Search Results for pt02c-20-41px003
Model 4103-02A | PCB Piezotronics
Model 4103-02A:PCB L&T Torque Sensor, Rotary Transformer, Shaft to Shaft, 200 in-lb Capacity FS, 15k RPM Max., MS Conn.
Thermometrics Glass Encapsulated NTC Chip - amphenol-sensors.com
20.86 BETA 25/125 RATIO 25/125 2935 11.85 3192 14.71 3620 21.10 3948 27.82 4072 30.88 4268 36.43 4410 41.05 4548 46.11 BETA 37.8/104.4 RATIO 37.8/104.4 2938 5.30 3197 6.14 3624 7.83 3949 9.42 4074 10.11 4269 11.29 4413 12.25 4551 13.25 R-vs-T Curve Material System: Temperature °C GC1 A GC2 A GC3 A GC4 F GC9 B
TRIAXIAL ICP® ACCELEROMETER Revision: R Optional versions have ... - PCB
Excitation Voltage 20 to 30 VDC 20 to 30 VDC Constant Current Excitation 2 to 20 mA 2 to 20 mA Output Impedance ≤ 200 Ohm ≤ 200 Ohm Output Bias Voltage 8 to 12 VDC 8 to 12 VDC Discharge Time Constant 0.6 to 2.0 sec 0.6 to 2.0 sec Settling Time(within 10% of bias) <5 sec <5 sec Spectral Noise(1 Hz) 150 µg/√Hz 1472 (µm/sec2)/√Hz [1]
LOAD CELL, PEDAL FORCE - PCB
[2]Calibrated at 10 VDC, usable 5 to 20 VDC or VAC RMS. [3]Over compensated operating temperature range. [4]FS - Full Scale. SUPPLIED ACCESSORIES: Model 100-10148-60 Hose Clamp (2) Model 100-10192-90 Nylon Velcro Strap - 12" Long Red (2) Model 52110-001200 Rubber Pads - Round Top (25) Model 52110-003500 Rubber Pads - Square Top (25)
Thermo-Trex® 200-HD Multi-Conductor Cable - TPC Wire
Thermo-Trex® 200-HD Multi-Conductor Cable is a high-temperature cable for power, instrumentation, and control applications that can withstand a maximum conductor temperature of 200°C / 392°F.
ICP® PRESSURE SENSOR - PCB
Excitation Voltage 20 to 30 VDC 20 to 30 VDC Constant Current Excitation 2 to 20 mA 2 to 20 mA Output Impedance < 100 Ohm < 100 Ohm Output Bias Voltage 8 to 14 VDC 8 to 14 VDC Physical Sensing Element Quartz Quartz Housing Material 304L/316L Stainless Steel 304L/316L Stainless Steel Thread Adaptor Material 316L Stainless Steel 316L Stainless Steel
Velocity loop powered sensors with dynamic vibration output
internal buffered amplifier and requires that the 4-20 mA loop be powered. x (4-20 mA output type) yy (4-20 mA full scale) z (dynamic scale) R = RMS output, velocity P = equivalent peak output, velocity 05 = 0.5 ips 10 = 1.0 ips 20 = 2.0 ips 30 = 3.0 ips 50 = 5.0 ips A = acceleration 100 mV/g V = velocity 100 mV/ips
REVISIONS PD-4420 NR - PCB
7 20-005320 ICPD Rubber Band2 2 8 20-003958 BIVAR PLP2-250 Light Pipe 1 9 DWP316K-ND Heat shrink with epoxy 3/16" cut to 1" 1 10 EPS2014-ND Heat Shrink 1/4" cut to 1.5" 1 11 EPS2014-ND Heat Shrink 1/4" cut to 2" 1 PD-4420 DWG. NO. SCALE: 2:3 CHECKED PRODUCTION PD-4420 ICPD OUTLINE DRAWING
Intrinsically safe 4-20 mA loop powered sensors
20 VDC 400 Ω 1/4 watt 24 VDC 600 Ω 1/2 watt 26 VDC 700 Ω 1/2 watt V DC power – 10 V 20 mA MIL-C-5015 2 PIN CONNECTOR Ø1.12 Ø.94 1/4-28 MOUNTING THREADS 2.12 2.77. Created Date:
SSI Technologies, LLC
7/16-20 7/16-20 Female 7/16-20 Snubber Metric Available Upon Request A B U z w Notes: l) This number wi always be at least a two digit number. Example: 5 = 05, 10, 50, etc. 2) Absolute transducers are calibrated to have the 0.5 Vdc, I Vdc, or 4 mA respectively at 0 PSIA 3) Not all combinations are available. Check with SSI before ordering.
