Search Results for sr04m-2 ultrasonic sensor mode
Data Sheet R-Series V RP5 SSI - Temposonics
Update rate 2 Stroke length 25 mm 300 mm 750 mm 1000 mm 2000 mm 6350 mm Update rate 10 kHz 3.4 kHz 2.7 kHz 2.1 kHz 1.2 kHz 0.4 kHz Linearity deviation3 Stroke length ≤ 400 mm > 400 mm Linearity deviation ≤ ±40 μm < ±0.01 % F.S. Optional internal linearization: Linearity tolerance (applies for the first magnet for differential measurement)
M107 200M MINI ALTIMETER KIT, 200kHz, SMART - AIRMAR EMEA
The sensor is available in either 170 kHz or 200 kHz. With low power consumption of just 150 mA at 12 V, the 200m Mini Altimeter is perfect for power-limited vessels. Optional water temp sensor available. In full auto mode, the sounding rate is variable with depth; in manual mode, the sounding rate is configurable to run up to 10X per second.
Data Sheet R-Series V RF5 Analog (document part number: 552206)
The Temposonics® R-Series V brings very powerful sensor performance to meet the many demands of your application. The RFV sensor is the R-Series V with improved fl exible sensor rod. The main advantages of the fl exible sensor rod are: Straight and curved line The fl exible sensor rod enables position measurement on straight and also curved line.
Temposonics
Shock test 100 g (single shock) IEC standard 60068-2-27 Vibration test 5 g / 10…2000 Hz IEC standard 60068-2-6 (resonance frequencies excluded) EMC test Electromagnetic emission according to EN 61000-6-3 Electromagnetic immunity according to EN 61000-6-2 The sensor meets the requirements of the EC directives and is marked with .
Flow Transducers - Precise and Reliable Industrial Ultrasonic Flow ...
Airmar’s ultrasonic flow transducers provide reliable, maintenance-free measurement for monitoring systems that measure the flow or velocity rates of fluids such as water, wastewater and fuel that move through pipes, rivers or open channels. Safe, compact and rugged, Airmar’s wide variety of ultrasonic flow transducers range from models optimal for hostile and chemically aggressive ...
Absolute, Non-Contact Position Sensors Operating Manual MH Series ...
12 / 24 VDC 2 1 GND 3 3 CAN_HI 4 4 CAN_LO 5 2 n.c. 1 5 Fig. Core output of MH sensors CANbus Detailed information on the mechanical installation of the sensor into the mobile hydraulic cylinder is given in the instal-lation manual. During installation, make sure that cables are located correctly inside the cylinder. The cables must not
SENSOR SELECTOR GUIDE - Temposonics
The MHRM sensor has been developed especially for railway appli-cations and extends the portfolio of the Temposonics® MH-Series sensors. It is compliant with EN 50121-3-2 and meets the special requirements for shock according to EN 61373 Cat2 (Bogie) and Cat3 (Axle), vibration according to IEC 60068-2-64 Fn Cat3 (Axle)
Spread Sensors Pro - marport.com
2), the starboard clump sensor (3) and the starboard sensor (4) to know the distance with each one. Then, it sends the three distances (yellow A, B, C) to the receiver. • The port clump sensor (2) listens to the answer of the starboard clump sensor. Then, it . sends the distance between them (blue A) to the receiver. • The starboard clump ...
