiber Termination End 1: DLC Connector; Fiber Termination End 2: DLC Connector; Size: 1/2; Number of DC Pairs: 1
Kaye LTR-40/140 - kayeinstruments.com
HTR-420; HTR-400; Banho Líquido Kaye CTR. CTR-25; CTR-40; CTR-80; Comparador LN2; Padrão de Temperatura Kaye IRTD. Inteligente IRTD 400; Kaye Humidity Calibrator. HygroCal100; Fique por dentro das novidades da Kaye. Receba o nosso KayeAlert! Siga-nos no Linkedin! ... 115 VAC 60 Hz, 3 A or 230 VAC
CTR-40 Liquid Calibration Bath - KAYE
El CTR-40 es un baño de temperatura portátil diseñado para satisfacer las necesidades de calibración y validación del sistema Kaye ValProbe.Combinado con el software IRTD y ValProbe, el CTR-40 proporciona calibraciones / verificaciones de ValProbe para el sensor de temperatura ValProbe.
Kaye LabWatch IoT
Internal sensor range: -20 to +60°C (Accuracy of 0.6°C from 0 to 45°C) External sensor range: -196 to +200°C (Accuracy of 0.1°C from 0 to 60°C) Maximum cable length of external sensor is 30 feet/9 meters: Relative Humidity: Internal or External sensor range: 0 to 100% RH (Accuracy of 2% from 10 to 90% at 25°C) Auxiliary Inputs
Kaye Validator AVS
El AVS (Sistema de Validación Avanzada) de Kaye Validator combina mediciones precisas de sensores con todos los requisitos de GMP para calibración y trazabilidad a los estándares nacionales, al tiempo que genera informes compatibles y administra los activos validados y el equipo de validación.El Validator AVS ofrece características de hardware mejoradas, un concepto de manejo de datos ...
Combineurs compacts PRO-HDAR450-2 - AMPHENOL PROCOM
400 - 420 MHz = 1 415 - 435 MHz = 2 430 - 450 MHz = 3 445 - 465 MHz = 4 460 - 480 MHz = 5: Exemple de référence ; PRO-HDAR450-2: H: H ... Hybrid Combiners by Amphenol Procom for Tx 35-100 W in frequency range 60-1000 MHz. Standard products are 2 to 8 channels. Learn more. Explorez tousCombineurs hybrides.
Dipole Arrays S.M4-445-OM - amphenolprocom.com
4-stack dipole phased array 420 - 470 MHz omni: S.M4-445-OM: 420 - 470 MHz: Add to quote: Related products. ... RF Cavity Combiners by Amphenol Procom for Tx 150-300 W radio systems in 60-500 MHz. Standard products are 2 to 8 channels. Read more here. Explore all Cavity Combiners.
Compact Combiners PRO-HDAR450-3 - AMPHENOL PROCOM
405 - 420 MHz = 2 415 - 430 MHz = 3 425 - 440 MHz = 4 435 - 450 MHz = 5 445 - 460 MHz = 6 455 - 470 MHz = 7 465 - 480 MHz = 8: Naming Example ; PRO-HDAR450-3: H: H ... Hybrid Combiners by Amphenol Procom for Tx 35-100 W in frequency range 60-1000 MHz. Standard products are 2 to 8 channels. Learn more. Explore all Hybrid Combiners.
Whip Antennas MU 11-X/... - AMPHENOL PROCOM
Encapsulated phasing coil. Black-chromed, stainless steel whip. Choice between general purpose tunable models. Stainless steel X-mount with M6-thread whip-fastening system.
Kaye RF ValProbe Loggers
HTR-420; HTR-400; Bain Kaye CTR. CTR-25 ; CTR-40; CTR-80; Le comparateur d'azote liquide; Sonde Kaye IRTD. ... Température interne: plage -20 ° C à 60 ° C, précision 0,5 ° C; Température externe: plage -200 ° C à 200 ° C, précision 0,1 ° C à 0,3 ° C; Autonomie de la batterie: +/- 2 ans;
KAYE IRTD 400 I Temperature Reference Standard | KAYE
The broad temperature ranges from Ultra Low Temperature (-196°C) to High Temperature (+420°C), enables it to be used in virtually all temperature validation applications. ... Ambient Temperature Range: 0 to 60°C (32 to 140°C) Humidity 0 to 95% non condensing: Dimensions: Overall length 603mm (23.75") Grip: 89mm x 32mm (3.5" x 1.25")
CTR-25 Liquid Calibration Bath - KAYE
HTR-420; HTR-400; Kaye CTR Liquid Baths. CTR-25 ; CTR-40; CTR-80; LN2 Comparator; Kaye IRTD Temperature Standard. IRTD 400 Intelligent ; Kaye Humidity Calibrator. HygroCal100; Environmental Monitoring. Environmental Monitoring {Overview} Software/Services. ... 115V - 50 or 60 Hz / 230V - 50 or 60Hz:
PRO-ISO-PHY-TETRA-S6
Rx : 420 - 425 MHz: Type: TETRA combiner: Max. Input Power: 25 W / station: Insertion Loss Tx-Ant. 13 dB: Insertion Loss Rx-Ant. 13 dB: Isolation TRx - TRx: Tx - Tx : > 60 dB ... Hybrid Combiners by Amphenol Procom for Tx 35-100 W in frequency range 60-1000 MHz. Standard products are 2 to 8 channels. Learn more. Explore all Hybrid Combiners.
PRO-PHY450-4-380-410-VSWR - AMPHENOL PROCOM
420 x 182 (incl. connector) x 42 mm / 16.53 x 7.17 (incl. connector) x 1.65 in. Weight: Approx. 1.9 kg / 4.19 lb. Environmental; Operating temperature range ... RF Cavity Combiners by Amphenol Procom for Tx 150-300 W radio systems in 60-500 MHz. Standard products are 2 to 8 channels. Read more here. Explore all Cavity Combiners.
CTR-40 油槽 - KAYE
115V 60 Hz. 230V 50 Hz. 约1,400 W. 单次最多放置RT直式无线记录器数量 ... HTR-420; HTR-400; Kaye低温油槽系列 ...
CTR-80 Ultra Low Temperature Bath - KAYE
Le bain CTR-80 est l'unité idéale pour l'étalonnage des capteurs de température utilisés dans les lyophilisateurs, les congélateurs et les unités à cryo ultra-basse. Fonctionnant de -80 à 30 ° C, le CTR-80 apporte une réponse rapide et une grande stabilité à vos applications de températures froides. Le CTR-80 surpasse tous les autres bains à basse température de sa catégorie.
KAYE IRTD 400 I Temperature Reference Standard | KAYE
The broad temperature ranges from Ultra Low Temperature (-196°C) to High Temperature (+420°C), enables it to be used in virtually all temperature validation applications. ... Ambient Temperature Range: 0 to 60°C (32 to 140°C) Humidity 0 to 95% non condensing: Dimensions: Overall length 603mm (23.75") Grip: 89mm x 32mm (3.5" x 1.25")
Amphenol
40-60 Delaware Avenue Sidney, New York 13838-1395 Website: www.amphenol-aerospace.com 21-033470-111 (PIN) 21-033471-111 (SOCKET) black insulator keyway to its right will be positioned adjacent to and in alignment with the outer contact’s orientation
PRO-ISO-PHY-TETRA-S2
The PRO-ISO-PHY-TETRA-S2 combiner provides the possibillity of connecting up to two TETRA radios into one common antenna. The PRO-ISO-PHY-TETRA-S2 models are available in the frequency range 380 - 470 MHz (on request).