Technical features - rfstechnologies.com
F/B at +/-30deg Total Power dB 20.2 23.2 23.8 First Upper Side Lobe Suppression dB 17.7 17.3 17.4 Electrical Downtilt Deg 2 to 12 Cross Polar Isolation dB 26 Interband Isolation dB 26 VSWR - 1.5 Passive Intermodulation (3rd Order, 2 x 43dBm) dBc -153 Maximum Effective Power per Port Watt 250 PRODUCT DATASHEET APXVBB3L20H2_43-C-I20S
Model 339B32 Triaxial ICP® Accelerometer Installation and ... - PCB
Constant Current Excitation 2 to 20 mA 2 to 20 mA Output Impedance ≤ 200 Ohm ≤ 200 Ohm Output Bias Voltage(Room Temperature) 7 to 12 VDC 7 to 12 VDC Discharge Time Constant 0.5 to 2.0 sec 0.5 to 2.0 sec Settling Time(within 10% of bias) <1.5 sec <1.5 sec Spectral Noise(1 Hz) 1187 µg/√Hz 11,644 (µm/sec2)/√Hz [1]
MODELS 137B2XB, 137B2XA, 137B25 - PCB
pcb.com | 1 800 828 8840. MODELS . 137B2XB, 137B2XA, 137B25. QUARTZ, FREE-FIELD, ICP ® BLAST PRESSURE PENCIL PROBE n One-piece design improves alignment n Micro-second rise time n 400 kHz resonant frequency n Two pressure outputs in one probe TYPICAL APPLICATIONS. n. Air Blast Measurement
TRIAXIAL ICP® ACCELEROMETER - pcb.com
Excitation Voltage 20 to 30 VDC 20 to 30 VDC Constant Current Excitation 2 to 20 mA 2 to 20 mA Output Impedance ≤ 200 Ohm ≤ 200 Ohm Output Bias Voltage 8 to 14 VDC 8 to 14 VDC Discharge Time Constant 0.1 sec 0.1 sec [1] Settling Time(within 10% of bias) < 1 sec < 1 sec Electrical Isolation(Case) > 108 Ohm > 108 Ohm Physical
Model 209C01 | PCB Piezotronics
Model 209C01:Miniature ICP® force sensor, 1 sec DTC, 2.2 lb comp., 2200 mV/lb
Model 356A16 Platinum Stock Products; Triaxial, high sensitivity ... - PCB
Excitation Voltage 20 to 30 VDC 20 to 30 VDC Constant Current Excitation 2 to 20 mA 2 to 20 mA Output Impedance ≤ 200 Ohm ≤ 200 Ohm Output Bias Voltage 8 to 12 VDC 8 to 12 VDC Discharge Time Constant 1.0 to 3.0 sec 1.0 to 3.0 sec Settling Time(within 10% of bias) <10 sec <10 sec Spectral Noise(1 Hz) 40 µg/√Hz 392 (µm/sec2)/√Hz [1]
AT&T Approved Charles CFDP Vault Mounted FTTP Pedestal Solution
AT&T Approved Charles CFDP Vault Mounted FTTP Pedestal Solution INNOVATIVE ENCLOSED SOLUTIONS™ Charles Industries, Ltd. Phone: (847) 806-6300 Fax: (847) 806-6231 Web: www.charlesindustries.com
Model 003P20 Hammer Kit consisting of 086C03 (1) 353B16 (1 ... - PCB
Model 003P20 Hammer Kit consisting of 086C03 (1) 353B16 (1) 080A90 (1) 003P20 (1) 001A11 (1) Installation and Operating Manual For assistance with the operation of this product,
TRIAX ICP® SEAT PAD ACCELEROMETER PER ISO 10326-1 Revision: C - PCB
Spectral Noise(1 kHz) 2 µg/√Hz 20 (µm/sec2)/√Hz [1] Physical Sensing Element Ceramic Ceramic Sensing Geometry Shear Shear Housing Material Titanium Titanium Sealing Hermetic Hermetic Size (Diameter x Width) 7.87 in x 0.472 in 200 mm x 12 mm Weight 9.6 oz 272 gm [1]
ICP® PRESSURE SENSOR - PCB
Model Number 102B06 ICP® PRESSURE SENSOR Revision: E ECN #: 54949 Performance ENGLISH SI Measurement Range(for ±5V output) 500 psi 3,450 kPa Useful Overrange(for ± 10V output) 1,000 psi 6,895 kPa [1]