Data Sheet R-Series V RH5 PROFINET (Document part number: 551962)
6 Temposonics® R-Series V RH5 PROFINET IO RT & IRT Data Sheet TECHNICAL DRAWING Fig. 2: Temposonics® RH5 with ring magnet RH5-M/S-A/V – RH5 with threaded fl ange M18×1.5-6g or ¾"-16 UNF-3A, example: Connection type D58 (connector outlet) MS/ER NS/RN 1 4 5 2 1 4 5 2 17 (0.67) Sensor electronics housing
Data Sheet E-Series EH Analog - Temposonics
I 2 I Temposonics® E-Series EH Analog Data Sheet 4 5 3 1 Measurement cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter 5 Time-of-fl ight converted into position Sensing element (Waveguide)
T RSERIES - Temposonics
DIN EN 50081-1 (Emissions), DIN EN 50082-2 (Immunity) Shock Rating: 100 g (single hit)/IEC standard 68-2-27 survivability Vibration Rating: 5 g/10-150 Hz/IEC standard 68-2-6 PROFILE STYLE (RP MODEL) Electronic Head: Aluminum die-cast housing Sensor Stroke: Aluminum profile Sealing: IP 65 Mounting: Adjustable mounting feet or T-slot M5 nut in ...
Model 221B02 Link ICP® quartz force sensor, 100 lb comp., 100 lb ... - PCB
Figure 2 summarizes a complete 2 -wire ICP system configuration. Figure 2 Typical ICP Sensor System. In addition to ease of operation, ICP force sensors offer significant advantages over charge mode types. Because of the low impedance output and solid-state, hermetic construction, ICP force sensors are well suited for continuous, unattended
Resources > Videos > Sensor Selection Made Easy - PCB
Dual Mode Charge Amplifiers; Digital ICP®-USB Signal Conditioner; Cables. General Purpose Coaxial; Low Noise Coaxial; ... 2-Socket Connectors; 3-Socket Connectors; 4-Socket Connectors; M12 Connectors; BNC Connectors; ... > Sensor Selection Made Easy.
Model 132A36 Micro ICP® pressure sensor, 140 mV/psi, 1/2-20 mtg ... - PCB
Micro ICP® pressure sensor, 140 mV/psi, 1/2-20 mtg thd (for high frequency Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com
SGX - SGX Sensortech Sensor
Head office. Switzerland, Courtils 1, 2035 Corcelles-Cormondreche +41 (0) 32 732 16 70. contact@sgxsensortech.com
Data Sheet MH-Series MH Analog - Temposonics
3 Temposonics® MH-Series MH Analog Data Sheet */ Resonance frequencies excluded **/ According to calculations under use of the FKM guideline Cycles Ø 7 mm sensor rod Ø 10 mm sensor rod Dynamic pressure: < 2 × 106 pressure cycles 300 bar 350 bar Static pressure: < 2 × 104 pressure cycles 400 bar 450 bar Proof pressure: Maximum 5 minutes testing time for cylinder pressure test 525 bar 625 bar
Acu-Trac Smart 485 Family Overview - Amphenol Sensors
A deadband is an area of a signal range where the ultrasonic sensor cannot detect an object ... face of the part as shown in Figure 2. In the table output mode, the user sets up a look up table in the transducer. This mode of operation is typically used to set up a non-linear gauge or tank. The user would enter the distance and output settings
Particulate Matter Sensor - Amphenol Sensors
Through-shaft, end-of-shaft 2-piece and ARC/offaxis configurations; ... Ultrasonic Fluid Level Sensors. Continuously monitors liquid levels within tank or reservoir, including fuel, coolant and hydraulic fluids. ... Custom sensor packaging Current Sensors. Measure and monitor current flowing to and from battery.
Data Sheet R-Series V RM5 EtherNet/IP - temposonics.com
2 Temposonics® R-Series V RM5 EtherNet/IP™ 5 3 1 Measurement cycle 1 Current pulse generates magnetic fi eld 2 Interaction with position magnet fi eld generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter 5 Time-of-fl ight converted into position Sensing element (waveguide) Position magnet (magnetic fi eld)
200WX WeatherStation® Instrument - Airmar
The WeatherStation 200WX is the best choice for mobile, weather-monitoring applications. Sensor rich, in a durable, rugged, small housing that is IPX6 rated, means the 200WX can be used on moving platforms such as TV-news and military vehicles. Knowing the dynamic true wind speed and direction is important and often mission-critical.